SYMEO LOCAL POSITIONING RADAR Product: LPR®-1D24 (Symeo BSV101757) Product Documentation Table of Content Copyright © SYMEO GmbH 2009 Date: August 2009 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting Content 1 GENERAL INFORMATION ........................................................................................ 6 1.1 Safety Instructions .................................................................................................... 6 1.2 Mounting.................................................................................................................... 6 1.3 Repairs.........................
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting 6 LPR®-1D24 HOUSING DIMENSIONS ...................................................................... 17 7 WEB USER INTERFACE FOR LPR®-1D24.............................................................. 18 7.1 Requirements .......................................................................................................... 18 7.1.1 Connection to LPR®-1D24 Unit ...................................................
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting Table of Figures Figure 1: LPR®-1D24 measurement path .............................................................................. 8 Figure 2: LPR®-1D24 unit inclusive mounting bracket...........................................................10 Figure 3: Mounting of the fall protection ................................................................................11 Figure 4: LPR®-1D24 Connectors ..................
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting The documentation for the LPR®-1D24 Local Positioning Radar System is published by: SYMEO GmbH Prof.-Messerschmitt-Str. 3 D-85579 Neubiberg www.symeo.de If you have any questions or suggestions, please contact: Email: info@symeo.com phone: +49 89 660 7796 0 Copyright Symeo GmbH 2010 All rights reserved HISTORY Version Date Description 1.00 29.01.
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting 1 General Information 1.1 Safety Instructions LPR®-1D24 Systems are purely tracking and assistance systems. They therefore do not satisfy special requirements for personal safety. Follow the safety instructions in this documentation! 1.2 Mounting All mounting, installation and maintenance work must be carried out by an electrically qualified or trained person! 1.
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting 1.6 Setup and Operation During mounting, make sure that no objects or liquids reach inside the device (risk of short-circuit). In case of emergency (e.g. damaged housing, control elements or power cables, penetration of liquids or foreign bodies) switch off the device immediately, disconnect from the power line the device and inform your SYMEO service.
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting 2 Overview of LPR®-1D24 Unit LPR®-1D24 is a highly precise radio sensor for distance measurement. Two paired units allow for long range applications and enable additional data transfer at the same time. The exact position of a moving machine component, e.g. a crane or crane trolley, can thus be dynamically determined in real-time, while data collected at one end (e.g.
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting 2.1 Technical Data LPR®-1D24 Unit The technical specifications for LPR®-1D24 can be found in our data-sheet under the following link: http://www.symeo.com/cms/upload/pdf/en/DataSheets/Symeo_Datasheet_LPR-1D24.pdf Overview of LPR®-1D24 Unit Copyright © SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting 3 Mounting and Alignment of LPR®-1D24 Units The device must be secured against falling. All mounting, installation and maintenance work must be carried out by electrician or a person with similar training and skills! The LPR®-1D24 units are delivered with a separate mounting bracket (see Figure 2). Figure 2 shows a complete system including the mounting bracket.
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting 3.1 Mounting of the Fall Protection The LPR®-1D24 units must be protected against fall. For every unit Symeo provides a protection set consisting of the following components: A: 2 x ring nuts M5, B: 2 x snap hooks 5 x 50 mm C: 1 x steel cable 3 mm x 1 m The two ring nuts must be mounted on the back of the LPR®-1D24 unit laterally on the respective second screw from above, which are 4 mm longer than the other screws.
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting 4 Requirements for Power Supply The power supply should have the following characteristics: Potential free Output power at least 25 W Output voltage 10 V DC to 36 V DC Short-term maximum current flow (when switched on): o At 24 V DC: 2000 mA for 50 ms o At 12 V DC: 2500 mA for 50 ms Requirements for Power Supply Copyright © SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting 5 Specification of the Connectors 5.1 Overview of Connections All connectors are fixed externally to the housing. Figure 4 shows the connections in detail.
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting 5.2 Power Supply The LPR®-1D24 unit is powered by a 4-pin M12-Connector to the operating voltage (Figure 4 – Connection B6). 5.2.1 Plugs Recommended connector: o SACC-M12FST-4PECON-PG 9-M – 1418052 Cable diameter: 6 - 8 mm Symeo order number: MTE101761 Figure 5: M12 Connector for the power requirement 5.2.
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting 5.3.1 Plugs Recommended connector: Connector Ethernet M12 o SACC-M12MSD-4CON-PG 7-SH – 1521258 Cable diameter: 4 – 6 mm (PG7) Symeo order number: MTE101768 Figure 6: M12 Ethernet M12 5.3.
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting 5.4.1 Plugs Recommended connector: Connector: SCPU-10-G-02.00-MBS-AM from Samtec USB mini-B-plug Pin assignment according to USB-Standard If the USB-port at the device is not used, it must be closed with the end cap to prevent leakage. 5.5 USB – A Devices The LPR®-1D24 unit has a USB-Flash Drive Connector, on which the data can be logged for service purposes (Figure 4 – Connection B8).
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting 6 LPR®-1D24 Housing Dimensions ® Figure 7: LPR -1D24 Housing Dimensions The minimum pipe diameter is 40 mm, the maximum pipe diameter is 75 mm. LPR®-1D24 Housing Dimensions Copyright © SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting 7 Web User Interface for LPR®-1D24 This chapter describes the LPR®-1D24 Web User Interface. Connection via the Ethernet is required! For the Ethernet-connection the connector cable M12 – RJ45 is required for configuration of the LPR® -1D24 units with M12 plug and RJ 45 connector. This connector cable can be ordered by Symeo (see 5.3.3). 7.
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting Enter the following fixed IP-address i.e. 192.168.1.1. The subnet mask should be set to 255.255.255.0. Click in both windows OK. Figure 8: Network Settings If the firewall settings are too restrictive, you may not get access to the LPR®-1D24 unit. In this case deactivate the firewall temporarily. The LPR® unit should be available via your PC now.
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting 7.2 Open User Interface At delivery, the IP-address of the LPR®-1D24 unit is 192.168.1.99, unless another IP-address is labeled outside the box. Open your web browser. In the address bar of the web browser enter the IP-address of the LPR®-1D24 unit: http://192.168.1.99. Press Enter. A connection is established with your LPR®-1D24 unit.
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting Enter the user name "symeo" and the password "54all2u" and press "Login". Now your status is displayed as "Logged in". ® Figure 11: Sign in on the home page of the LPR -1D24 unit You can always come back to this page if you press on the Symeo symbol or the Symeo character in the top left hand corner of this page. Web User Interface for LPR®-1D24 Copyright © SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting 7.
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting 7.4 Device - Device Configuration With this function (see picture below) you can chose either to: define the LAN settings define Modem settings define the Profibus settings define the Remote Access settings set the System Time set WLAN settings Figure 14 – Device: Device Configuration Menu Web User Interface for LPR®-1D24 Copyright © SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting 7.4.
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting Following message appears in the upper left corner “Saved successfully” (see picture below). Furthermore it will be shown in green, what has been saved (in the picture below the hostname). Now you need to press “Commit” if you want to apply the change. The unit will perform a reboot to apply it. If you want to discard the change, press “Reset”.
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting 7.4.2 Device - Device Configuration – System Time With this function (see picture below) you chose to set the time zone o must be set to custom timezone if needed timezone is not in the dropdown menu set the IP-address of the NTP-server set the Custom timezone o needs to be filled if custom timezone is used Figure 18 – Device: Device Configuration - SystemTime Settings 7.
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting Figure 19 – Device: Application Settings 7.5.1 Device - Application Settings – Customer Protocol With this function (see picture below) you chose to: set the Protocol frame length set the Protocol TCP port define the Output interval of customer protocol Figure 20 – Device: Application Settings - Costumer Protocol Settings 7.5.
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting Measurement mode o Measuring mode for the LPR®-1D24 unit. Any measuring pair of LPR®-1D24 units has to consist of one Master and one Slave Unit. FSK communication channel o Data communication channel number. Has to be the same on all units needing to communicate with each other.
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting Figure 22: Example configuration of one measurement pair Master and Slave Unit Configuration rules: Don’t use a group ID more than once per site. If pairs of LPR®-units are mounted close to each other, the FSK channels should be at least two channels apart from each other. The bandwidth variation number should stay on the default value 0.
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting 7.6 Diagnostics With this function (see picture below) you chose to: Operating System Status Hardware Status Record measurement data Distance over time diagram Signal strength over distance diagram Figure 23 – Diagnostics Menu Web User Interface for LPR®-1D24 Copyright © SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting 7.6.1 Diagnostics - Operating System Status With this function (see picture below) the operating system status can be seen. In case of problems, these information may be asked by Symeo support. Figure 24 – Diagnostics: Operating System Status Web User Interface for LPR®-1D24 Copyright © SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting 7.6.2 Diagnostics - Hardware Status With this function (see picture below) system values and system voltages are displayed. In case of problems, these information may be asked by Symeo support. Figure 25 – Diagnostics: Hardware Status This display is automatically refreshed every 5 seconds. Web User Interface for LPR®-1D24 Copyright © SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting 7.6.3 Diagnostics - Distance over Time With this function (see picture below) the current distance and the current RSSI value (Signal strength) will be displayed. Furthermore the distance over time graph. Figure 26 – Diagnostics: Distance over time By pointing the mouse in the graph and using the scroll wheel you can downsize or enlarge the timeline.
SYMEO Local Positioning Radar System LPR®-1D24 LPR®-1D24 Station – Overview and Mounting 7.6.4 Diagnostics - Signal Strength over Distance Diagram Figure 27 – Diagnostics: Signal strength over distance diagram This diagram shows the recorded distance-signal strength pairs since the last power-on. You can use it to detect abnormal signal propagation routes at certain constellations of the two LPR®-1D24 stations, as the signal strength should decrease with increasing distance.