Air Distribution Products CFC Clean Filtering Cassettes Data Sheet
/ 28 | Clean Filter Cassettes Table of Contents Description . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Quick Selection . . . . . . . . . . . . . . . . . . . . . . . . 7 Product Types . . . . . . . . . . . . . . . . . . . . . . . . . 9 CFC-C . . . . . . . . . . . . . . . . . . . . . . . . . . .
Clean Filter Cassettes Description The clean filtering cassettes for clean areas are intended for filtering the air supplied into areas with high requirements for hygiene and particle-free environment, such as operating rooms, intensive care units, laboratories, clean manufacturing areas etc. It is possible to install filters that have a filtration class in EPA, HEPA and ULPA range with rubber gaskets or gel gaskets into the filtering cassettes for the highest possible tightness.
/ 28 | Clean Filter Cassettes Design Material Composition All the clean filtering cassette types are manufactured from a carbon steel sheet with a powder coating surface finish, signal white RAL9003 gloss 30% as standard. Other RAL colours available upon request. The structural joints on the clean filtering cassette casings are consistently welded to ensure the cassette airtightness in front of as well as behind the filter.
| 5 / 28 Clean Filter Cassettes Tab.
/ 28 | Clean Filter Cassettes Types of CFC Installation • The ceiling clean filtering cassettes are mounted by suspension into a supporting ceiling. For this purpose they are equipped with hangers. The details of embedding for the respective types of suspended ceilings are demonstrated on Fig. 2 up to Fig. 4 (below). • Clean filtering cassettes with the type 1 front panel fitting surface are by default intended for installation into a plasterboard suspended ceiling (see Fig. 2 below).
Clean Filter Cassettes | 7 / 28 Tab.
Clean Filter Cassettes Legend pS (Pa) Pressure drop qv (m /h) (l/s) Air flow volume vF (m/s) Filter face velocity 3 CFC - without front diffuser panel 175 pS (Pa) 150 Relation between filter face velocity and pressure drop on clean filtering cassettes without front diffuser panel, equipped by 80 mm thick H14 filter.
Clean Filter Cassettes | 9 / 28 Product Types CFC-C CFC-C Design Classic Clean Filtering Cassette Whole box is hermetically welded.
Clean Filter Cassettes Tab.
Clean Filter Cassettes | 11 / 28 Ordering Code 1 Simple (Type 2) 2 Side H Connection Top V Nominal Dimensions 2) Length × Width × Thickness A×B×T Signal white RAL9003, 30% gloss SW Other RAL colour RALXXXX Front Panel Fitting Surface 1) Surface Finish 3) - - - NOTES: 1) See Fig. 1. 2) See Tab. 3 Nominal dimensions A × B are identical with dimensions of corresponding filter. Thickness 80 mm as standard. If filter thickness 80 is denoted, the cassette can be used with filters 69 mm .
Clean Filter Cassettes CFC-B Design Basic Clean Filtering Cassette “Dirty side” (in front of the filter - in the sense of air flow) of the box is spot welded. “Clean side” (behind the filter - in the sense of air flow) is hermetically welded.
Clean Filter Cassettes | 13 / 28 Tab.
CFC-B 14 / 28 | Clean Filter Cassettes Ordering Code CFC-BWith alignment rim (Type 1) 1 Front Panel Fitting Surface 1) Simple (Type 2) 2 Nominal Dimensions Length × Width × Thickness A×B×T 2) - - - 100 200 250 Connection Nominal Size Surface Finish 4) 3) DN (mm) 315 Signal white RAL9003, 30% gloss SW Other RAL colour RALXXXX NOTES: 1) See Fig. 1. 2) See Tab. 4 Nominal dimensions A × B are identical with dimensions of corresponding filter. Thickness 80 mm as standard.
Clean Filter Cassettes | 15 / 28 CFC-G Design Whole box is hermetically welded. • Connection: Air tight, side or top circular connection • Filter Gasket: Gel filter gaskets with blade sealing surface (absolute tight) • Front Diffuser Panel Mounting: Mounting method 1B (one central bolt into the central fixing traverse) • Type of Installation: Plasterboard suspended ceiling Description Technical Parameters are available at design.systemair.
Clean Filter Cassettes Tab. 5: Dimensions of the CFC-G A1 (mm) B1 (mm) øD/DN (mm) Connection (mm) 496 584 158/160 Hside 649 198/200 248/250 465 563 425 Htop 610 × 610 × 128 344 610 × 610 × 80 545 × 545 × 80 Nominal Dimensions 1) A × B × T (mm) 457 × 457 × 80 Front Panel Fitting Surface: Type 1 305 × 305 × 80 CFC-G 16 / 28 | 313 361 Plasterboard Suspended Ceiling NOTE: 1) The nominal dimensions of CFC are related to exact dimensions of corresponding flters.
Clean Filter Cassettes | 17 / 28 CFC-R Design Whole box is hermetically welded.
Clean Filter Cassettes 648 C (mm) 382 534 612 634 652 687 Connection Lh (mm) 200 350 450 610 × 610 × 80 613 575 × 575 × 80 595 557 × 557 × 80 573 623 620 638 457 × 457 × 80 495 588 305 × 305 × 80 343 B1 (mm) 570 470 C (mm) 368 520 598 Connection Lh (mm) 200 350 A1 (mm) B1 (mm) A1 (mm) 548 318 Nominal Dimensions 1) A × B × T (mm) 610 × 610 × 80 575 × 575 × 80 557 × 557 × 80 535 × 535 × 80 Nominal Dimensions 1) A × B × T (mm) 457 × 457 × 80 Front Panel Fitting S
Clean Filter Cassettes | 19 / 28 CFC-W Whole box is hermetically welded. • Connection: Air tight, side circular connection • Filter Gasket: Double row rubber filter gaskets with flat sealing surface • Ventilation Grille Mounting: Slide-in fixing • Type of Installation: Wall installation Description CFC-W is a high standard clean filtering cassette for EPA, HEPA or ULPA type filters. It is intended mainly for filtering of supply air. Suitable ventilation grille: CFC-NB (see Tab. 2).
Clean Filter Cassettes Accessories CFC-PP, CFC-SF, CFC-AQ, CFC-VR, CFC-VN and CFC-NA Front Diffuser Panels and Ventilation Grille Description Recommended equipment for CFC are the front diffuser panels or the ventilation grilles. Design From the design and parameter point of view the front diffuser panels and ventilation grilles are identical to the standard Systemair diffusers and grilles. The only difference is in the outer dimensions.
Clean Filter Cassettes | 21 / 28 Ordering Code CFC- - - SF AQ VR VN Front Diffuser Panel or Ventilation Grille Type Corresponding Filter Dimensions NA A×B 2) Surface Finish 4) Signal white RAL9003, 30% gloss SW Other RAL colour RALXXXX NOTES: 1) If no Surface finish is defined, RAL9003 will be delivered. Example of the Ordering Code CFC-SF-305×305-SW Front diffuser panel CFC-SF for filter dimensions 305 × 305 mm. Signal white powder coating.
ACCESSORIES 22 / 28 | Clean Filter Cassettes Tab.
Clean Filter Cassettes | 23 / 28 CFC-AF Dimensions Adapter Ledge Description B1 When mounting the clean filtering cassette into a metal plate or a T-bar suspended ceiling, the clean filtering cassette is equipped with adapter ledges to adjust the given clean filtering cassette dimensions to the installation opening size (see Fig. 3 and Fig. 4). It is needed to specify the corresponding information in the ordering code (in the „Ceiling type, raster“ field).
Clean Filter Cassettes CFC-GF & CFC-HF Dimensions Filters Dimensions of the filters (A × B × T) are identical with the clean filtering cassettes nominal dimensions (see Tab. 3 up to Tab. 7). Description B ACCESSORIES 24 / 28 | EPA, HEPA and ULPA filters with class E11 up to U16 are intended for the clean filtering cassettes. Recommended standard equipment for CFC is the class H14 filter. The filter thickness is 80 or 150 mm. A T Fig.
Clean Filter Cassettes Installation, Maintenance & Operation Information about installation, maintenance and operation is available in the “InstalMaintenOperInstr_PP-38_ CFC_201702” document on Systemair DESIGN. Dry indoor conditions with an operation temperature range of -20°C to +50°C. Transport & Storage Dry indoor conditions with a temperature range of -20°C to +40°C. Supplement Any deviations from the technical specifications contained herein and the terms should be discussed with the manufacturer.
/ 28 | Clean Filter Cassettes
Clean Filter Cassettes | 27 / 28
www.systemair.com Systemair Production a.s.