G SM & iFW i larm A ystem S Us er anual M WIFI+GSM/3G+GPRS Android App Store Scan QR code here download and install APP
CONTENT Content Overall state 1~2 Explanation 1 Features 1 Identification for daily operation 2 Alarm host appearance and accessories 3~7 Top view 3 Bottom view 3 Side view 4 Keys of side face 4 Main interface 4 Description for main interface 5 Menu structure 6~7 Initial usage 8 Start 8 System initialization 8 Menu operation 8 Phone number setup 8 Add/Delete remote control 9 Add/Delete wireless detector(included doorbell alarm) 9 Add/Delete RFID card 10 Synchronizati
OVERALL STATE CONTENT Overall state Synchronize external wireless siren via APP 17 Inquire/set parameter: Set function switch, Set alarm phone, Set delay alarm 18 Remote SMS 19~21 Parameter setup 19 Alarm host name setup 19 Parameter inquiry 20 Inquire system setting 20 Inquire system setting2 20 Alarm phone setup inquiry 21 Delay setup inquiry 21 Switch setup inquiry 21 Remote control/detector/RFID card inquiry 21 Phone function 22 Daily operation 23~25 Out Arm 23 Stay Arm
OVERALL STATE Identification for daily operation Arm set security task (i.e. Anti-burglar), make the host into alert state, also known as Arming, Alert or Booting. Designate security guard mission(i.e. Anti burglar), set the alarm host into on-guard status, also called Arming , Alert or Power on.
ALARM HOST APPEARANCE AND ACCESSORIES ALARM HOST APPEARANCE AND ACCESSORIES Side view Description for main interface No SIM card Power on/off/Initialization key 3 GPRS networking indication GSM signal Microphone GSM signal indication Power jack Status bar Gray color means no signal, 1-5 level stands for GSM signal strength Wired siren jack SIM card slot 1 Key of side face Function Description Power on Press this key, “Welcome” appears in the screen, it means power on.
ALARM HOST APPEARANCE AND ACCESSORIES ALARM HOST APPEARANCE AND ACCESSORIES Menu structure Arm Beep Siren Setting Switch Arm SMS Keypad Lock MENU Backlight System Password User 简体中文 Log Set arm beep Select: On/Off, Default: Off Set Siren Select: On/Off, Default: On Set Arm/Disarm SMS Select: On/Off,Default: Off Set keypad to be locked or not Select: On/Off,Default: Off Set keypad backlight to be on or off Select: On/Off,Default: Off Phone 6 Learning new remote control Del Remoter Delete all
INITIAL USAGE INITIAL USAGE Initial usage Operation Keyboard: Main Menu Phone 1st Phone, enter into phone number setup menu. Press to select Number, input the alarm number (up to 18 digits), and press to backspace in case of error Press to select Dial, press to select On or Off.If "On" is selected, the panel will dial the alarm number when an alarm occurs. Press to select SMS, press to select On or Off.If "On" is selected, the alarm host will send SMS to this phone when an alarm occurs.
INITIAL USAGE Press confirm The alarm host displays "Synchronize" and enters into the 20- seconds countdown dialog window waiting for the wireless detector synchronization. Trigger the wireless detector to launch wireless signal to the alarm host. The alarm host displays "Learning OK", then the wireless detector is successfully added.
MOBILE PHONE APP MOBILE PHONE APP Mobile phone APP 4 5 The concerned APP description is based on Andriod system, some description may differs due to APP version or iOS system. All description is subject to installed APP in mobile phone. Install Using mobile phone’s browser to scan QR code, then download the APP and install. APP configuration with alarm host Ensure the alarm host and mobile phone to be in the same WiFi network.
MOBILE PHONE APP 1 MOBILE PHONE APP 2 3 1 2 3 1 2 3 4 5 4 5 6 Number of learnt remote control 1 2 3 Add detector via APP Enter into “System Settings” menu . Select “ Detector Setting”, all detectors are listed in this interface. Select “Add Devices”. Press “Detector Name” to select the added detector name. Press “Zone Mode” to select the arm mode. Select “Start to learn”. The alarm host will send successful information to APP, the learning is completed. “Learn OK” appears in APP.
MOBILE PHONE APP MOBILE PHONE APP 7 8 Delete detector via APP Enter into “Detector Setting” menu, press “ ”icon which you wan to delete . A window “Delete Detectors named....appears, click “OK” to finish deletion. APP returns to “Detector Setting” menu, the deleted detectors will not be listed in this interface. Refer to below diagram: 1 2 3 Number of learnt detector Delete remote control via APP Enter into “ Remote Setting ” and press “ ” icon.
REMOTE SMS MESSAGE MOBILE PHONE APP Inquire/set parameter: Set function switch; Set alarm phone; Set delay alarm Enter into System Setting Switch Setting, there are 3 options(Arming beep, Alarm beep, Arm/disarm SMS) to select On/Off accordingly. Enter into System Setting Alarm Phone Setting, click “ phone calling function when alarming, click “ ” icon to activate ” icon to activate SMS function when alarming.
REMOTE SMS MESSAGE REMOTE SMS MESSAGE Example: Set 2 alarm phone numbers as 13912345678 and 075581234567. 13912345678 is used to receive calling and SMS alarm, 075581234567 is used to receive calling alarm, then please set SMS contents according to below format: *6666*5113912345678,1,1*52075581234567,1,0* 3、Format of IP address: :aaa,bbb,ccc,ddd,xxxxx aaa,bbb,ccc,ddd is IP address, xxxxx is the port, separated with comma. Example: Set GPRS server IP address as 116.62.42.
PHONE FUNCTION DAILY OPERATION Phone function Daily operation In Main Interface, press key to make calling. Please operate according to the hint in this interface. Remote control, Keyboard, RFID card. The user can control the alarm host by any of following ways: Remote SMS. Mobile phone APP. GPRS alarm center. Out Arm 10086 10086 By remote control: press 【 】key to activate Out Arm. By keyboard: In Main Interface, press * to activate Out Arm.
DAILY OPERATION DAILY OPERATION Stay Arm 1 By remote control: Press key to activate Stay Arm. By keyboard: In Main Interface, press * key for twice to activate Stay Arm. By APP: In Main Menu, select “ ” icon. After around 3 seconds, Stay Arm mode is completed. The alarm host reminder: A reminding voice “System armed” will be heard, the Main Interface displays “Stay Armed”. If Arm/Disarm SMS switch is on,the preset phone 2 ARM/ will receive “System Stay Armed! ”SMS.
ALARM AND REMOTE MONITORING ALARM AND REMOTE MONITORING Alarm and remote monitoring Refer to below diagram: 1 The alarm host supports diverse alarm types. When alarm is triggered, it will send alarm SMS to the user’s mobile phone and push alarm message to APP, simultaneously send alarm message to GPRS alarm center and make calling to the user, then the user can do on-time monitoring and remote operation.
PACKING LIST TECHNICAL PARAMETER Specification Packing List Input voltage: DC5V(micro USB jack) Alarm host x1 Working current: <120mA Micro USB 5V/1000mA Power adapter x1 Standby current:<80uA Wireless PIR detector x1 Siren output:<500mA Door sensor x1 Wireless frequency: 433MHz Remote control x2 Wireless coding: EV 1527 RFID card x2 GSM bands: 850/900/1800/1900MHz Wired siren x1 WiFi standard: IEEE802.11b/g/n wireless standard Back up battery: 3.
Date: Mar.4th,2017 PG-103 Belinda 品 号 PG-103公司标准英文说明书V1.
1. Warning This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. NOTE: This device and its antenna(s) must not be co-located or operation in conjunction with any other antenna or transmitter. RF Exposure Statement To maintain compliance with FCC’s RF Exposure guidelines, This equipment should be installed and operated with minimum distance of 10mm the radiator your body.
The use of accessories that do not satisfy theserequirements may not comply with FCC RF exposure requirements, and should beavoided. The use of belt clips, holsters and similar accessories should not contain metallic components in its assembly. The use of accessories that do not satisfy these requirements may not comply with FCC RF exposure requirements, and should be avoided.