Version2.0.
Sybersense Panel Quick-Guide
Catalog Home Security -----------------------------------------------------------------------------------------------------------01 Parts List ------------------------------------------------------------------------------------------------------------------02 Product mechanical design description ---------------------------------------------------------------------------05 Hardware Installation --------------------------------------------------------------------------------------------------11 Home Screen O
About Sybersense Panel: It is your all-in-one home security solution. With an intuitive user interface, voice announcement of open doors and windows, the latest security innovations, we will protect you in your home and when you leave. Easily add new sensors(zones) or life safety devices. Protect your home and loved one’s day and night with your new state of the all-in-one security system.
Parts List Part name Quantity Panel 1 USB power cable and 1 Picture Power supply kit 2
Wall mount bracket 1 Tabletop stand 1 Battery 1 3
USB to Ethernet Adapter 1 User manual 1 4
Product mechanical design description Front Camera: A photo is taken for every intrusion, panic, emergency call, burglar, fire, police or if the wrong user code is entered for 3 times.
Product mechanical design description 6
Product mechanical design description Panel Description-Side 7
Product mechanical design description Panel Description-Back Side 8
Product mechanical design description 9
Product mechanical design description Wake up the screen:When the screen is off, touch the “homebutton” .
Hardware Installation 11
Hardware Installation 12
Screen Overview Home • Home page 13
Screen Overview Home Icon Name Description Settings The Settings page allows user to set the panel and the installer to test before in-stallion. Sensor list The Rooms The Page allows user check the room’s sensors state. Sensor list Page allows user add and edit sensors Index button The Index button displays status of security system and opening sensors Doorbell Camera The doorbell camera page allows the user to connect the doorbell Camera and setting some functions.
Screen Overview Home • Status bar The status bar displays the panel’s current volume, brightness, cellular connection, Wi-Fi, battery level. Icon Name Description Volume The volume icon indicates the panel’s current volume Brightness The brightness icon indicates the panel’s screen. Wi-Fi The icon indicates the panel’s current Wi-Fi strength.
Screen Overview Home • Emergency Calls Emergency call: Press the “Phone” icon and select the type of emergency (Medical, Police or Fire). Press the “Call” button to confirm the call and initiate the call. This process has multiple steps in order to limit the risk of accidentally sending a false alarm signal to the Central Monitoring Station. To cancel an emergency call: Press “Cancel” and enter your pass-code.
Screen Overview Home • advanced security settings 17
Screen Overview Home 18
SW Instructions 1. How to install door sensor 2. How to install window sensor. 3. How to install motion sensor.
SW Instructions • How to add your sensor into your security system and delete it from your system. The devices page allows user to add and modify and delete sensors, the user can check status of each sensors. (Adding Sensors) 1. Click + icon to add new sensors.
SW Instructions 2. Select the type of sensor.
SW Instructions 3. Trigger the sensor at the trigger page 4. Select a name for the sensor after sensor detected 5. Click done to finish or Settings to configure any desired sensor features.
SW Instructions 6. Choosing the sensor type and Access to Groups page allows user check state of the different kind of devices and all devices page allows user check state of all devices.
SW Instructions (To modify the sensor) Access Devices (Settings > Enter Master PIN >Devices) Select the desired items to be configured for the sensor 24
SW Instructions (To remove the sensor) 1. Access Devices (Settings > Enter Master PIN >Devices ) 2. Select the desired sensor and click the to remove.
Product Spec Items Parameters XP02 Panel Platform Android OS V7.1 LCD Display Size 7 inch LCD Resolution 1024 x 600 Brightness 300 cd/m2 RGB 24bit Touchscreen Type Capacitive glass multi-touch Wireless WiFi WiFi 802.11 a/b/g/n/ac dual band 2.
Product Spec Cellular LTE 4G Security R/F Encrypted 433 MHz Bluetooth Bluetooth Low Energy (BLE) 4.
Product Spec Microphone Microphone x 2 Microphone for Voice call, Echo cancellation Internal Siren Piezo Buzzer SPL minimum 85dB Tamper Tamper Switch & Panel tamper switch(with spring release) and G-sensor will report the G-Sensor position and angle change status to the panel Battery Type 3600mAh Li-polymer Reset Reset switch System hardware reset Mechanical Dimension 196.4mm x 136.
Product Spec Temperature UL UL985,UL1023,UL1637,UL 1610, ULC304,ULC545,0SIACP01 Operational -10 to 50 C Storage -40 to 80 C 29
Warning and Warranty 1 The device has two kinds of power supply: power adapter and lithium battery. When the device is powered off, you can not make it power on with lithium battery. You must connect the power adapter to turn on the device normally. The adapter is the main power supply, and lithium battery is only standby. 2 Do not remove the battery from the panel under any circumstances. 3 Do not delete the SIM card’s content under any circumstances.
Warning and Warranty 8 Never expose the panel to moisture. 9 Protect the panel from knocks or blows and excessive heat! Never place the panel on heating devices. 10 Ensure that other people, particularly children, are aware of these risks! Warranty: Within the parameters of the applicable statutory provisions, we provide a warranty for the functioning of the product described in this manual with regard to faults arising in connection with manufacturing defects or material defects.
FCC compliance statement: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.