Order Number : GETEC-C1-19-476 FCC Part 15 subpart C Test Report Number : GETEC-E3-19-026 Page 1 / 1 APPENDIX H : USER’S MANUAL EUT Type: Z-Wave Gateway FCC ID.
Table of Contents Congratulations..................................................................................................................................................................................................................................................................1 Features and Benefits......................................................................................................................................................................................................
Congratulations: Thank you for purchasing URC’s TRF-ZW10 Z-Wave Gateway. The TRF-ZW10 communicates with Z-Wave devices and your compatible URC control system, integrating them seamlessly together into a single user interface for control and automation. Incorporating this gateway as part of a URC control system offers a myriad of potential additions to your home. Easily expand your system by adding virtually any Z-Wave enabled device to your connected home.
Features and Benefits Continued: ● Easy Setup Wizard: End-user setup wizard allows for an intuitive setup with a simple Q&A format. Adding devices is easy with pre-configured settings for many of the most popular products available. ● Wi-Fi Enabled (or Hard-line): Wi-Fi connectivity allows for flexible placement in strategic locations of the home/business. ● ZigBee & Bluetooth Support (Limited): The TRF-ZW10 has the ability to communicate with devices using either a ZigBee or Bluetooth protocol.
Device Layout and Connections: 1. USB Port: Provides features and support for advanced applications. 2. Ethernet Port: Connects the gateway physically to the local network via an ethernet cable. 3. 12V Power Receptacle: Connects to the included power adapter.
6. Reset Button: For use only when directed by URC Technical Support. This button is recessed and can be pressed with a paperclip: ● Reset Network Settings: Press the button three (3) times within six (6) seconds. ● Factory Reset: Press the button six (6) times within six (6) seconds. ● Power Cycle (Shutdown): Press-n-hold the button for 30 seconds to shutdown the unit and then disconnect the gateway from its power supply.
LED Indicator Lights: There are seven (7) indicator lights on the TRF-ZW10, below are their potential values: a. Power LED: Three (3) available states: ● LED On: Indicates the device is powered on. ● LED Off: Indicates the device is powered off. ● LED Flashing: Indicates that a firmware update is in progress. b. Internet LED: Three (3) available states: ● LED On: Gateway is connected via Ethernet. ● LED Off: Gateway is not connected via Ethernet. ● LED Flashing: Gateway cannot connect to the Internet. c.
e. Service LED: Provides information on the status of the cloud service. Three (3) available states: ● LED On: Cloud service is connected and working properly ● LED Off: No Cloud service installed ● Flashing: Cloud service is not sending data properly.
Installation: Setup of the TRF-ZW10 and Z-Wave devices is performed by a certified URC integrator. This also includes integration of the Z-Wave system to a compatible URC control system. After the URC integrator has performed the initial configuration, an email is sent to the end-user. This email contains information on your Z-Wave account and system. Follow the email’s instructions on finalizing your account.
Excluding a Device: 1. Press-n-hold the Sync button for three (3) seconds. The Z-Wave light blinks faster, twice every second to indicate that the gateway is in exclusion mode. 2. Follow the pairing/unpairing instructions for the Z-Wave device. 3. When the device has been successfully unpaired, the Z-Wave LED flashes rapidly for less than a second, then returns to the exclusion state. 4. Pressing the Sync button once, returns the gateway to the inclusion state.
Warranty Statement: 1. LIMITED WARRANTY AND DISCLAIMERS RAM : DDR2 256MB Universal Remote Control, Inc.
THIS LIMITED WARRANTY DOES NOT COVER TECHNICAL ASSISTANCE FOR HARDWARE OR SOFTWARE USAGE EXCEPT AS EXPRESSLY PROVIDED FOR HEREIN. The warranty limitations and warranty disclaimers may not apply to end user in whole or in part, where such are restricted or excluded by applicable law, and such shall apply to the maximum extent permitted by applicable law.
batteries). This limited warranty is invalid if the factory applied serial number has been altered or removed from the URC equipment. This limited warranty specifically excludes the URC equipment sold by unauthorized resellers. APPLICABLE LAW AND SUCH SHALL APPLY TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW. URC SHALL NOT BE HELD RESPONSIBLE FOR THE STATEMENTS MADE BY OTHERS.
Federal Communication Commission Interference Statement: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Declaration of Conformity: Company Name : Summit Technology, Inc Company Address : 130, Digital-ro, Namsung Plaza Suite 611, Geumcheon-gu, Seoul, Korea Contact Information : Phone: (+82)-2-6929-3161 Product Name : Z-Wave Gateway Model Name : TRF-ZW10 ● Radio Equipment Directive ■ EN 62368-1 (2014) + A11 (2017) ■ ETSI EN 301 489-17 V3.1.1 (2016) ■ EN 62479 (2010 ■ ETSI EN 300 328 V2.1.1 (2016) ■ ETSI EN 301 489-1 V2.1.1 (2016) ● Test Report No.