BioEntry W IP Based Fingerprint Access Control Installation Guide (Ver 0.1) 0 1) www.suprema.co.
BioEntry W Contents Safety precautions 3 Basics of fingerprint recognition 5 How to place a finger 6 Product d Contents 8 Front Side 10 Bottom and Back Side 11 Product Dimension 12 Cables and Connectors 13 Installation of Wall-mount Bracket 14 Power Connection 15 Ethernet Connection 16 RS485 Connection 18 Relay Connection 20 Digital Input Connection 23 Wiegand Output 25 Network Default Setting 26 Installation Reference 27 Electrical Specification 30 Troubleshooting 31
BioEntry W Safety precautions The list below is to keep user’s safety and prevent any loss. Please read carefully before use. Do not install the device in a place subject to direct sun light, humidity, dust or soot. Do not place a magnet near the pr oduct. Magnetic objects such as magnet, CRT, TV, monitor or spe aker may damage the device. Do not place the device next to heating equipments. Be careful not to let liquid like water, drinks or chemicals leak inside the device.
BioEntry W Safety precautions The list below is to keep user’s safety and prevent any loss. Please read carefully before use. Do not drop the device. Do not damage the device. Do not disassemble, repair or alter the device. Do not let children touch the device without supervision. Do not use the device for any other purpose than specified. Contact your nearest dealer in case of a trouble or problem. 4 ⒸCopyright 2007 Suprema Inc.
BioEntry W Basics of fingerprint recognition What is fingerprint recognition? z z Process of fingerprint recognition z z z Fingerprint g p is an individual’s own biometric information and does not change g throughout g his/her life. Fingerprint recognition is a technology that verifies or identifies an individual using such fingerprint information. Free from the risk of theft or loss, fingerprint recognition technology is being widely used in security systems replacing PIN or cards.
BioEntry W How to place a finger Suprema’s fingerprint products show an outstanding recognition performance regardless of the user’s fingerprint skin condition or the way of fingerprint positioning. However, following tips are recommended to get more optimal f fingerprint recognition performance. f Select a finger to enroll z z It is recommended to use an index finger or a middle finger. Thumb ring or little finger is relatively more difficult to place in a correct position Thumb, position.
BioEntry W How to place a finger Tips for different fingerprint conditions z Suprema’s p fingerprint g p p products are designed g to scan fingerprint g p smoothly y regardless g of the conditions of a finger skin. However, in case a fingerprint is not read well on the sensor, please refer to the followings tips. If a finger is stained with sweat or water, scan after wiping moisture off. If a finger is covered with dust or impurities, scan after wiping them off.
BioEntry W Product Contents Basic Contents BioEntry W Wall mounting screws – 2 ea Star-shaped Star shaped screws Star-shaped small wrench Software CD Wall-mounting metal bracket 8 ⒸCopyright 2007 Suprema Inc.
BioEntry W Product Contents Optional accessories Secure I/O 12V power adaptor Plastic stand USB fingerprint scanner for enrollment on PC 9 ⒸCopyright 2007 Suprema Inc.
BioEntry W Front Side Front LED Status per Color LED Display current status using seven different colors RF card reading part Place an RF card over the picture Fingerprint sensing part Place a finger on a sensor surface f z Green : Authorization Success z R d:A Red Authorization th i ti F Failil z Pink : On Processing z Flicker Blue/Sky-Blue Color per 2sec : Normal z Flicker Red/Pink Color per 2sec : Locked z Flicker Blue/Red Color per 2sec : Initialized Time due to the Internal Battery Dis
BioEntry W Bottom and Back Side Star-shaped screw hole for fixing a body to a metal bracket wiegand input or wiegand output power and RS485 ethernet (TCP/IP) digital input and relay output Network Indicate LED switch it h : Network N t kR Resett (Refer to “Network Default Setting” pages for details) 11 ⒸCopyright 2007 Suprema Inc.
BioEntry W Product Dimension 50 172 172 Front 40 44 157 Side Metal Bracket (unit : mm) 12 ⒸCopyright 2007 Suprema Inc.
BioEntry W Cables( all cables use the shielded cables) 13 ⒸCopyright 2007 Suprema Inc.
BioEntry W Installation of Wall-mount Bracket Fix wall mount bracket on a wall using wall mounting screws Hook BioEntry W on the wall mount bracket Wall mounting screws Fix BioEntry W and wall mounting bracket using a star shape screw. Star-shaped screw Star-shaped wrench ⒸCopyright 2007 Suprema Inc.
BioEntry W Power Connection UPS (optional) DC Power supply RS-485 Power 12V (Red) Power GND (Black) Signal GND (Black/White) TRX+ (Blue/White) TRX (Yellow/White) TRXBioEntry W Recommended power supply z 12V ± 10%, 10% att lleastt 500 500mA. A z Comply with standard IEC/EN 60950-1. z To share the power with other devices, use a power supply with higher current ratings. 15 ⒸCopyright 2007 Suprema Inc.
BioEntry W Ethernet Connection 16 ⒸCopyright 2007 Suprema Inc.
BioEntry W Ethernet Connection (Direct connection with PC) To connect BioEntry W with a PC directly, connect both devices with a straight CAT-5 cable. As the BioEntry W supports auto MDI/MDIX feature, it is not necessary to use a crossover type cable. 17 ⒸCopyright 2007 Suprema Inc.
BioEntry W RS485 Connection for Host Communication (Black/White) (Blue/White) (Yellow/White) W (Black/White) (Blue/White) (Yellow/White) W 18 ⒸCopyright 2007 Suprema Inc.
BioEntry W RS485 Connection for Secure I/O (Black/White) (Blue/White) (Yellow/White) W (Black/White) (Blue/White) (Y ll /Whit ) (Yellow/White) W Max number of devices z Maximum numbers of devices in an RS485 loop are two(2) devices (BioStation or BioEntry W) and four(4) Secure I/Os 19 ⒸCopyright 2007 Suprema Inc.
BioEntry W Relay Connection – Fail safe lock 20 ⒸCopyright 2007 Suprema Inc.
BioEntry W Relay Connection – Fail secure lock 21 ⒸCopyright 2007 Suprema Inc.
BioEntry W Relay Connection - Automatic door RTE Switch Presence Detector BioEntry W Automatic A t ti Door D Door Controller (7) Normally N ll O Open / N.O. N O (Gray/White) (G /Whit ) (6) Common (GREEN/White) (5) Normally Closed / N.C. (Orange/White) 22 ⒸCopyright 2007 Suprema Inc.
BioEntry W Digital Input Connection (RTE, Door sensor) 23 ⒸCopyright 2007 Suprema Inc.
BioEntry W Digital Input Connection (Alarm, Emergency sw) BioEntry W ( ) SW1 GND ((Black/White)) (4) (3) SW1 Input (Brown) (2) SW0 GND (Black/White) (1) SW0 Input (Purple) Switch #1 Switch #2 24 ⒸCopyright 2007 Suprema Inc.
BioEntry W Wiegand Input/Output Wiegand ega d Input put Wiegand Output 25 ⒸCopyright 2007 Suprema Inc.
BioEntry W Network Default Setting In case of forgetting network setting of BioEntry W (TCP/IP or RS-485 setting) during installation or using BioEntry W, user can initialize network setting (TCP/IP or RS-485 setting) by using DIP SW installed on the back panel of BioEntry W. Please refer to the figures in below. g How to initialize Network Setting z 1. Turn On BioEntry W power. z 2. Please push the Switch (Please refer to Fig.1) z 3.
BioEntry W Installation Reference 1 - Stand alone Door Sensor Door Lock Exit Button BioEntry W LAN PC Enroll Scanner 27 ⒸCopyright 2007 Suprema Inc.
BioEntry W Installation Reference 2 – Secure RS485 Door Sensor Door Lock Exit Button Secure I/O BioEntry W LAN PC Enroll Scanner 28 ⒸCopyright 2007 Suprema Inc.
BioEntry W Installation Reference 3 – Network Door Zone 1 (Anti passback) RS485 BioStation RS485 BioEntry W BioEntry W Secure I/O LAN PC S Server Enroll E ll Scanner S PC Client BioStation Secure I/O BioEntry W Exit Button RS485 PC Client Door Zone 2 (Anti passback) 29 ⒸCopyright 2007 Suprema Inc.
BioEntry W Electrical Specification Min. Typ. Max. Notes 10.8 12 13.2 Use regulated DC power adaptor only Power Voltage (V) Current (mA) - 250 Switch Input VIH (V) - TBD VIL (V) - TBD Pull-up resistance (Ω) - 4.7k - VOH (V) - 5 - VOL (V) - 0.8 - P ll Pull-up resistance i t (Ω) - 4 7k 4.7k - Switching capacity (A) - - 1 0.3 Switching power (resistive) - - 30W 37.5VA DC AC Switching voltage (V) - - 110 125 DC AC - The input ports are pulled up with 4.
BioEntry W Troubleshooting Fingerprint can not be read well or it takes too long. z z z Fingerprint is entered but authorization keeps failing. z z Check whether the user is restricted by door zone or time zone zone. Inquire of administrator whether the enrolled fingerprint has been deleted frin the device for some reason. Authorized but door is not opened.
BioEntry W Device cleaning Wipe out machine surface with dry towel or cloth. In case tthere e e is s dust o or impurities pu t es o on tthe e se sensor so o of tthe e BioStation, oStat o , wipe pe o off the t e surface su ace with t dry towel. Note that if the sensor is cleaned by detergent, benzene or thinner, surface is damaged and fingerprint can’t be entered. 32 ⒸCopyright 2007 Suprema Inc.
BioEntry W FCC Rules z Changes or modifications not expressly approved by the manufacturer responsible p could void the user's authority y to operate p the equipment. q p for compliance z RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE z DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS Warning z This device complies with part 15 of the FCC Rules.
BioEntry W Specifications Item Specification CPU 400MH DSP 400MHz Fingerprint sensor 500dpi Optical / Capacitive sensor User capacity 5000 users (10,000 templates) Log capacity 50,000 events Matching speed Less than 1 second Operation mode Fingerprint, RF Card, RF card + Fingerprint Network Interface TCP/IP, RS485 Internal relay Deadbolt EM lock Deadbolt, lock, door strike strike, automatic door TTL I/O 2 inputs for exit switch and door sensor Wiegand In/Out 1 Port (Wiegand Input or Wie
Suprema Inc. 16F Parkview Office Tower, Jeongja-dong, Bundang-gu, Seongnam, Gyeonggi, 463-863 Korea E-mail : support@supremainc.com Website : www.supremainc.com www supremainc com Functions and specifications of the product are subject to changes without notice due to quality enhancement or function update. update For any inquiry on the product product, please contact Suprema Inc.