sLAN/all-PoE User Manual Version 1.0.1 2021/03/04 www.sysbas.
sLAN/all-PoE User Manual Revision History Revision Date 2021.03.04 Document Pages Ver. Revised 1.0.
sLAN/all-PoE User Manual Contents 1. BEFORE USING------------------------------------------------------------------------------------------------------------- 5 2. COMPONENTS -------------------------------------------------------------------------------------------------------------- 6 3. PRODUCT -------------------------------------------------------------------------------------------------------------------- 7 4.
sLAN/all-PoE User Manual Please be sure to read this manual before using and use the product safely and accurately. • Pictures and photos in the manual may be different from the physical, and the document is subject to change without notice to improve performance. For the last information, please visit our website (www.sysbas.com). • To view frequently asked questions and answers, please visit our website and find Support –Technical Support – FAQ section.
sLAN/all-PoE User Manual 1. Before Using sLAN/all PoE is a small Ethernet converter which provides Ethernet wired communication and Power over Ethernet (PoE) for serial equipment supporting RS232/422/485. The communication standard supports IEEE 802.3 10/100 Base-TX, IEEE 802.3af. It is equipped with serial standard DB9 connector, providing easy-to-apply gateway function to RS232/422/485 compliant equipment. Maximum communication speed is 921.6Kbps for serial and 100Mbps for Ethernet.
sLAN/all-PoE User Manual 2.
sLAN/all-PoE User Manual 3. Product LED LED State Operation 1 RDY(Yellow) Blink 2 TXD (Green) Blink Flashes when serial data is transmitted. 3 RXD (Red) Blink Flashes when serial data is received. Turns ON briefly and then OFF when Power ON. Flashes when Booting is complete.
sLAN/all-PoE User Manual Connector Front Back (Micro USB Type ) Front: • Serial Port(DB9 Male): RS232/RS422/RS485 (Please refer to the APPENDIX for pin specifications) Back: • PWR: Micro USB Type B • LAN Port: This port(RJ45) is used to connect sLAN/all PoE to Ethernet card, hub, router and other wired networkconnected equipment. • RST: By pressing and releasing the button, sLAN/all PoE restarts.
sLAN/all-PoE User Manual 4. How to Use Please refer to “Chapter 6. Get Started” for instructions on how to set up. ① PC – Serial Equipment Connection For the most common example, the PC and sLAN/all PoE are connected to the network, allowing the PC to use serial devices connected to the sLAN/all-PoE. ② Serial Communication Tunneling By extending the serial cable between the PC and the serial equipment via the network, it can be used like a serial cable with no distance limit.
sLAN/all-PoE User Manual ③ COM Port Redirection By using Redirection, users can use the serial port of sLAN/all PoE connected to the network as if it were a PCmounted serial port.
sLAN/all-PoE User Manual 5. Get Started An Ethernet port is required to connect sLAN/all PoE to the network. Ethernet supports 10Mbps and 100Mbps Ethernet connections. The LAN port on sLAN/all PoE supports MDIX feature, which automatically recognizes Cross Ethernet Cable and Direct Ethernet Cable, so it does not matter which cable users connect. Connect one end of the cable to the sLAN/all PoE and the other to the network equipment. 6.
sLAN/all-PoE User Manual 12
sLAN/all-PoE User Manual 7. Settings Precaution for Web Access Web setting is not supported in the network environment below 10Mbps as shown below: Therefore, if you use the Web to change the settings, you must be in 100Mbps network environment or connect the integrated device to a PC as shown below. If it is difficult to set the environment, please use the SGConfig utility to set up the device. Please refer to the ‘Access’ part of the previous page when directly connecting and setting with the PC.
sLAN/all-PoE User Manual Network Setting Network Setting page will be displayed in the initial screen of the Web setting, which shows the Network information of the equipment as below: You can set network environments and network management in the Networking Setting page. Once you have changed the settings, you must press the [Submit] button to save the changed value and restart it through the [Reboot] menu to apply them to actual equipment operation.
sLAN/all-PoE User Manual Operation Setting You can set the operating mode and network socket options in the Operation Settings page. Once you have changed the settings, you must press the [Submit] button to save the changed value and restart it through the [Reboot] menu to apply them to actual equipment operation. If you exist without saving the changes, the changed value will be lost.
sLAN/all-PoE User Manual Menu Default Description When UDP packets are received to the socket number waiting for a connection, data is sent to the serial port, and data entered into the serial port is made into UDP packets and sent to the Client. UDP Client When data is entered into the serial port, sends UDP packets to the IP and socket number of the set server. Set the IP and port number of the server to which you want to request access at [Target IP/Port]. Local Port 4001 Target IP 0.0.0.
sLAN/all-PoE User Manual Serial Setting You can set the operating environment for serial ports in the Serial Settings page. Once you have changed the settings, you must press the [Submit] button to save the changed value and restart it through the [Reboot] menu to apply them to actual equipment operation. If you exist without saving the changes, the changed value will be lost.
sLAN/all-PoE User Manual Menu Default Stop Bits 1 Parity No Description Set the number of stop bit (Option: 1, 2) Set the parity check method (Option: No, Odd, Even) Set the flow control method When the RTS/CTS option is selected, the RTS signal line is automatically Flow Control None controlled according to the incoming serial data flow, and the serial data transmission is automatically controlled according to the CTS signal line status. This function only works in RS-232 interface.
sLAN/all-PoE User Manual 8. Settings Using Utility Search When you run SGConfig and click Search, it will discover the sLAN/all PoE connected to the network. When you select the list of devices discovered in the list that you want to set up and click Configure, a window appears to set up sLAN/all-PoE as shown below. Setting Select the device you want to set up among the discovered devices and click [Configure].
sLAN/all-PoE User Manual ------------------------------- APPENDIX ---------------------------1.
sLAN/all-PoE User Manual 2. Serial Port Pin Assignment Pin No.
sLAN/all-PoE User Manual 3.
sLAN/all-PoE User Manual 5.
sLAN/all-PoE User Manual 6. Specification Ethernet 10/100Mbps RJ45 Port x 1 LAN Port Static IP, Dynamic IP Protocol TCP, UDP, ICMP, DHCP, HTTP, IPv4 Power over Ethernet(PD) IEEE 802.3 10/100 Base-TX , IEEE 802.3af Serial Port 1port DE-9 Male Interface RS232/422/485 Maximum Communication Speed 921.
sLAN/all-PoE User Manual Ordering Information sLAN/all PoE Package sLAN/all(Micro-USB) sLAN/all PoE, LAN cable, Ejector pin 25
sLAN/all-PoE User Manual 7. Trouble Shooting This part suggests solutions to various problems that may arise when using the equipment. Installation If you cannot access the equipment connected via sLAN/all PoE, it is recommended to check the network connection and cables first. Ensure all connections are properly made(Ethernet, DB9 connector, serial cable and so on). Check both the IP address and port number are entered correctly.
sLAN/all-PoE User Manual 8. Certification • KC Number: R-R-STB-sLANallPoE Test Item: KN 61000-4-2, KN 61000-4-3, KN 61000-4-4, KN 61000-4-5, KN 61000-4-6, KN 61000-4-11 Copyright Copyright ⓒ 2021 SystemBase CO., Ltd. All rights reserved. This manual is a document protected by Copyright law. Unauthorized copying, duplicating, publishing of some or all of contents without prior consent from SystemBase is against Copyright Law. www.sysbas.
If you have any inconvenience while using the product, please contact us. Email: Working Hour • Purchase/Quotation: overseas@sysbas.com MON ~ FRI 9:00 ~ 18:00 • Technical Support/RMA: tech@sysbas.com www.sysbas.com Tel: +82-2-855-0501 Fax: +82-2-855-0580 Copyright ⓒ 2021 SystemBase Co., Ltd. All Right Reserved.