© Copyright Systemair A/S, Denmark All rights reserved Systemair A/S, Denmark reserves the right to alter their products without notice. This also applies to products already ordered, as long time as it does not affect the previously agreed specifications. Only the English version is valid in case of a dispute. Translated versions are not valid in case of disputes.
Contents A B C D E F Commissioning record .......................................................................................................................1 Notes and signatures.........................................................................................................................1 Function settings ..............................................................................................................................2 C.1 Airflow..............................................
Commissioning record | A Commissioning record Company: Responsible: Customer: Date: Installation/Project: Installation address: Object/Unit: Model/Size: Item no.: Serial no: Access Software version: Time and date set: B Notes and signatures Signature: Printed name: Location: Date: Phone no.: 90925501 | Operator password: 1111 Service password: 0612 Operator password changed: Service password changed: Weekly program set: External connections (sensors, dampers, external alarm etc.
2 | Function settings C Function settings C.
Function settings | Fan compensation curves (configuration) Curve 1 □ Curve 2 □ Curve 3 □ Fan level All levels Low speed Normal speed High speed Low + Normal speed Normal + High speed All levels Low speed Normal speed High speed Low + Normal speed Normal + High speed All levels Low speed Normal speed High speed Low + Normal speed Normal + High speed Mode All modes When defrosting All modes When defrosting All modes When defrosting Fan Supply + Extract Supply Extract Supply + Extract Supply Ext
4 | Function settings Function Default setting Set value If outdoor comp. temp. control Outdoor temp/setpoint Curve point 1, 2, 3, 4: -20 / 22 °C ° 5 / 20 °C ° 20 / 20 °C ° 30 / 22°C ° If cascade control: Min supply air temp. limit 15 °C ° Max supply air temp. limit 28 °C ° Cooling recovery Mode ⊠ On □ Off Start at temp.
Function settings | Function Default setting Set value Freeze protection Type of freeze protection □ None □ Temp. sensor □ Guard □ Temp. sensor + guard None Temp. sensor Guard Temp.
6 | Function settings Function Default setting Free cooling □ No □ Yes Running when day outdoor temp. is above: 22 °C °C Stop when night outdoor temp. is above: 18 °C °C Stop when night outdoor temp. is below: 10 °C °C Stop when room temp.
Function settings | Function Default setting Exchanger defrosting mode □ None □ Temperature monitoring □ Pressure monitoring □ Sectional defrosting None Temperature monitoring Pressure monitoring Section defrosting Temperature monitoring defrosting □ On □ Off On Off Temperature sensor □ Exhaust air temperature □ Defrostning sensor Exhaust air temperature Defrosting sensor Temperature min limit -3°C °C Stop supply air fan if outdoor temp <–25°C °C Hysteresis to end defrosting -4°C °C Pres
8 | Function settings Function Default setting Fire function □ No □ Fire □ Smoke □ Fire + smoke No Fire Smoke Fire + smoke Operation mode when fire alarm ⊠ Stopped □ Continuous run □ Only supply air fan □ Only extract air fan □ Running via normal start/stop conditions Stopped Continuous run Only supply air fan Only extract air fan Running via normal start/stop conditions Supply air fan setpoint type ⊠ Auto □ Low □ Normal □ High Auto Low Normal High Extract air fan setpoint type Default value □
Setting the weekly program | D Setting the weekly program Factory setting of the fan speed are: • High fan speed 00:00 to 00:00 Monday to Sunday and Holiday. • Normal fan speed 07:00 to 17:00 Monday to Friday, 00:00 to 00:00 Saturday to Sunday and Holiday. • Low fan speed 00:00 to 00:00 Monday to Sunday and Holiday. • Settings of 00:00 to 00:00 stops the unit. E.g. changing low fan speed setting from 00:00-24:00 to 00:00-00:00 will stop the unit outside the time of normal fan speed.
10 | I/O Allocation E I/O Allocation Note any changes from the factory default input and output allocation configuration. Fill in any related information in the comment field. E.g. a pressure sensors measuring range, a contact’s polarity or similar.
I/O Allocation | Analog inputs Function Comment Function Comment Function Comment Function Comment AI1 AI2 AI3 AI4 AI5 AI6 AI7 AI8 AI9 SA DPT Pressure 1 Pressure 2 UI1 UI2 EA DPT Pressure 1 Pressure 2 UI1 UI2 Universal inputs UI1 UI2 UI3 UI4 90925501 | 11
12 | Alarm configuration F Alarm configuration Alarm settings Def.
Alarm configuration | Alarm settings Def.
14 | Alarm configuration Alarm settings Def.
Alarm configuration | Alarm settings Def.
16 | Alarm configuration Alarm settings Def.
Alarm configuration | Alarm settings Def.
18 | Alarm configuration Alarm settings Def.
Alarm configuration | Alarm settings Def.
20 | Alarm configuration Alarm settings Def.
Alarm configuration | Alarm settings Def.
22 | Alarm configuration Alarm settings Def.
Alarm configuration | Alarm settings Def.
24 | Alarm configuration Alarm settings Def.
Alarm configuration | Alarm settings Def.
26 | Alarm configuration Alarm settings Def.
Alarm configuration | Alarm settings Def.
28 | Alarm configuration Alarm settings Def.
Alarm configuration | Alarm settings Def.
30 | Alarm configuration Alarm settings Def.
Alarm configuration | Alarm settings Def.
32 | Alarm configuration Alarm settings Def.
Alarm configuration | Alarm settings Def.
34 | Alarm configuration Alarm settings Def.
Alarm configuration | Alarm settings Def.
36 | Alarm configuration Alarm settings Def.
Alarm configuration | Alarm settings Def.
38 | Alarm configuration Alarm settings Def.
Alarm configuration | Alarm settings Def.
40 | Alarm configuration Alarm settings Def.
Alarm configuration | Alarm settings Def.
42 | Alarm configuration Alarm settings Def.
Alarm configuration | Alarm settings Def.
44 | Alarm configuration Alarm settings Def.
Alarm configuration | Alarm settings Def.
46 | Alarm configuration Alarm settings Def.
Alarm configuration | Alarm settings Def.
48 | Alarm configuration Alarm settings Def.
Alarm configuration | Alarm settings Def.
50 | Alarm configuration Alarm settings Def.
Alarm configuration | Alarm settings Def.
52 | Alarm configuration Alarm settings Def.
Alarm configuration | Alarm settings Def.
54 | Alarm configuration 90925501 |