BioEntry W Compact Outdoor Fingerprint Reader/Controller Installation Guide Version V1.0 www.supremainc.
BioEntry W Important Safety Information Carefully review the information within the user manual before installing/operating the device. Pay careful attention to the warning and cautions below as they are here to prevent any risk/damage to any person(s) or property associated with the device. Warning Failure to heed these warnings may lead to serious injury or even death! Installation Do not install the device near heat sources such as radiators, heat registers, and stoves.
BioEntry W Contents About Fingerprint Recognition 4 How to Enroll a Fingerprint on the Device 5 Components 7 Product Description 9 Dimensions 11 Cable Specifications 12 Installation 13 System Configurations 14 Connections 17 Resetting Network Settings 28 Electrical Specifications 29 Product Specifications 30 Troubleshooting 31 Precautions for Device cleaning 32 FCC Rules 33 ⒸCopyright 2007 Suprema Inc.
BioEntry W About Fingerprint Recognition What is a fingerprint? Fingerprints are individual’s own biometric information and do not change throughout one’s life. Fingerprint recognition is a technology that verifies or identifies an individual using such fingerprint information. Free from the risk of theft or loss, fingerprint recognition technology is being widely used in security systems replacing PIN or cards. What is fingerprint recognition? Fingerprints consist of ridges and valleys.
BioEntry W How to Enroll a Fingerprint on the Device Suprema's fingerprint products have outstanding recognition performance regardless of the user's fingerprint condition or positioning. However pay careful attention to the following instructions to maximize the performance of the device. Fingerprint Enrollment It is recommended to enroll the index or middle finger. The thumb, ring or little finger are generally more difficult to position properly.
BioEntry W How to Enroll a Fingerprint on the Device Fingerprint Enrollment Precautions Operational Warnings If a finger is wet or too moist, wipe off the moisture then try the scan again. If a finger is covered with dust or impurities, clean the finger then try the scan again. If a finger is dry, breathe warm air onto the finger then try the scan again. Solving Authentication Difficulties Delete then Re-enroll the finger. Enroll the same finger multiple times.
BioEntry W Components Basic Components Wall Mount Screws (2) Wall Mounting bracket (1) Main Unit Mounting Screws (2) Software CD (1) BioEntry W ⒸCopyright 2007 Suprema Inc.
BioEntry W Components Optional Accessories Secure I/O 12VDC Power Adaptor Plastic Stand USB Fingerprint Scanner ⒸCopyright 2007 Suprema Inc.
BioEntry W Product Description Front LED Displays the current status with various colors. RFID Scanner Place an RFID card over the scanner. Fingerprint Sensor Place a finger on the surface of the sensor.
BioEntry W Product Description Rear and Bottom Cables Wiegand Input/Output Cables Power Cables RS485 Cables Ethernet Connector Input Cables Relay Cables LED Network Status LED Network Reset Switch See "Resetting Network Settings (page 28)" for more details. Star-shaped screw hole for fixing a body to a metal bracket ⒸCopyright 2007 Suprema Inc.
BioEntry W Dimensions BioEntry W 44 mm 172 mm 50 mm Wall Mounting Bracket 40 mm 172 mm 157 mm ⒸCopyright 2007 Suprema Inc.
BioEntry W Cable Specifications PIN Description Color 1 SWIN1 BROWN 2 SWIN0 PURPLE 3 ETH TXP WHITE 4 ETH TXN ORANGE 5 ETH RXP BLACK 6 ETH RXN YELLOW 7 POWER IN RED 8 POWER GND BLACK PoE VB2 BLUE PoE VB2 BROWN PoE VB1 RED PoE VB1 GREEN 11 485 TRXN YELLOW/WHITE STRIPE 12 485 TRXP BLUE/WHITE STRIPE 13 485 GND BLACK/WHITE STRIPE 14 WIEGAND GND WHITE/BLACK STRIPE 15 WIEGAND D1 WHITE 16 WIEGAND D0 GREEN 17 NC PINK 18 RELAY NC ORANGE/WHITE STRIPE 19 RELAY
BioEntry W Installation 1. Fix the wall mounting bracket on a wall by using wall mounting screws. 3. Fix the device to the wall mounting bracket using the star-shaped screws. 2. Hook the device on the wall mount bracket. Star-shaped screw Wall Mount Screws ⒸCopyright 2007 Suprema Inc.
BioEntry W System Configurations Standard Door Sensor Door Lock Exit Button BioEntry W LAN PC USB Fingerprint Scanner ⒸCopyright 2007 Suprema Inc.
BioEntry W System Configurations Secure (Secure I/O) RS485 Door Sensor Door Lock Exit Button Secure I/O BioEntry W LAN PC USB Fingerprint Scanner ⒸCopyright 2007 Suprema Inc.
BioEntry W System Configurations Network Door Zone 1 (Anti-passback) RS485 RS485 Secure I/O FaceStation BioEntry W BioEntry W LAN PC Server USB Fingerprint Scanner PC Client FaceStation Secure I/O BioEntry W Exit Button RS485 PC Client Door Zone 2 (Anti-passback) ⒸCopyright 2007 Suprema Inc.
BioEntry W Connections Power Connection DC Power UPS (Optional) Supply DC Power Supply Recommended Power Specifications − 12V ±10%, at least 500mA. − Comply with standard IEC/EN 60950-1. − When sharing power with other devices, use a power supply with a higher current rating. ⒸCopyright 2007 Suprema Inc.
BioEntry W Connections Ethernet Connection (Connection with HUB) The device can be connected with a regular hub or PoE hub by connecting the Ethernet cable to the Ethernet terminal. PoE(Power over Ethernet) is an Ethernet connection of which the power is supplied from PSE(Power Sourcing Equipment) satisfying the IEEE802.3af standard. Ethernet Hub ⒸCopyright 2007 Suprema Inc.
BioEntry W Connections Ethernet Connection (Direct connection with PC) Use a standard CAT-5 cable to connect the device directly to a PC. BioEntry W supports auto MDI/MDIX, therefore a crossover cable is not necessary. ⒸCopyright 2007 Suprema Inc.
BioEntry W Connections RS485 Connection for Host Communication Power IN (Red) Power GND (Black) Signal GND (Black/White Stripe) TRX+ (Blue/White Stripe) TRX- (Yellow/White Stripe) GND TRX+ TRXRS232-485 Converter BioEntry W Power IN (Red) Power GND (Black) Signal GND (Black/White Stripe) TRX+ (Blue/White Stripe) TRX- (Yellow/White Stripe) BioEntry W Notes − Only the devices at the both ends of the bus should be terminated.
BioEntry W Connections RS485 Connection for Secure I/O Power IN (Red) Power GND (Black) Signal GND (Black/ White Stripe) TRX+ (Blue/ White Stripe) TRX- (Yellow/ White Stripe) Power IN (Red) Power GND (Black) Signal GND (Black/White Stripe) TRX+ (Blue/White Stripe) TRX- (Yellow/White Stripe) BioEntry W BioEntry W TRX GND TRX+ TRX- TRX GND TRX+ TRX- Secure I/O Secure I/O Notes − For bus termination, only the devices at both ends of the bus should be terminated.
BioEntry W Connections Relay Connection – Fail safe lock BioEntry W (20) Relay NO (Gray/White Stripe) (19) Relay COM (Green/White Stripe) (18) Relay NC (Orange/White Stripe) + Deadbolt / Door strike DC Power supply ⒸCopyright 2007 Suprema Inc.
BioEntry W Connections Relay Connection – Fail secure lock BioEntry W (20) Relay NO (Gray/White Stripe) (19) Relay COM (Green/White Stripe) (18) Relay NC (Orange/White Stripe) + Deadbolt / Door strike - DC Power supply ⒸCopyright 2007 Suprema Inc.
BioEntry W Connections Relay Connection - Automatic door RTE Switch Presence Detector BioEntry W Automatic Door RTE Switch (20) Relay NO (Gray/White Stripe) (19) Relay COM (Green/White Stripe) (18) Relay NC (Orange/White Stripe) ⒸCopyright 2007 Suprema Inc.
BioEntry W Connections Digital Input Connection (RTE/ Door sensor) BioEntry W (13) (1) (13) (2) Door Status 485 GND (Black/White Stripe) Input 1 (Brown) 485 GND (Black/White Stripe) Input 0 (Purple) Request TO Exit ⒸCopyright 2007 Suprema Inc.
BioEntry W Connections Digital Input Connection (Alarm/ Emergency switch) BioEntry W (13) (1) (13) (2) Switch #1 485 GND (Black/White Stripe) Input 1 (Brown) 485 GND (Black/White Stripe) Input 0 (Purple) Switch #2 ⒸCopyright 2007 Suprema Inc.
BioEntry W Connections Wiegand Input RFID Reader GND Wiegand D1 Wiegand D0 BioEntry W (14) Wiegand GND (White/Black Stripe) (15) Wiegand D1 (White) (16) Wiegand D0 (Green) Wiegand Output Controller GND Wiegand D1 Wiegand D0 BioEntry W (14) Wiegand GND (White/Black Stripe) (15) Wiegand D1 (White) (16) Wiegand D0 (Green) ⒸCopyright 2007 Suprema Inc.
BioEntry W Resetting Network Settings In case of forgetting network setting of the device (TCP/IP or RS-485 setting) during installation or using the device, you can initialize network setting (TCP/IP or RS-485 setting) by using the network reset switch on the back panel of the device. Please refer to the figures as below. 1. Turn on the device. 2. Press and hold the network reset switch until the device turns off. (Then, the device will restart.) Network Default Setting TCP/IP Address : 192.168.0.
BioEntry W Electrical Specifications Min. Typ. Max. Notes Voltage (V) 10.8 12 13.2 Current (mA) - VIH (V) - TBD VIL (V) - TBD Pull-up resistance (Ω) - 4.7k - VOH (V) - 5 - VOL (V) - 0.8 - Pull-up resistance (Ω) - 4.7k - Switching capacity (A) - - 1 0.3 30V DC 125V AC Switching power (resistive) - - 30W 37.5VA DC AC Switching voltage (V) - - 110 125 DC AC Use regulated DC power adaptor only.
BioEntry W Product Specifications Max Users Log Capacity CPU 5000 users (10,000 templates) [1:1 & 1:N] 50,000 logs 533MHz DSP Memory 8MB Flash + 8MB RAM System RF Options Interfaces Input / Output Power General 125KHz HID PROX TCP/IP, RS485, Wiegand 2 TTL Inputs, 1 Relay Output 12VDC, PoE (Power over Ethernet) BioEntry W (W x H x D) 50 x 172 x 44 mm Wall Bracket (W x H) 40 x 157 mm (screw joint included) Dimensions ⒸCopyright 2007 Suprema Inc.
BioEntry W Troubleshooting Please contact your local dealer/distributor for support or contact Suprema at support@supremainc.com. Please submit the following information and we will coordinate support with your local dealer/distributor. Device model F/W version of the device H/W version of the device Detailed information regarding the issue Error messages / screenshots, if possible Contact information (Company, Name, Telephone, Email) ⒸCopyright 2007 Suprema Inc.
BioEntry W Precautions for Device Cleaning Wipe out the device surface with dry towel or cloth. Use a soft dry towel when removing dust or impurities from the surface of the sensor. Cleaning the sensor with a detergent, benzene or thinner will damage the surface and disrupt the unit's ability to properly read a fingerprint. ⒸCopyright 2007 Suprema Inc.
BioEntry W FCC Rules Caution Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user’s authority to operate the equipment. Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interface, and (2) this device must accept any interface received, including interference that may cause undesired operation.