Original instructions Thermoplus SE .... 7 GB .... 17 NO .... 27 FR .... 37 DE .... 47 FI .... 57 NL .... 67 PL .... 77 RU ....
Thermoplus Thermoplus EC Thermoplus ECV/ECVTN ø22 (2x) Type A [mm] B [mm] Type A [mm] B [mm] EC450 1076 600 ECV/ECVTN300 870 400 EC600 1505 900 ECV/ECVTN550 1505 900 EC750 1810 1200 ECV/ECVTN700 1810 1200 EC900 2140 1800 Mounting on the wall 135 Mounting on the ceiling Ceiling fixture TF1 2
Thermoplus Minimum mounting distance A B C D E [mm] 60 25 90 25 1800 Flammable material Flammable material, e.
Thermoplus 4 1 5 2 6 3 7 4 8
Thermoplus Technical specifications Thermoplus EC (IP20) Type Output (1) [W] EC45021 EC60021 EC75021 EC90021 EC90031 450 600 750 900 900 Voltage (2) [V] 230V~ 230V~ 230V~ 230V~ 400V2~ Amperage (3) Max. surface temp. (4) [A] [°C] 2,0 180 2,6 180 3,3 180 3,9 180 2,3 180 Weight (6) Amperage (3) Max. surface temp. (4) [A] [°C] 1,3 180 2,4 180 1,4 180 3,0 180 1,8 180 Weight (6) Amperage (3) Max. surface temp.
Thermoplus Wiring diagram Control by thermostat 230V~ 230V~ L1 L2 L3 N °C A1A2 L1 L2 EC/ECV 230V~ L1 T1 L2 T2 L3 T3 N N RB3 Control by built-in thermostat 230 V ~ L N (ECV) 1 2 LOAD TAP16R LOAD 6 SENSOR SENSOR ECVTN SENSOR L N SENSOR TAP16R LOAD SENSOR SENSOR LOAD LOAD L N °C TAP16R LOAD °C N L C L1 L2 L3 N EC/ECV 400V2~ °C
Thermoplus EN Installation and operating instructions 3. Break off the top spacing part of the General Instructions Read these instructions carefully before installation and use. Keep this manual for future reference. The product may only be used as set out in the assembly and operating instructions. The guarantee is only valid if the product is used in the manner intended and in accordance with the instructions.
EN Thermoplus Residual current circuit breaker When the installation is protected by means of a residual current circuit breaker, which trips when the appliance is connected, this may be due to moisture in the heating element. When an appliance containing a heater element has not been used for a long period or stored in a damp environment, moisture can enter the element.
EN Thermoplus Control ECVTN Thermoplus ECVTN has an integrated thermostat with digital display on which all settings are made. Symbols on the display 6 7 1 2 3 8 4 9 5 1. Day of the week 2. Time and date 3. Selected menu/Current temp (actual value) °C 4. Set temp (set point) °C 5. Control (F) = sensor selection ECVTN 6. Shows that a program is running 7. Lock symbol 8. Program 9.
EN Thermoplus Start up Using the menu This is what the display looks like at first start. LED Start the menu Time Navigate through the options Exit the menu* Day Temp Control (F) Arrow buttons ] [ Select button [ ] Turning off and on To standby* 4 secs Locking the keypad Out of standby 4 secs *The heat is not being regulated. The clock is running and the programming is saved in the memory. 20 *Or wait 30 secs and exit automatically.
EN Thermoplus Basic settings Time and date To be able to use all the functions you need to set the time and date first. Navigate to the correct time* *Repeat the last two steps to set minutes, day, month and year. The correct day of the week is set automatically. Desired temperature Show actual temperature Lock buttons first The measured temperature is displayed.
EN Thermoplus Other settings Time and date Light and contrast Set time format Set the light intensity of the LED Press Press and navigate to SET. and navigate to SET. Select with Select with Navigate to DISP and select with Navigate to LED and select with Navigate between 12- and 24-hour format. Confirm with Turn off DST The calendar switches to DST automatically. This function can be turned off. Navigate between LED L (weak light) and LED H (strong light).
Thermoplus Adaptive function The thermostat has a function which works out when the heating should start to give the correct temperature at the correct time. It is activated on delivery, but can be turned off: Press and navigate to SET. Select with Navigate to AF, Select with Navigate between ON/OFF. Confirm with EN operation time as a percentage for the last 7/30/365 days. LED The LED allows you to see the current status of the thermostat. Green light – the thermostat is on and the heat is turned off.
EN Thermoplus Energy saving programs Save energy cleverly and easily! With these programs the heating is adapted to your actual needs and the heat is turned down when it isn’t needed.
Thermoplus Frost protection program Press This program is ideal for when you want to protect against frost damage in premises which are standing empty or unused for long periods, such as holiday homes and warehouses, or when you will be away from your main home for longer than usual. You set a desired value (set point) and the thermostat regulates the temperature in line with this. The normal settings remain in the memory and the thermostat reverts to them when the frost protection program is deactivated.
EN Thermoplus Sitemap of the menu This is how the menu in the thermostat is structured. Here you can quickly see where all the functions and settings are. CONT Set the display’s contrast PROG Start/stop program 1-8 UTIL Show connected time in % Home program 24 HR Office program 7D Personal program 30 D Frost protection program 365 D SET Various settings CLK Set time and date. S Turn off and set to automatic change to DST.
Tel: +46 31 336 86 00 mailbox@frico.se www.frico.net For latest updated information and information about your local contact: www.frico.net.