Wireless Damper Controller Installation and User Manual Document Number Author Revision Date 85-0883-001 Lisa Brown 1.
SynapSense Installation and User Manual Table of Contents Regulatory Notices............................................................................................................ 3 1 Operation .................................................................................................................... 5 2 Wireless Damper Controller Installation Requirements....................................... 6 2.1 2.2 3 Mounting ........................................................................
SynapSense Installation and User Manual Regulatory Notices Notice to Users: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
SynapSense Installation and User Manual Warranty Information Limited One Year Warranty Our company warrants that for two years from the date of purchase, it will replace this product if found to be defective in materials or workmanship. For a prompt, no charge replacement of equivalent product, return the defective product postage prepaid to the appropriate address.
SynapSense Installation and User Manual 1 Operation A SynapSense Node, such as the Wireless Damper Controller, is designed to work in conjunction with a SynapSense Gateway device and the SynapSoft console. Please be sure you have correctly configured SynapSoft on the gateway computer prior to continuing. Nodes can be added to an existing SynapSense Wireless Sensor Network (driven by a Gateway) or be used to form a network.
SynapSense Installation and User Manual 2 Wireless Damper Controller Installation Requirements 2.1 Mounting The Wireless Damper Controller mounts to any flat surface via mounting screws ranging from #6 to ¼”. See Outline Drawing for mounting bolt pattern.
SynapSense Installation and User Manual 2.2 Connections Unscrew and remove the clear lid from the device. The connections noted below should be drawn through the available conduit connectors as shown in the outline drawings in section 2.1. Power Input AC or DC input power should be connected to the two-terminal block as labeled on the product. Parameter AC Input DC Input Min 20.4 20.4 Typical 24 24 Max 27.6 27.
SynapSense Installation and User Manual 3 Troubleshooting and Diagnostics No light indication Power loss. Solid red light Actuator Control error condition. The actuator has not responded to the control system, check the electrical connections. Blinking red light The Wireless Sensor Network link is not established and is in progress. Failure to establish connection with the network may indicate a network configuration error or weak signal conditions.