Original instructions Thermowarm TWS SE .... 4 NL .... 54 GB .... 14 NO .... 24 DE .... 34 FR .... 44 FI ....64 ES .... 74 RU .... 84 PL ....
Thermowarm TWS TWS 333 / 453 / 753 242 / 362 / 662 47 150 208 123 Fig. 1 min 100 min 50 min 300 min 70 Fig.
Thermowarm TWS Thermowarm TWS100. (IP44) Type TWSE103 TWSE105 TWSE110 TWSD110 Output [W] 300 500 1000 1000 Voltage [V] 230V~ 230V~ 230V~ 400V~ Weight [kg] 1,7 2,2 3,2 3,2 Voltage [V] 230V~ 230V~ 400V~ Weight [kg] 2,2 3,2 3,2 Voltage [V] 230V~ 230V~ 230V~ Weight [kg] 1,7 2,2 3,2 Thermowarm TWS200. (IP44) Type TWSE205 TWSE210 TWSD210 Output [W] 500 1000 1000 Thermowarm TWSC.
GB Thermowarm TWS Installation and operating instructions General Instructions Read these instructions carefully before installation and use. Keep this manual for future reference. The product may only be used as set out in the assembly and operating instructions. The guarantee is only valid if the product is used in the manner intended and in accordance with the instructions.
Thermowarm TWS GB Handling of product at end of working life This product may contain substances necessary for functionality of product but potentially dangerous for the environment. The product should not be disposed mixed with general household waste but delivered to a designated collection point for environmental recycling. Please contact local authority for further details of your nearest designated collection point.
Thermowarm TWS GB Control This product is considered a local space heater according to Ecodesign Regulation (EU) 2015/1188 and is equipped with smart control which among others includes : • Electronic room temperature control plus week timer • Room temperature control with open window detection • Adaptive start control The TWS convector has a digital display where all settings are made. The protective display cover is available as an option.
Thermowarm TWS GB Display symbols User menu Surrounding active frame Open window mode on Function in AUTO mode override. Flashing: ITCS function Programme number Settings menu -1 -2 Current day Heat on -1 -2 Display lock on Current room temperature (actual value) 12H AM/PM or 24H Timeline for the current week program.
Thermowarm TWS GB Operating modes It is possible to choose between four modes – comfort, reduced mode (night mode), automatic mode or frost protection. Settings for Comfort mode and Reduced mode are also applied in the week program when used. Default settings Temperature mode Set point Range Comfort mode 21 °C 5 - 30 °C Reduced (night mode) 18 °C 5 - 30 °C Frost protection See the Settings menu.
Thermowarm TWS GB Timer The set point value can be changed for a limited period using the timer (15 minutes to 44 days). User menu Select OK Confirm Set the desired time. 15 minutes - 44 days (’ minute, h hour, d day) OK Confirm Set the desired room temperature. OK Confirm While the timer is running, its symbol flashes and the display alternately shows the remaining time and the set temperature. When time is up the unit returns to previous settings.
Thermowarm TWS GB Week program There are nine preset weekly programmes (P1-P9) and the potential to add an additional four (U1-U4). The function ITCS (default) makes the control learn when it needs to start in order to reach a certain desired temperature at a specific time in the environment it is used. This function can be deactivated (see Settings menu).
Thermowarm TWS Setting week programs User menu Select GB Following days, Tue - Sun It is now possible to copy the previous day (COPY). P Select YES to copy the previous day’s settings or select NO. P1 or the recently used program is shown. OK Confirm Selecting a preset program P1 - P9 Select P1-P9. Switch between days of the week with the arrow to view times for the selected program. 1 = Mon to 7 = Sun.
Thermowarm TWS GB Settings menu OK Calibration of temperature sensor This is done in the Settings menu. Press and hold for 5 seconds. OK Press and hold for 5 seconds. Browse to Calibration of temperature sensor (5). OK Confirm Home screen Browse between the menu options. OK Confirm See the table on the next page regarding settings that can be made. The first screen displays the measured temperature. Press “OK” to view the offset value.
Thermowarm TWS Menu options GB Functions Default settings Description ProG (01) If "no" is selected, a simplified user menu appears where it is only possible to select between two operating modes: comfort mode and reduced mode. YES (activated function) Switch between YES and no using +/-. Confirm with OK. dEG (02) Change temperature unit. °C Switch between °C and °F using +/-. Confirm with OK. 24H (03) For week program. Set the time format.
Tel: +46 31 336 86 00 mailbox@frico.se www.frico.net For latest updated information and information about your local contact: www.frico.net. Art.