tLory User Guide Version: 1.
tLory User Guide Revision History Date of Revision Version April 25, 2019 1.0 Pages Revised Details of Revision All New Copyright 2018 SystemBase Co., Ltd. All rights reserved. Website http://www.sysbas.com/ Tel +82-2-855-0501 Fax +82-2-855-0580 16F (1601) Daerung Post Tower-1, 288, Digital-ro, Guro-gu, Seoul, Republic of Korea For inquiries, please contact us at tech@sysbas.
tLory User Guide This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
tLory User Guide Table of Contents 1. OVERVIEW ..................................................................................................................................... 5 2. FEATURE ......................................................................................................................................... 5 3. COMPONENTS .............................................................................................................................. 6 4. HARDWARE ......................
tLory User Guide 1. Overview tLory is a device that transmits temperature and humidity information through LoRa. It converts the data into LoRa signals and transfers them to devices that are several kilometers away. LoRa (wireless communication technology for sensor networks), the next generation communication technology of Low Power Wide Area (LPWA) capable of transmitting small amounts of data over long ranges, enables communications up to 10 km in open terrain. 2.
tLory User Guide 3.
tLory User Guide 4. Hardware 4.1 Specification CATEGORY SUBCATEGORY SPECIFICATION Frequency Band 917 ~ 923MHz Modulation LoRa Antenna -1.310 dBi Operating Temperature -40℃ ~ +85℃ Environment Humidity 5~95%, non-condensable Wireless Interface Power 3.
tLory User Guide 4.
tLory User Guide 5. How to Connect A device such as SLory or uLory is required to receive the information on temperature and humidity transmitted from tLory. Users should connect sLory or uLory to PCs and use LoryView to check the data on temperature and humidity from tLory. 6. How to Use Setting channel, Spreading Factor and power (output) of tLory is required to communicate with other devices in LoryNet via Dip Switch or LoryView.
tLory User Guide Channel ON ON OFF ON 2=917.9MHz ON ON OFF OFF 3=918.5MHz ON OFF ON ON 4=919.1MHz ON OFF ON OFF 5=919.7MHz ON OFF OFF ON 6=920.3MHz ON OFF OFF OFF 7=920.7MHz OFF ON ON ON 8=920.9MHz OFF ON ON OFF 9=921.1MHz OFF ON OFF ON 10=921.3MHz OFF ON OFF OFF 11=921.5MHz OFF OFF ON ON 12=921.7MHz OFF OFF ON OFF 13=921.9MHz OFF OFF OFF ON 19=923.1MHz OFF OFF OFF OFF ON ON ON ON 20=923.
tLory User Guide Button BUTTON DESCRIPTION Turn on the device with 1~6 switch on, RST Press and hold for more than 3 seconds to reset the device 6.2 Operation Mode Setting Users can change the communication setting of tLory with switch and detailed setting such as sensing cycle via LoryView. Setting tLory via LoryView requires a device such as sLory or uLory. Setting via Utility (LoryView) The utility provided along with tLory is available on http://www.sysbas.
tLory User Guide (*Automatic switch to the Sleep Mode after 1 minute) Hereafter, users can follow the setting process of (LoryView) for tLory. ※ Setting and entering ACK, users can retake the corresponding setting values, but resetting is required when the value is not returned which indicates that the setting is not normal. After setting, users should turn off the device, change channel and spreading factors according to the setting of LoRa, and turn it on again.
tLory User Guide ORDER DESCRIPTION 1 Set Channel, Spreading Factor with Dip Switch 2 Turn on Switch 7 to activate tLory 3 Set LoRa of sLory or uLory in the same way of setting LoRa of tLory 4 - Enter an interval unit in the entry 48 and sensing cycle in the entry 49 (Refer to the General Manuals for table maps rather than the Quick Manuals) * tLory is in the Sleep Mode except when it is sensing as it uses battery.
tLory User Guide to communicate with any ports and entries of other devices. All ports included in tLory have unique table maps.
tLory User Guide 7.1 Device Process Table Map Entry Size Name RW 0 1 Version R 1 1 Process Type R 2 1 Data Size R 3 1 FIFO size R 4 3 Privilege ID RW Range (Default) X : 1~15 Y : 0~15 0~4 (4) 0~16 (6) 1 = 16 Byte 1~255 (8) Description Firmware version of table (X.
tLory User Guide 94 2 Reserved R - 96 3 SID R 0~0xffffff Device number of another user 99 1 DTN R 0~0xff Table number of another user 100 1 Dent R 0~0xff Table entry address of another user 101 1 Size R 0~0xff Size of changed entry 102 2 Reserved - - 104 3 SID R 0~0xffffff Device number of another user 107 1 DTN R 0~0xff Table number of another user 108 1 Dent R 0~0xff Table entry address of another user 109 1 Size R 0~0xff Size of changed entry 110
tLory User Guide Display tLory firmware date 142 67 Update Data R/W 68Byte Record firmware update data 7.2 LoRa Port Process Table Map Entry Size Name RW 0 1 Version R 1 1 Process Type R 2 1 Data Size R 3 1 FIFO size R 4 3 Privilege ID RW Range (Default) X : 1~15 Y : 0~15 0~4 (0) 0~16 (1) 1 = 16 Byte 1~255 (16) Description Firmware version of table (X.
tLory User Guide 17 1 Mode R/W 0~2 (0) Transmission mode: 0=Slave, 1=CSMA, 2=Slave/CSMA LoRa Setup 18 1 Switch Flag R/W 0 ~ 1(0) Set 0 = Dip switch 1 = Value set in LoRa Table 19 29 Reserved 48 16 Reserved 64 16 Reserved 80 3 SID R 0~0xffffff Device number of another user 83 1 STN R 0x00~0xff Table number of another user 84 1 Dent R 0x00~0xff Table entry address of another user 85 1 Size R 0x00~0xff Size of changed entry 86 2 Reserved R - 88 3 SID R 0~0x
tLory User Guide 117 2 Rx Cnt, R 0~0xffff Number of rocket reception Entries indicating the initialization of each layer Bit 0: Application layer Bit 1: Table layer 119 1 Init R 1 Bit 2 : Route layer Bit 4: Link layer The bit 0 indicates that it is not initialized while the bit 1 means the completion of initialization.
tLory User Guide 0 = Ignore rockets 1~99 = Request to pass rockets to ports and to its final destination 8 3 DID RW 1~0xfffffe (0) 11 1 DTN RW 0~32 (0) 12 1 Dent RW 0~32 (0) 13 1 Port_Ea RW 0 ~ 32 (1) 14 34 Reserved Not used in tLory Number of sensor ports Interval unit: ASCII code 48 1 Scale RW 1~0xff (0x48) ‘D’(0x44)=day, ‘H’(0x48)=time, ‘M’(0x4D)=minute, ‘S’(0x53)=second 49 1 Interval RW 1~255 (1) 50 3 TH_DID RW 1~0xfffffe (0xfffffe) 53 1 TH_DTN RW 0~32 (3) D
tLory User Guide 109 1 Size R 0~0xff Size of changed entry 110 2 Reserved - - 112 1 Usage rates of FIFO input R 0~100 Usage rates of FIFO input (%) 113 1 Usage rates of FIFO output R 0~100 Usage rates of FIFO input (%) 114 1 Over_Cnt R 0~255 Number of FIFO overrun 115 2 Tx Cnt, R 0~0xffff Number of rocket transmission 117 2 Rx Cnt, R 0~0xffff Number of rocket reception Reserved space Entries indicating the initialization of each layer Bit 0: Application layer Bit 1: