Scan QR code here download and install APP Android App Store Manual Instructions
WIFI Alarm System 01 Content 1、Technical Parameters.................................................................................................. 3 1.1 Dimension drawing............................................................................................... 3 2、Features.................................................................................................................... 4 3、Daily Operaion Nouns........................................................................................
02 WIFI Alarm System WIFI Alarm System 1. Technical Parameters 12.4 Remote SMS query of parameter set.................................................................... 19 2 12.4.1 Query system setting................................................................................ 19 2 12.4.2 Query system setting2.............................................................................. 19 2 12.4.3 Query alarm phone number setting........................................................... 20 2 12.4.
04 WIFI Alarm System 2. Features WIFI Alarm System 3. Daily Operation Nouns Built-in powerful performance CPU master based on 32-bit Cortex-M3 core ARM: set security task (Anti-burglar), make the host into alert state, also known as Based on uCOS - III operating system multitasking design, with a great user Arming, Alert or Booting. operation experience. WIFI/GSM/GPRS network alarm system, and support APP push/SMS/voice monitoring/center network etc.
06 WIFI Alarm System 4. Panel Indicator Lights WIFI Alarm System 5. Side Panel Jacks and Function keys ARM STA1 STA2 USB 5V S2 MICRO-SIM 6. Buzzer NOTES S1 WIFI/ INIT LEARN 3 groups of indicators display the Arm/Disarm/Alarm state, GSM signal state, WIFI state and working state. Fast flash: 0. 1s ON,0. 1s OFF; Slow flash: 0. 5s ON,0. 5s OFF; Pulse flash: flash every 5s for 0. 1s. NOTES Long ringing: 0.5s sound, 0.
08 WIFI Alarm System 7.Use Beginning Inset SIM card: insert standard MICRO SIM card at slot according to the diagrams (should be trimmed with big SIM card); Card inserting is OK when there is a ‘tick’ sound. Power on: inert the main power supply at USB 5V jack to power the host. Booting: at shutdown state, click S1 button then loosen, 3 indicator lights on at the same time, booting OK. WIFI Alarm System 9.
10 WIFI Alarm System WIFI Alarm System 10.2 Control the host into learning state by S1 key First keep pressing button to choose the devices to be learnt, then loosen the button, enter learning state. Refer to below tablet: Device to be learnt 9.2 Mobile APP unbinding with host Keep pressing S2 button of the host five times then release, the WIFI light fast flashes 1 second, the host automatically terminates WIFI binding.
12 WIFI Alarm System As shown in the figures below: 10.4.2 Mobile APP controls the host to learn detectors Enter“System Settings" menu. Press "Detector Setting", enter the detector setup interface, APP would obtain the quantity of detectors already learnt with the host. Press the "Add Devices" button to enter the detector coding interface.
14 WIFI Alarm System WIFI Alarm System 10.4.3 Mobile APP controls the host to delete remotes learnt Keep pressing “Remote Controller” on its setting interface.(In IOS system, press “Delete” symbol) Dialogue window pops up, if user confirm to delete, press “OK”. App sends deleting commands to host APP returns to the remote setup interface, then obtains the quantity of remote controllers coded again. If deleted successfully, the quantity of remote controller would be zero.
16 WIFI Alarm System 12.Parameter Setting and Query User can set or quer y host parameters by SMS or mobile app 12.1 App query and parameter setting: function switch setting, alarm phone setting, entry delay setting WIFI Alarm System 12.2 Remote SMS setting of parameters Users only need to edit SMS with the following format and send to the host SIM number to complete the setting.
18 WIFI Alarm System Note:All examples below with default engineer password “6666” ( 1) Control host into learning status setting format A,B A is for setting detector name,“0-11” O-others, 1-gate, 2-hall, 3-SOS, 4-bedroom, 5-window, 6-balconies, 7- perimeter, 8-smoke, 9-gas, 10-carbon monoxide, 11-water leak.
20 WIFI Alarm System 12.4.3 Query alarm phone number setting WIFI Alarm System 13.User Daily Operation SMS format *6666*51* PHONE set: 1: 2: 3: 4: 5: REDIAL COUNTER: The user can operate the host at any way as follows: Operate by remote controller on site ? Remotely Sending SMS ? Remotely using a mobile phone APP ? Center Remote Control (valid only for GPRS network) ? 13.1 Arm Remote control operation: Press the remote control Out Arm key [ ].
22 WIFI Alarm System WIFI Alarm System 13.2 Stay Arm Remote control operation: press Arm key on the remote control at home [ 13.3 Disarm ]. Remote control operation: Press the [ ] button on the remote control to disarm. SMS Operation: Send SMS 1234zj , “1234” stands for the user's password. The host SMS Operation: Send SMS 1234cf , “1234” stands for the user's password. The host will reply to the controlling phone with a message saying "Stay Arm success!".
24 WIFI Alarm System WIFI Alarm System 13.4 SOS 14.Alarm and Remote Monitoring Remote control operation: Press the SOS button on the remote control [ SOS ]. The host supports multiple alarm types, when the alarm occurs, it would send the APP Operation: In the main menu, press the "SOS" icon.