Fans | Air Handling Units | Air Distribution Products | Air Conditioning | Fire Safety | Air Curtains and Heating Products | Tunnel Fans DVU-HP Integrated Reversible Heat Pump System
| DVU-HP DVU-HP Integrated Reversible Heat Pump System The DVU-HP is a complete section with an integrated reversible heat pump for both heating and cooling, and a rotary heat exchanger for effective heat recovery. The section is delivered built into Systemair’s air handling units; Danvent DV and TIME ec, and is pretested from factory ready for operation.
DVU-HP | DVU-HP Example: TIME ec 25 with DVU-HP + DVU-HP advantages • F ully integrated DX reversible heat pump system for heating and cooling • I ntegrated rotary heat exchanger • S tepless control of capacity to ensure optimal indoor climate and minimal energy consumption • Very efficient, EER values up to 9,6 •C apacity suits all European climates and can provide cooling to a supply air temperature of +15 °C •E asy to calculate and full technical documentation • Configured and pretested from f
| DVU-HP 70 00 80 00 90 100 00 00 00 120 1600 0 DV 15 DV 20 DV 25 DV 30 DV 40 DV 50 DV 60 DV 80 5,3 0,8 1,2 1,6 2,0 2,5 3,0 4,0 4,8 1,00cooling capacity kW Total 27 41 55 65 79 102 137 165 Capacity from the cooling 70circuit kW 12 18 24 29 34 44 59 73 77 EER, total 7,2 7,1 6,7 6,9 7,1 7,6 8,0 7,5 8,2 Outdoor conditions: 34 °C/45% RH. Supply air: 16 °C. Extract air conditions: 23 °C/63% RH.
DVU-HP | DVU-HP Cooling and Heating Capacity, DV 40 with DVU-HP Heating capacity 130 kW 120 kW Cooling capacity 80 kW DVU-HP heating circuit DVU-HP cooling circuit Rotary heat exchanger Rotary heat exchanger 70 kW 110 kW 100 kW 60 kW 90 kW 50 kW 80 kW 70 kW 40 kW 60 kW 50 kW 30 kW 40 kW 20 kW 30 kW 20 kW 10 kW 10 kW -15 °C / 90% RH -10 °C / 85% RH - 5 °C / 80% RH 0 °C / 75% RH 5 °C / 70% RH Outdoor conditions 25 °C / 70% RH 28 °C / 60% RH 31 °C / 50% RH 34 °C / 45% RH 22 22 2
| DVU-HP DVU-HP Dimensions H W L DVU-HP size Width Height DVU-HP 10 for TIME ec and DV 970 970 Length 1420 DVU-HP 15 for TIME ec and DV 1120 1120 1420 DVU-HP 20 for TIME ec and DV 1270 1270 1420 DVU-HP 25 for TIME ec and DV 1420 1420 1420 DVU-HP 30 for TIME ec and DV 1570 1570 1570 DVU-HP 40 for TIME ec and DV 1720 1720 1570 DVU-HP 50 for DV 2020 2020 2320 DVU-HP 60 for DV 2170 2240 2460 2540 2460 DVU-HP 80 for DV * Rotary heat exchanger 2170/2320*
DVU-HP | SystemairCAD Design Programme documentation features all relevant consumption levels will be presented. SystemairCAD is the name of technical data and a specification text The most important preconditions are Systemair’s design programme for applicable for the tender documents. set as default, but can easily be adjumodular and compact air handling Everything that must be included in sted to any specific project. When the units. The programme is very userany professional project.