SAVE VSR 300/500 Installation instructions Document in original language | 254292 · v01 GB
© Copyright Systemair UAB All rights reserved E&OE Systemair UAB reserves the rights to alter their products without notice. This also applies to products already ordered, as long as it does not affect the previously agreed specifications. Systemair is not liable or bound by warranty if these instructions are not adhered to during installation or service.
Contents 1 2 3 4 5 6 7 8 9 Overview ......................................................1 1.1 General Description ................................1 1.2 Warranty ..............................................1 1.3 Type label.............................................1 Important Safety Information .............................1 2.1 Intended Use.........................................1 2.2 Admonitions .........................................2 Technical Data ......................................
Overview | 1 Overview 1.1 General Description Read the instructions carefully and in its entirety. For description of advanced settings and installation of accessories see Service and Accessories Installation manual. All documents can be found in our online catalogue at www.systemair.com. 1.2 Warranty For the assertion of warranty claims, the products must be correctly connected and operated, and used in accordance with the data sheets.
2 | Technical Data • The system should operate continuously, and only be stopped for maintenance/service. • Do not connect tumble dryers to the ventilation system. • Make sure that filters are mounted before starting the unit. 2.
Technical Data | 3.1 Dimensions and Weight 3.1.1 Dimensions and Weight of VSR 300 Fig. 2 Dimensions of VSR 300 * Drainage The unit weight is 65 kg. 3.1.2 Dimensions and Weight of VSR 500 Fig.
4 | Technical Data The unit weight is 77 kg. 3.2 Duct connections Fig. 4 Duct connections Symbol 3.3 3.3.1 Description Symbol Description Supply air Outdoor air Exhaust air Extract air Installation recommendation regarding condensation Condensation inside of the unit When the unit is installed in a cold attic (close to outdoor temperature) the unit should run continuously.
Delivery, Transport, Storage | Example B: If the unit is installed in room where temperature is 20°C, outside temperature is –25°C, then dew will start accumulating when relative humidity is 34% and higher. 4 Delivery, Transport, Storage 4.1 Transport and storage The SAVE VSR 300/500 should be stored and transported in such a way that it is protected against physical damage. It should be covered so dust, rain and snow cannot enter and damage the unit and its components.
6 | Installation B. Ceiling installation. Left and right connections are possible. A ceiling mounting kit is required. Not delivered with the unit. Needs to be ordered separately. C. Upside down installation is NOT allowed. 5.1 Location and Space Requirements The SAVE VSR 300/500 should preferably be installed in a separate room (e.g. storeroom, laundry room or similar.).
Installation | Fit the enclosed self adhesive vibration dampers on the unit. Make sure that the surface is flat and that it supports the weight of the unit. Perform the installation in accordance with local rules and regulations. 6.1 Condensation drainage In general no condensation drainage is needed for rotational heat exchangers at dry conditions. However, if a lot of humid air is present in the residence, a condensation drainage might be needed.
8 | Electrical connections 7 Electrical connections 7.1 Main circuit board layout The SAVE VSR 300/500 is equipped with built-in regulation and internal wiring. Fig.
Before Starting the System | Position Description 16 Terminals for speed control of extract air fan 17 Terminals for speed control of supply air fan 7.2 External connections (Connection board) External connections to the main circuit board are done via connection board situated inside of the unit. Fig.
10 | Commissioning • The unit is correctly wired 9 Commissioning Follow the first startup instructions and fill in the Commissioning record as you go through the settings. The Startup Wizard cannot be skipped. Note: If the SAVE LIGHT control panel is used, the start-up wizard is skipped and the factory settings are used. Select language, set the time and choose airflow control type. Select revolutions per minute as the type of airflow control only if these values are included with the device.
Disposal and recycling | 3. Make sure that the Commissioning record is complete. 4. Collect all tools. 5. Inform the appropriate person that work is finished. 6. Follow the procedures for the return and disposal of replacement parts and the disposal of packing. 11 Disposal and recycling This product is compliant with the European WEEE Directive and related national waste legislation. When disposing the unit, follow your local rules and regulations.
12 | EU Declaration of Conformity 12 EU Declaration of Conformity Manufacturer EN 60529 Systemair UAB Linų st. 101 LT–20174 Ukmergė, LITHUANIA Office: +370 340 60165 Fax: +370 340 60166 www.systemair.com The manufacturer hereby confirms that SAVE VSR 300/500 comply with all applicable requirements in the following directives and regulations.