BioEntry™ Installation Guide BioEntry™ Smart / Pass Ver. 0.96c Suprema Inc and BioEntry™ are registered trademarks of Suprema Inc. All rights reserved. No part of this work covered by the copyright hereon may be reproduced or copied in any form or by any means - graphics, electronic, or mechanical, including photocopying, recording, taping, or information and retrieval systems - without written permission of Suprema Inc.
BioEntry Smart/Pass BioEntry Installation Guide 2 Suprema Warranty Policy Suprema warrants to buyer, subject to the limitations set forth below, that each product shall operate in substantial accordance with the published specifications for such product for a period of one (1) year from the date of shipment of the products (“Warranty Period”).
BioEntry Smart/Pass BioEntry Installation Guide 3 Disclaimers Information in this document is provided in connection with Suprema products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document.
BioEntry Smart/Pass BioEntry Installation Guide 4 product order. Note: Third-party brands and names are the property of their respective owners. About the BioEntry™ Series BioEntry™ is an advanced biometric access reader equipped with award winning fingerprint recognition engine and standard wiegand interface. BioEntry™ can practically replace legacy and simple readers and be instantly added onto existing access control systems as well as new installations.
BioEntry Smart/Pass BioEntry Installation Guide 5 About Suprema Inc Suprema is a leading biometric company offering core fingerprint technologies for embedded and PC applications. Suprema’s fingerprint products include low cost standalone OEM modules, access control readers, USB fingerprint scanners and fingerprint algorithm SDK.
BioEntry Smart/Pass BioEntry Installation Guide 6 Contents 1. Before you start with BioEntry™ ............................................................................9 1.1. Included items......................................................................................................... 9 1.2. Required items........................................................................................................ 9 1.3. Optional items.................................................................
BioEntry Smart/Pass 4.1.3. BioEntry Installation Guide 7 Data storage................................................................................................. 20 4.2. Mechanical Specifications...................................................................................... 20 4.2.1. Operating range ............................................................................................ 20 4.2.2. Absolute Maximum Ratings ....................... 오류! 책갈피가 정의되어 있지 않습니다. 4.2.3.
BioEntry Smart/Pass BioEntry Installation Guide 8 Figures Figure 1> A full duplex BioEntry network.............................................................1 3 Figure 2> A half duplex BioEntry network.............................................................1 4 Figure 3> Connecting stereo plug to DB-9 cable ... 오류! 책갈피가 정의되어 있지 않습니다. Figure 4> Auxiliary port................................. 오류! 책갈피가 정의되어 있지 않습니다. Figure 5> Aux. enable switch.......................... 오류! 책갈피가 정의되어 있지 않습니다.
BioEntry Smart/Pass BioEntry Installation Guide 9 1. Before you start with BioEntry™ 1.1. Included items l A BioEntry Smart/Pass unit l A stereo plug to DB-9 cable l This Installation Guide 1.2. Required items l A DC power supply rated at 12V @ 500mA l An access control panel with Wiegand input port 1.3. Optional items l A reader with Wiegand output port Copyright © 2005 by Suprema Inc. http://www.supremainc.
BioEntry Smart/Pass BioEntry Installation Guide 2. Installing BioEntry™ 2.1. Connecting wires 10 The BioEntry is connected to other devices of the security system through the pigtail cable at the rear side. See Table 1 for wire colors and signals.
BioEntry Smart/Pass BioEntry Installation Guide 11 Table 1> BioEntry wire colors Warnings: Care should be taken identifying the wires. Improper wiring may render permanent damage to the device or personal injury. 2.2. Power connection Use ‘POW+’ and ‘POW_GND’ wires to connect BioEntry to a DC supply, rated at 9~24V, 500mA. The power cable should be as short as possible to minimize wire resistance and emissions.
BioEntry Smart/Pass 2.4. BioEntry Installation Guide 12 Connecting to a Wiegand compatible access controller The BioEntry supports a flexible Wiegand output interface for most access controllers with Wiegand input ports. Connect ‘WOUT_D0’, ‘WOUT_D1’ and ‘WOUT_GND’ wires to ‘Data 0’, ‘Data 1’ signals and signal ground of the access controller, respectively. If the access controller’s input signal level exceeds 5.0V, apply required voltage to ‘WOUT_VREF’ to obtain higher voltage output signals.
BioEntry Smart/Pass BioEntry Installation Guide BioEntry TX+ TXRX+ RX- BioEntry TX+ TXRX+ RX- BioEntry TX+ TXRX+ RX- RS-232 PC RX+ RXTX+ TX- Termination Resistors RS-485 Converter 13 Connect cable shield to earth GND at one point only Termination Resistors Figure 2> A full duplex BioEntry network Warnings: To prevent ground loops and avoid communication problems, connect cable shield to earth GND at only one point. 2.5.3.
BioEntry Smart/Pass BioEntry Installation Guide 14 At each end of the network, termination resistors of 120ohms should be connected between ‘+’ and ‘-’ signals for proper impedance matching.
BioEntry Smart/Pass 2.6. BioEntry Installation Guide 15 Disassembling Remove screw at bottom of the BioEntry. Figure 4> Removing the screw Lift bottom of the housing, slide up and carefully remove it. Figure 5> Separating the case Copyright © 2005 by Suprema Inc. http://www.supremainc.
BioEntry Smart/Pass 2.7. BioEntry Installation Guide 16 Mounting back plate Install back plate to wall surface. Figure 6> Installing back plate to the wall 2.8. Reassembling the BioEntry Figure 7> Reassembling the case Copyright © 2005 by Suprema Inc. http://www.supremainc.
BioEntry Smart/Pass 3. BioEntry Installation Guide 17 Examples for BioEntry™ installation The BioEntry Smart/Pass offers various interfaces such as Wiegand input/output, general purpose I/O signals and communication ports that can be easily implemented to a security system, improving the security level. 3.1. Building a new system The BioEntry Smart/Pass is compatible with most access controllers with Wiegand interface.
BioEntry Smart/Pass BioEntry Installation Guide 18 simplifies user management process and improves overall security, as the biometric data are physically isolated from the BioEntry, protecting them against possible vandalism. Moreover, as the user management process does not rely on network installation, total cost for installation is minimized. 3.2.
BioEntry Smart/Pass BioEntry Installation Guide Network Actuator / Lock device Data 0 Data 1 GND Wiegand IN Data 0 Data 1 GND Wiegand OUT BioEntry Pass Access Controller Actuator / Lock device Network To other controllers or host computer Wiegand Reader To other BioEntry readers or host computer Access Controller To other controllers or host computer Data 0 Data 1 GND Wiegand signals Wiegand Reader 19 TX+ , RX+ TX- , RXTRX+ TRX- Figure 9> Adding BioEntry Pass to existing system Copyrigh
BioEntry Smart/Pass BioEntry Installation Guide 4. Specifications 4.1. Fingerprint Authentication Specifications 4.1.1. Fingerprint Authentication Performance EER* <0.1% Enrollment time <1 sec Verification time <1 sec 20 *EER is dependent on specific database 4.1.2.
BioEntry Smart/Pass 4.3. 4.4. 4.5. BioEntry Installation Guide Parameter Symbol Min Typ. Max Units Supply current IDD 200 500 mA Wiegand Input Port Symbol Min Typ. Max Units High level input voltage VWIH 3.3 12 V Low level input voltage VWIL -0.3 2.0 V Wiegand Output Port Symbol Min Max Units High level output voltage VOH 5.0 V Low level output voltage VOL 0.0 V Current source/drain IO -1/20 mA Typ.
BioEntry Smart/Pass BioEntry Installation Guide 22 Contact Information Suprema Inc. DongCheon Bldg. 13-21 Yangjae-dong Seocho-gu Seoul 137-130 Korea Tel: +82-2-571-9202 Fax: +82-2-571-9306 Website: http://www.supremainc.com Sales inquires : sales@supremainc.com Technical inquires : support@supremainc.com Copyright © 2005 by Suprema Inc. http://www.supremainc.