www.supremainc.com Innovative Fingerprint Terminal User Guide (ver 1.
Innovative Fingerprint Terminal for Access Control and Time Attendance Fingerprint recognition, now look and feel! z Invincible speed and capacity z Using USB memory, copies and backs up user info and event log data very easily. World’s best fingerprint recognition algorithm z Provides various external interfaces including Wi-Fi wireless LAN for easy access to the internal user info and event log from a remote PC.
Before start z z z z Contents z z z Safety precautions Glossary Basics of fingerprint recognition How to place a finger Product contents Name of each part Installation and cable spec.
For Administrators (Advanced functions) z z Display & sound setting Device setup – – – – – – – Contents z Fingerprint setting I/O setting Door relay setting Change master Password View device info Device reset Factory default 35 37 38 39 40 41 42 Log – Check log – Filter log – Delete entire log z 34 USB memory 43 44 45 46 For General Users z Open door – Access using 1:N mode – Access using 1:1 mode z Using T&A event – T&A event using 1:N mode – T&A event using 1:1 mode – Using extended T&A ev
Safety precautions The list below is to keep user’s safety and prevent any loss. Please read carefully before use. Do not install the device in a place subject to direct sun light, humidity, dust or soot. Do not place a magnet near the product. Magnetic objects such a s magnet, CRT, TV, monitor or speaker may damage the device . Do not place the device next to heating equipments. Be careful not to let liquid like water, drinks or chemicals leak inside the device.
Safety precautions The list below is to keep user’s safety and prevent any loss. Please read carefully before use. Do not drop or damage the device. Do not press two buttons at the same time. Do not disassemble, repair or alter the device. Do not let children touch the device without supervision. Do not use the device for any other purpose than specified. Contact your nearest dealer in case of a trouble or problem. 6 Before Start ⒸCopyright 2006 Suprema Inc.
Glossary Administrator z 1:1 Mode z In 1:1 mode, a user should enter his/her user ID first. After then, the user is requested to place a finger or enter a PIN. In this mode, user’s scanned fingerprint is matched against only one fingerprint specified by the user ID. 1:N Mode z A special user who are authorized to manage the settings and user information of a device. Administrators can enroll or delete users and change settings of the device.
Basics of fingerprint recognition What is fingerprint recognition? z z Process of fingerprint recognitioan z z z Fingerprint is an individual’s own biometric information and does not change throughout his/her life. Fingerprint recognition is a technology that verifies or identifies an individual using such fingerprint information. Free from the risk of theft or loss, fingerprint recognition technology is being widely used in security systems replacing PIN or cards.
How to place a finger Suprema’s fingerprint products show an outstanding recognition performance regardless of the user’s fingerprint skin condition or the way of fingerprint positioning. However, following tips are recommended to get more optimal fingerprint recognition performance. Select a finger to enroll z z It is recommended to use an index finger or a middle finger. Thumb, ring or little finger is relatively more difficult to place in a correct position.
How to place a finger Tips for different fingerprint conditions z Suprema’s fingerprint products are designed to scan fingerprint smoothly regardless of the conditions of a finger skin. However, in case a fingerprint is not read well on the sensor, please refer to the followings tips. If a finger is stained with sweat or water, scan after wiping moisture off. If a finger is covered with dust or impurities, scan after wiping them off.
Product Contents Basic Contents Product Contents BioStation fingerprint terminal Wall mounting screws and holders - 3 ea Star-shape screw for fixing main body Wall mounting metal bracket USB cable 5pin, 3pin, 6pin, 4pin, 7pin cable – 1 ea Star-shape small wrench Software CD 11 Before Start ⒸCopyright 2006 Suprema Inc.
Product Contents Optional accessories 12V power adaptor USB memory Plastic stand type A Wireless LAN Access Point Plastic stand type B USB fingerprint scanner for enrollment on PC Interphone 12 Before Start ⒸCopyright 2006 Suprema Inc.
Name of each part Front Microphone Used when connected to interphone. Color LCD Displays terminal status (T&A mode, notice, etc.) and current time. Navigation key ▼ : Move down in Admin menu or view detailed T&A function key ▲ : Move up in Admin menu or hide detailed T&A function key ► : Show the next setting value in Admin menu or input a dot (.
Name of each part Bottom Slot for USB memory device : USB type A Slot for PC USB connection : Mini USB Rear Ethernet cable connector : RJ45 3pin cable connector - Door 6pin cable connector – Input/Output or Wiegand 4pin cable connector - RS485 7pin cable connector - RS232 or BEACon 5pin cable connector – Power and doorphone 12V power adaptor 14 Before Start ⒸCopyright 2006 Suprema Inc.
Installation Installation example 6pin cable PC Network hub Ethernet 3pin cable RS232 7pin cable USB USB Door Lock Exit Button Product dimension (mm) 135 128 50 128 Front 112 88 108 Side Bracket 15 Before Start ⒸCopyright 2006 Suprema Inc.
Cable spec.
For Administrators - Basic Functions Basic information for the device administrators. It includes key items such as basic menu usage, operation mode setting, network connection, and user management. 17 ⒸCopyright 2006 Suprema Inc.
Enter Admin Menu Press ESC key to enter Admin menu from the initial display. ▼ T&A Admin fingerprint or master password OK Enter master password and press OK key. z [Note] As there’s no master password enrolled in a device by factory default, you can enter Admin menu just by pressing OK key. For security reason, set a master password right after the product installation. Please refer to to see how to set a master password.
Using Admin Menu Main functions of initial Admin menu are as follows. For the entire Admin menu list, refer to . z z z z z z To enter a desired submenu from initial Admin menu, move to the desired menu using a navigation key and press OK key. In a submenu, you can move to desired item using up/down navigation key. To change settings of each item, use left/right navigation key. z User : user management such as user enroll/delete/edit. Mode : set device’s operating mode.
Operation mode setting After installation, it is necessary to select an operation mode suitable for its usage. If you select Mode on initial Admin menu, following menus appear on the display. 1:1 Mode z z z 1:N Mode z z z T&A z z z T&A key z z Setting : Finger or PIN/Finger Only/Pin Only After entering ID on 1:1 mode, set whether you will use fingerprint, PIN, or either for authentication.
TCP/IP To use the device connected to PC, you need to set up the network according to your connection type. If you select Network on initial Admin menu, Network Setup menus appear on the display. If you select TCP/IP on network menu, following menus appear on the display. LAN Type Port Server IP DHCP z z z Designate device’s TCP/IP port. Default is 1470. z Designate the IP address of the host PC on which BioAdmin operates.
Wireless LAN To set up the wireless LAN, select the wireless LAN AP. If you press F1 key on TCP/IP menu, following menus appear on the display. Preset z z Select a wireless LAN AP among the preset AP devices. If there is no preset wireless LAN AP, add the wireless LAN AP using BioAdmin program on PC. You can add up to 4 wireless LAN AP. Mode z Shows the operation mode of the wireless LAN AP. ESSID z Shows the ESSID of the wireless LAN AP.
Serial To connect BioStation to the serial port of PC, you need to select the buadrate of the serial communication. To connect the BioStation to the serial port of host PC, designate the buadrate of the serial communication. Serial RS485 RS232 RS485 z z z z z RS232 z z ◁ ◀ 115200 115200 ▷ ▶ Setting :Disable/9600/19200/38400/57600/115200 Used when connecting to the serial port of PC using 7pin connector on the rear of the device.
USB To connect the BioStation to the USB port of host PC, enable the USB communication. If you select USB on network submenu, USB setting menu appears on the display. USB USB Port USB z z z ◁ Disable ▷ Setting : Enable/Disable Used to connect the mini USB port on the bottom of the device to the USB port of PC. [Note] For security reasons, USB is set as Disable by the factory default. When you connect device to PC using USB, the setting should be changed to Enable in advance.
Enroll New User How to enroll the user information and fingerprint. If you select User on initial Admin menu, User Management menus appear on the display. User Management Enroll User Edit User Delete All Users Check User DB If you select Enroll User on user menu, following menus appear on the display. User ID z z z Admin Level z z z Password Group 1 ~ Group 4 By default, the lowest available ID is displayed on the ID part of the menu. Enter your desired ID.
Enroll New User If you enter all the necessary items for enrollment and press OK key, the following fingerprint menus appear on the display. Enroll Finger Finger No Duress Finger No z z z z z Duress z z z z z ◀ 1 None ▶ Setting : 1/…/5/None 1-5 fingers can be enrolled for each ID. Enrolling more than two fingers per user can be useful in a case of injury of a finger. For a user whose fingerprint is weak or worn-out, enrolling the same finger twice or more can reduce failure rate.
Enroll New User After selecting Finger No. and Duress and pressing OK, now you should place a finger on a sensor for enrollment. z z z z z For enrollment, the same finger should be placed twice according to the messages shown in the display. If Finger No. is set more than 2, the device asks for the scan of the next fingerprint continously. After placing a finger on a sensor, user can see the captured fingerprint image on the display.
Check User Info Check user info of currently enrolled users. If you select Edit User on User Management menu, user info of each users are displayed. You can change user ID using a left/right navigation key. If you enter user ID with the numeric key, you can directly move to the user info the entered user ID. z If there is no user with the selected ID, “None” message is indicated on the Name field of the display.
Edit User Info User info can be changed and fingerprints can be re-enrolled. If you press OK key at Edit User menu, the selected user info is displayed and can be edited in the same way as in the Enroll User process. You can change admin level, password and groups. If you want to re-enroll fingerprints of the user, press F2 key at Edit User menu. You can select the number of fingerprints and duress and then re-enroll fingerprints.
Delete User Delete user from device while checking currently enrolled user info. If you want to delete the user, press F3 key at Edit User menu. Press OK key to confirm the deletion of the user. z [Note] Deleted user info can’t be retrived unless the info remains in BioAdmin software on PC. Edit User F1 More Do you want to delete this user? OK ESC 30 For Administrators - Basic Functions ⒸCopyright 2006 Suprema Inc.
Delete All Users Delete all user currently enrolled in device. Back to User Management menu, select Delete All User to delete all users in the device. User Management Do you want to delete all users? OK ESC Press OK key to confirm the deletion of all users. z z [Note] Once all users are deleted, deleted user info cannot be retrived unless the info remains in BioAdmin software on PC. [Note] The data of administrators who is operating the menu is also deleted by this operation.
Check User DB Check and correct errors in the user information stored on device. If you press Check User DB on User menu, following menus appear on the display. User Management Do you want to check user DB errors? OK ESC Press OK key to check the user DB. z If there is an error on the user DB, it will be automatically corrected by this procedure. If it fails to corret, an error message appear on display. 32 For Administrators - Basic Functions ⒸCopyright 2006 Suprema Inc.
For Administrators - Advanced Functions Detailed information for device administrators. It includes specific items such as display and sound setting, fingerprint authentication setting, and log check. 33 ⒸCopyright 2006 Suprema Inc.
Display & Sound Setting Change device’s display and sound settings. If you select Display on initial Amin menu, following menus will appear on the display. z Language z z Background z z z z Sub Info Timeout z z z Date z Time z Volume z z Setting :Korean/English/Custom Select a language to be used To use custom language, appropriate language config. file needs to be downloaded to the device using BioAdmin program on PC. Please contact Suprema for details.
Fingerprint Setting Change various settings for fingerprint authentication. If you select Device on initial Admin menu, Device Setup menus appear on the display. Device Setup Fingerprint I/O Door Relay Master Password Device Info Device Reset Factory Default If you select Fingerprint, following menus appear on the display. In this manual, the default setting is in bold font. Security z z z Setting : Normal/Secure/Most Secure Security level is determined by FAR (False Acceptance Ratio).
Fingerprint Setting Fast Mode Quality View Image z z z z z z z Sensitivity z z Timeout(Sec) Encryption z z z z Setting : Normal/Fast/Fastest Using 1:N mode with more than hundreds of users, identification may take somewhat longer. In this case, you can change the fast mode to Fast or Fastest. By doing so, identification speed becomes faster in sacrifice of a little higher FRR. Setting: Weak/Normal/Strict Quality level decides the strictness of quality check of the input images.
I/O Setting Change various settings for I/O. If you select I/O on device menu, following menus appear on display. Input 0 & Input 1 z z z Output 0 & Output 1 z z z Duration(ms) Tamper S/W Setting : Disabled/Exit/Wiegand In case of using the input port for RTE(exit button), select Exit. In case of using input as Wiegand, input 0 and input 1 are set as Wiegand. Set the cycle of output signal. Default is 1sec (1000ms).
Door Relay Setting Change various settings for door relay. If you select Door Relay on device menu, following menus appear on the display. Driven by z z z z Setting : All Event/Selected T&A/Disabled In case of All Event, door opens for all authenticaiton success events.(1:1 PIN auth., 1:1 fingerprint auth., 1:1 finger scan). In case of Selected T/A, door opens only by the specific events for which door use is allowed. It also opens in case of authorization without T&A event.
Change Master Password Change master PW. If you select Master Password on device menu, Master Password menus appear on the display. Master Password Current New New(Again) Enter current master password to “Current” and a new master password to “New” & “New (again)”. Then press OK key to confirm. z z Default password is blank (no need to type). [Note] With this master password, one can enroll or delete users and change settings of BioStation.
View Device Info View device’s basic info such as model name and version. If you select Device Info on device menu, following menus appear on the display. z Model name is displayed according to types of fingerprint sensor. Optical sensor : BST-OC Capacitive sensor : BST-TC Thermal swipe sensor : BST-FC Device ID z Device ID number is displayed. MAC z Device’s Ethernet MAC address is displayed. HW Version z Device’s hardware version is displayed.
Device Reset Reset system. If you select Device Reset on device menu, a message to restart BioStation appears on the display. Press OK key to reset device. Device reset takes normally 20-30 seconds and it mayy take a bit longer for network connection. If you change language of BioStation, you should reset BioStation to apply the new language. If device becomes unstable for any reason, in maycases, device reset can solve the problem.
Factory Default Restore device’s all settings to factory defaults. If you select Factory Default on device menu, a message to reset to default appears on the display. Device Setup Do you want to reset to default? OK Press OK key to change system’s various settings as factory defaults. z ESC [Note] Be sure that various settings, background, sounds and notice will be deleted. User info and log data are not deleted. To delete user info, refer to .
Check Log Check logs for various events accumulated in device. If you select Log on initial Admin menu, log events appear on the display. You can check logs from the latest one.
Filter Log Check specific log events by filtering the log events stored on device. If you press F2 key on Log meny, following menus appear on the display. Filter ID Time z z z z Event T&A Event User Select the filter ID. Device can store up to 4 filters. Filter ID Time Event T&A Event User ◁ ◀ ◀ ◀ 1 All All All ▷ ▶ ▶ ▶ 0 Setting : All/Today/Yesterday/Last 3 days/Last 1 week/Last 1 month Designate the time to filter.
Delete Entire Log Delete entire event logs accumulated in device. If you press F3 on log list screen, a message to delete all logs appears on the display. Log List F1 More Do you want to delete all logs? OK ESC Press OK key to delete all logs. z [Note] Be sure that a deleted log can not be retrived unless it remains in BioAdmin program on PC. 45 For Administrators - Advanced Functions ⒸCopyright 2006 Suprema Inc.
USB Memory How to use USB memory to transfer user information, log data, and various settings of device. If you select USB Memory on Network menu, folloing menus appear on the display. When you are using wireless LAN, the wireless LAN is automatically disconnected in this menu. When you go out of this menu, wireless LAN is reconnected.
USB Memory How to use USB memory to transfer user information, log data, and various settings of device. Import Virtual Terminal z z z z z z Firmware Upgrade z z z z Initialize z z Refresh z Apply the user information and various settings in USB memory to the connected device. Import starts by selecting the an ID of the virtual terminals on USB memory.
For General Users Describes directions for general users. It explains how to open a door in each operation mode and to enter T&A events. 48 ⒸCopyright 2006 Suprema Inc.
Access using 1:N mode How to open a door using fingerprint when 1:N mode is set as Auto or OK/T&A key. When 1:N mode is set as Auto z ▼ T&A If you enter a fingerprint without pressing any key, a message showing the identification result appears and door is opened. Welcome! Tommy When 1:N mode is set as OK/T&A key z z If you press OK or T/A key, blue LED flickers and a message requesting user’s fingerprint appears on the display. Place a finger to open the door.
Access using 1:1 mode How to open a door by entering ID first and then entering fingerprint or password. If you press a numeric key, ID input window appears. ▼ T&A User ID 1234 Enter your ID and press OK key. In case 1:1 mode is set as Fingerprint Only z In case 1:1 mode is PIN Only z Enter a fingerprint to open the door. Enter your password and press OK key to open the door.
T&A event using 1:N mode How to enter T&A events with fingerprint when 1:N mode is set as Auto or OK/T&A key, and T&A is set as Enabled. If you press F1~F4 key, blue LED flickers and a message requesting user’s fingerprint appears on the display. ▼ T&A T&A: In Place your finger If you place a finger, designated T/A event appears on the display and applies to the user.
T&A event using 1:1 mode How to enter T&A event by first entering ID and then entering fingerprint or password when T&A is set as enabled. If you press a numeric key, ID input window appears on the display. ▼ T&A User ID 1234 Enter your ID and press F1~F4. In case 1:1 mode is set as Fingerprint Only z In case 1:1 mode is set as PIN Only z Enter fingerprint to apply applicable T&A event. Enter your PW and press OK key to apply applicable T&A event.
Using extended T&A events In case of using 4 or more T&A events, you can use extended T&A events. If you press down navigation key, extended T&A events info appears on the display. 1 2 3 F1 In 4 5 6 F2 7 8 9 F3 ESC F4 CALL 0 In duty Out duty If you press one of 16keys corresponding to the desired T&A event, next operation starts for the extended T&A event. Factory default T&A events are defined as below.
View user’s Access/T&A event records General users can check their own access and T&A event records. If you press ESC key on initial screen, a message requesting user fingerprint or password appears on the display. ▼ T&A Admin fingerprint or master password OK If user enter his/her fingerprint or password, access and T&A event records displays as below.
Authentication procedure for each operation mode Open door 1:N mode OK fingerprint (skip in case of Auto setting) fingerprint (finger scan) 1:1 mode ID OK PW+OK (auth. PW) F1~F4 T&A event (default T&A event) 1:N mode fingerprint Down key+16key (extended T&A event) 1:1 mode ID F1~F4 fingerprint (default T&A event) (finger scan) Down key+16key PW+OK (extended T&A event) (auth. PW) 55 For General Users ⒸCopyright 2006 Suprema Inc.
List of Admin Menu Enroll User User User ID Admin Level Passwor Group 1 Group 2 Group 3 Group 4 Fingerprint Device I/O Input 0, Input 1 Output 0, Output 1 Duration(ms) Tamper SW Finger No duress Edit User OK: Edit User F2: Finger F3: Delete Door Relay Delete All users Check User DB Mode Display Log Master Password Device info Device Reset Factory default 1:1 Mode 1:N Mode T&A T&A key Language Background Sub Info Timeout Date Time Volume OK: Latest F2: Filter Log F3: Delete Driven by Durati
Specifications CPU : Dual CPU (32 bit RISC + 400MHz DSP) Memory : 72MB flash + 34MB RAM Display : 2.5 inch QVGA 16 million color LCD Identify 3,000 fingerprints in 1 sec.
Troubleshooting Fingerprint can not be read well or it takes too long. z z z Fingerprint is entered but authorization keeps failing. z z z z z Check whether the time is set as lock time. Check ‘driven by’ on Admin menu. In case it is set as disabled or selected T/A events, door may not open. Partial key can’t be entered or device is unstable. z Check whether the user is restricted by door zone or time zone.
Device cleaning Wipe out machine surface with dry towel or cloth. In case there is dust or impurities on the sensor of the BioStation, wipe off the surface with dry towel. Note that if the sensor is cleaned by detergent, benzine or thinner, surface is damaged and fingerprint can’t be entered. 59 Appendix ⒸCopyright 2006 Suprema Inc.
CAUTION: Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user’s authority to operate the equipment WARNING This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Suprema Inc. 16F Parkview Office Tower, Jeongja-dong, Bundang-gu, Seongnam, Gyeonggi, 463-863 Korea E-mail : support@supremainc.com Website : www.supremainc.com Technical Support Inquiry Functions and specifications of the product are subject to changes without notice due to quality enhancement or function update. For any inquiry on the product, please contact Suprema Inc.