User Manual

ELECTRONIC BALLAST INSTALLATION INSTRUCTION
SUNPARK ELECTRONICS CORP.
Model : 120-2/32 IS
CAUTIONARY NOTES: Do not use this equipment for other than intended use.
1. Verify that the line voltage matches the ballast voltage.
2. Installation to be made by a qualified person in accordance with applicable codes.
Warning
This product may cause interference to radio equipment and should not be
installed near maritime safety communications equipment or other critical
navigation or communication equipment operating between 0.45-30 MHz.
Features
l 120V AC input
l Power factor: > 0.95
l Low harmonics
l Class P
l Sound rating A
l UL, cUL recognized. File E177888
l Indoor / outdoor use.
Lamp type & power consumption :
Lamp Power consumption [Watts]
17wT8 35
25wT8 48
32wT8 60
25wT12 46
34wT12 42
40wT12 49
Before installation
1. Disconnect line voltage before installing or replacing lamp.
2. Ballast case must be grounded.
3. Place the ballast to a stable support and fix it.
Installation
1. Connect the lamps to the ballast according to the label . Ballast supports only the
type of lamps specified on the product label.
2. Connect the AC power line. Connect the black wire to L terminal and white wire
to N terminal of the AC source.
3. Connections of power wires must be fully insulated.