SYMEO LOCAL POSITIONING RADAR Product: LPR®-1DXi Product Documentation
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation Content 1 OVERVIEW ................................................................................................................ 5 1.1 Safety Instructions .................................................................................................... 5 1.2 Installation ................................................................................................................. 6 1.3 Repairs.............................
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation 4.4 Relay Connection .................................................................................................... 15 4.5 Mounting.................................................................................................................. 16 4.6 Installation Notes for Antennas ............................................................................. 17 4.6.1 Fresnel Zone ...............................................
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation The documentation for the LPR®-1DXi Local Positioning Radar System is published by: SYMEO GmbH Prof.-Messerschmitt-Str. 3 D-85579 Neubiberg www.symeo.de If you have any questions or suggestions, please contact: Email: info@symeo.com Phone: +49 89 660 7796 0 Copyright Symeo GmbH 2014 All Rights Reserved HISTORY Version Date Description 1.02 17.06.2010 USB driver installation changed 1.03 06.08.2010 Added notes for FCC/IC 1.
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation 1 Overview SYMEO Industrial Local Positioning Radar (LPR®) is a system for contactless, real-time determination of distances between two devices by means of radio signals. All components are integrated in one casing. The compact unit can therefore be mounted very easily and operate maintenance-free, even under harsh conditions. Dust, fog, or similar impacts do not influence the system.
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation 1.2 Installation All installation, repair and servicing work must be carried out by qualified and trained technicians! 1.3 Repairs Repairs to the device must be carried out by authorized technicians. Unauthorized opening and incorrect repairs could result in severe danger to the user (danger of electric shock, radiated energy, fire hazard). 1.
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation Protect the contacts of all of the device's sockets and plugs from static electricity. Do not touch the contacts. If it is ever necessary to touch the contacts, take the following precautionary measures: Touch a grounded object or carry a ground strap before touching the contacts. This will divert static charges.
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation 2 System Description 2.1 Mode of Operation The distance is determined by measuring the transit time of radio signals. One unit initiates the measurement and the second unit replies. With the software Symeo-Wizard (via Windows PC) the distances for adjustable switching points are determined and transferred to the LPR®-1DXi device. Upon reaching a switching threshold, on-board relays open dry contacts.
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation 2.3 System Configuration The LPR®-1DXi system consists of two LPR®-1DXi units. For distance measurement and collision-avoidance, the two units are arranged as shown in Figure 2. The distance readings and relays are available at both of the paired units. ® Figure 2: LPR -1DXi system 2.4 System Design Each LPR® 1DXi unit has parameters to provide an explicit allocation to a system and also to ensure the functionality of a system.
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation 2.4.3 Frequency Channel The measurement takes place in a frequency band width of 5,725 to 5,875 GHz. In this band width a frequency channel is assigned to the LPR®-1DXi system. 30 different frequency channels are available. Two units in one LPR®-1DXi system need the same frequency channel. If there are more LPR®-1DXi systems in your environment each further LPR®-1DXi system needs different frequency channels.
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation 3 Hardware All corresponding installation, repair and servicing work must be carried out by qualified and trained technicians. 3.1 Component Setup of the LPR®-1DXi Unit The LPR®-1DXi unit consists of mounting bracket A, casing with electronic devices B and antenna C as shown in Figure 3.
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation The antenna C has to be mounted in correct polarization (C2) as shown in Figure 3 3.2 Cable Glands, Interfaces and LED Display of the LPR®-1DXi Unit The casing B has two cable glands for power cable (B6) and cable for the connection to the on-board relays (B5). Additionally the pressure equalization membrane (B7) is shown.
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation On the side of the casing the USB port (B4) for parameter setting with the software SymeoWizard and two two-colored LED (B8, B9) are located, displaying different statuses of the device.
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation 4 Installation 4.1 Important Instructions for Installation Avoid entry of foreign objects or liquids into the system unit, especially on the PCB stack in casing B. The seal (B10) seals front and rear element when it is mounted correctly. Otherwise the housing will not be sealed in a water-proof manner.
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation 4.3 RS 232 Connection For optional distance reading RS 232 is connected using the RS232 terminal block B3. Figure 8 shows the pin assignment. Please use the same cable as for the power supply with additional three wires. Figure 8: RS232 terminal block B3 4.4 Relay Connection Relays are connected using the relay terminal block B1. Figure 9 shows the pin assignment for the seven switch relays with dry contacts.
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation 4.5 Mounting All installation, repair and servicing work must be carried out by qualified and trained technicians! When the system is mounted on fixed tubes the necessary measures to prevent slippage of the system must be taken ® Figure 10: LPR -1DXi unit rear view The LPR®-1DXi unit is delivered pre-mounted (casing B and antenna C), and with a separate mounting bracket A.
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation Mount the mounting bracket A on a pole or wall at a suitable place. Do not tighten the screws of the adjustment yet, the system must be aligned first. Mount the LPR®-1DXi casing on the mounting bracket A with 4 hex nuts A4 using flat wrench SW8. Carefully align both units (refer to chapter 4.6). When the system is powered, the red LED B9 of the display element is turned on.
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation 4.6.2 Alignment of LPR®-1DXi Units The LPR®-1DXi units with the integrated antennas have to be mounted without any offset (no difference in height and no offset sideways). Make sure that the opening angle is symmetric to the relative direction of motion (compare picture 1 vs. picture 2 in Figure 12). If an offset is not inevitable the units have to be tilted (compare picture 3 vs. picture 4 in Figure 12).
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation Configuration software Symeo-Wizard and USB-driver are installed on your Windows PC, both on product documentation CD delivered with your LPR®-1DXi devices. Data link to your PC has been established over USB (jack B4) Once these prerequisites have been fulfilled, you can set parameters with the software Symeo-Wizard for each station. 5.2 Commissioning Tool – LPR®-1DXi Wizard 5.2.
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation After finishing the installation process the LPR®-1D Wizard starts automatically. A Shortcut was created on your desktop and you can find the Symeo LPR®-1D Wizard in your start menu. 5.2.
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation New project To start a new configuration push ‚New project‘. Select the product family of the system LPR-1DXi. Figure 18 – New project / Select product family Open existing project If you already saved a project file you can open this project file for further settings. Push ‚Open existing project ‘ Select your already created project file and push ‚Open‘ Figure 19 – Open existing project Select application Push ‚Edit project‘.
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation application settings can be selected. Settings of LPR® System Parameters After selecting the application common settings of the LPR® system has to be entered. The ‚Common settings‘ include settings for the complete LPR® System. Fill in the input fields on the right side of the window. The fields depend on the selected application. Move the cursor above an input field to see more information about it.
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation measurement cycle of 35 ms. Push ‚Next step‘. The ‚Group Master settings‘ are displayed. Fill in the input fields of the ‚Group Master settings’. Interface: Cannot be changed. Data Port rate: Transmission rate of the LPR® system on the RS232 data port. If you change the baud rate to 9600 you should also adjust the measurement cycle of the system to values >50ms. Antenna port 1 and Antenna port 2: Cannot be changed.
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation Fill in the input fields of the ‚Slave 1 settings’ as already described in the ‚Group Master settings’.
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation Setting the X and Y dimensions for warning and stop areas For LPR® 1DXi units you can set the distances for warning and stop areas for relay switching in this menu . Fill in the values of the warning and stop distances for your application in meters. System failure timeout: Length of time without valid measurements before a system failure is indicated. Relay reenabling time: Use this value to setup hysteresis.
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation Usage of Relays You can allocate functionalities to each of the seven relays in the LPR® 1DXi unit. Each LPR® 1DXi unit in one system can have a different assignment of relays. You can choose between default settings, customer settings and no relay assignment. The possible functionalities of the relays depend on the application you have selected.
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation Connection to LPR®-1DXi unit Having established a connection to the LPR®-1DXi unit via USB with your PC the connection can be opened by pushing the ,Connection’ button, followed by pushing ,Connect via RS232/USB’. The USB-driver from the product CD(or USB-Stick) has to be installed first... ® Figure 27 – Connection to LPR unit Connect via RS232/USB: To open the serial connection, select the right COM port of your computer.
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation Unit configuration: Push ,Unit configuration’. Select an entry from the ,Configure connected unit as’ pull-down list. Push ,Upload Config’ Figure 30 – Unit configuration If a new application is selected or settings are changed, you have to make an upload for each LPR® unit of one system. Display of Distance Data Click the button ‚Distance Data‘.
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation Antenna Calibration After uploading all configuration files to each LPR® unit, you have to calibrate the measured distance. Push ‚Antenna calibration‘. In the field ‚Measured Distance‘ the measured distance is displayed in meters, which is different to the real distance. Figure 32 – Antenna calibration Enter the real distance value between the two antennas in the field ‚Real distance‘. Push ‚Calibrate‘.
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation Enter the desired file name for the raw configuration file and save the file. The format of this raw configuration file is “customers defined file name.bas” The download of raw configuration files is only required for service issues. Please contact Symeo service for further instructions. Figure 34 –Enter file name Upload Configuration Pressing the button ‚Upload‘ a raw configuration file can be uploaded to each LPR® unit.
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation Press the ‚Open‘-button. The selected raw configuration file will be uploaded to the connected LPR® unit. The upload of raw configuration files is only required for service issues. Please contact Symeo service for further instructions. Figure 36 –Upload raw configuration file Upgrade 1DXi Firmware Pressing the button ‚Upgrade‘ an upgrade file can be loaded to each LPR®-1DXi unit. Select the upgrade file you received from Symeo.
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation 6 Protocol Description 6.1 General Description This protocol describes the interface between a LPR®-1DXi unit and the user. The binary protocol provides information in high density. Its structure ensures a simple implementation. The transfer is done in single data frames. The interface for the binary protocol is a serial (RS232) interface. The data rate can be programmed to standard values (115200, 38400, 19200, 9600 baud).
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation 6.1.3 CRC The CRC-16-IBM with polynomial x16+x15+x2+1 is used for the checksum. The checksum is calculated over all data fields (TYPE and DATA), but not for the START and END field. The checksum-calculation is only applied to the original symbols. The appropriate calculation for coding must applied before byte stuffing. If receiving the data from the LPR®-1DXi system the byte stuffing must be reserved to get the original symbol.
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation Distance data: 7E 00 10 03 08 02 11 00 00 10 62 00 00 00 7A E6 00 00 AF C4 7F 7E hex START byte 00 hex TYPE (00: Distance Data) 10 03 hex = 00010|0000000001|1 bin 08 02 hex = 00001|0000000001|0 bin 11 = 0001|0001 hex hex = 4194 00 00 00 7A hex = 122 hex 00 hex 00 hex AF C4 7F = 230 Destination LPR address: SID: 1; GID: 1; BBt: 0 (Group Master unit) Antenna port Slave unit: 1 antenna port Group Master unit: 1
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation Content Description Value inside range Distance inside maximum distance range 0x00 outside range Distance outside maximum distance range 0x01 Please take care that the distances for the switching points in your application are within the maximum possible distance range of your version of LPR®-1DXi (see chapter 2.5) 6.3.3 Error Messages The distance data contains an error field which indicates the status of the message.
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation 7 Appendix A: Agency certifications For FCC labeled versions only United States (FCC) and Canada (Industry Canada) Radiofrequency radiation exposure Information: This equipment complies with FCC/IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body.
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation United States (FCC) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
SYMEO Local Positioning Radar System LPR®-1DXi Product Documentation Appendix A: Agency certifications Copyright © Symeo GmbH 2014 Page 38 of 38