SRI Summation Research Inc STR-1800 Land Mobile Data Radio Operations and Maintenance Manual Meeting 21st Century Challenges - with – Technically Appropriate Solutions Prepared by: Summation Research Inc – Melbourne, FL SRI Document Number: 70-STR1800-00 O&M Revision: K This document contains information proprietary and confidential to SRI. Transmittal, receipt, or possession of this document does not express, license, or imply any rights to use, design, or manufacture from this information.
(Intentionally Left Blank)
70-STR1800-00 Rev K STR-1800 O&M Manual SUMMATION RESEARCH, INC. LIMITED WARRANTY Summation Research, Inc. (herein called SRI) warrants that the equipment’s of its manufacture as identified and described within this manual shall, at the time of shipment to the original purchaser, be free from defects in material and workmanship. This warranty applies only to equipment installed, operated, and maintained in accordance with SRI recommendations.
70-STR1800-00 Rev K STR-1800 O&M Manual (Intentionally Left Blank) - ii -
70-STR1800-00 Rev K STR-1800 O&M Manual RF Exposure Statement The radio generates RF electromagnetic energy during transmit mode. This radio is designed for and classified as “Occupational Use Only”, meaning it must be used only during the course of employment by individuals aware of the hazards, and the ways to minimize such hazards. This radio is NOT intended for use by the “General Population” in an uncontrolled environment.
70-STR1800-00 Rev K STR-1800 O&M Manual Déclaration d'exposition aux RF La radio génère de l'énergie électromagnétique RF pendant le mode de transmission. Cette radio est conçue et classée comme «usage professionnel uniquement», ce qui signifie qu'elle ne doit être utilisée que pendant le travail par des personnes conscientes des dangers et des moyens de minimiser ces dangers. Cette radio n'est PAS destinée à être utilisée par la «population générale» dans un environnement non contrôlé.
0-STR1800-00 Rev K STR-1800 O&M Manual Declaration of Conformity and Compliance (STR-1830 Model) Hereby, Summation Research, Inc.
70-STR1800-00 Rev K STR-1800 O&M Manual Icelandic Hér með lýsir Summation Research, Inc. yfir því að STR-1830 PMR er í samræmi við grunnkröfur og aðrar kröfur, sem gerðar eru í tilskipun 2014/53/EC Italian Con la presente Summation Research, Inc. dichiara che questo STR-1830 PMR è conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 2014/53/CE. Ar šo Summation Research, Inc.
70-STR1800-00 Rev K STR-1800 O&M Manual Record of Changes Dates of issue for original and each revision of this document are: REVISION DATE TITLE OR BRIEF DESCRIPTION A A1 B C D E E2 F G H June 2010 September 2010 January 2011 January 2011 February 2011 June 2011 August 2011 September 2011 June 2012 July 2012 I April 2018 J K January 2020 May 2020 Initial Production Release Updated Exposure Statement Limits Updated for active RS485 interface Updated for ETSI Radio Variants Updated for Digital Interf
70-STR1800-00 Rev K STR-1800 O&M Manual (Intentionally Left Blank) - viii -
70-STR1800-00 Rev K STR-1800 O&M Manual Table of Contents SECTION 1 INTRODUCTION ........................................................................................................... 1 1.1 Scope.................................................................................................................................. 1 1.2 Product Description ........................................................................................................... 1 1.3 Technical Specifications ..............
70-STR1800-00 Rev K STR-1800 O&M Manual (Intentionally Left Blank) -x-
70-STR1800-00 Rev K STR-1800 O&M Manual List of Figures Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 STR-1800 Multi-Mode Land Mobile Data Radio ..................................................................... 1 System Overview, Single Receive Channel Models .................................................................. 2 System Overview, Dual Receive Channel Model......................................................................
70-STR1800-00 Rev K STR-1800 O&M Manual (Intentionally Left Blank) - xii -
70-STR1800-00 Rev K STR-1800 O&M Manual SECTION 1 INTRODUCTION The STR-1800 series of UHF radio represents a state-of-the-art communications product line providing multi-mode, half-duplex audio to radio frequency (RF) transmit and receive functions. Consisting of multiple models, the series provides analog FM transceiver functions in the 400 to 470 MHz frequency band (STR-1820, STR-1820A, STR-1821, STR-1821A, and STR-1830) or the 136 to 174 MHz band (STR1840).
70-STR1800-00 Rev K STR-1800 O&M Manual Front Panel Bezel Main Radio Chassis TX Flex Main Radio DB-9 Card System Overview, Single Receive Channel Models Front Panel Bezel Main Radio Chassis Flex Enhanced Modem Card (EMC) DB-9 13.6 VDC RX2 Conn Main Radio Card Figure 3 RF Antenna ÷ RX1 Front Panel Card (FPC) Diag/Prog I/O TXRX Switch TX UHF Conn DB-25 Conn Molex Pwr Conn PTT Tx/Rx Audio 13.
70-STR1800-00 Rev K STR-1800 O&M Manual Operating Power 13.6 VDC 15% (current @ 13.6 V: transmit 9 A, receive 0.7 A) Operator Adjustments None Reliability 25,000 hr MBTF Antenna Connector UHF PL-259 type female located on rear panel Audio Interface and Control Connector DB-25 socket on front panel including 4 channel select lines, audio in/out, pushto-talk. Does not apply to STR-1821 radios. Separate DB-9 socket for diagnostic and programming interface.
70-STR1800-00 Rev K STR-1800 O&M Manual per TIA-603-C Intermodulation 65 dB minimum Dynamic Range With input signals ranging from -100 dBm to 0 dBm, the SINAD at the receiver is 23 dB minimum when receiving a signal modulated with a 1 KHz tone at 60% rated deviation Sensitivity 12 dB SINAD minimum for input signal level of -116 dBm Spurious and Image Rejection 70 dB minimum Transmit to Receive Recovery Time 30 msec maximum measured from removal of keying signal to the transmitter Audio Output A
70-STR1800-00 Rev K STR-1800 O&M Manual SECTION 2 2.1 RECEIVING, INSPECTION AND INSTALLATION Unloading and Unpacking NOTE If shipping carton is damaged upon receipt, request carrier’s agent be present during unpacking and inspection of the system. Upon receipt of the equipment, inspect the shipping container for damage.
70-STR1800-00 Rev K 2.4 STR-1800 O&M Manual Connector Descriptions and Signal Definitions This section describes the types of connectors used on the STR-1800 and provides the definition of the signals associated with each. 2.4.1 Primary Power The Primary Power connector is located on the rear of the STR-1800 series radios and is attached to the unit itself via approximately 6 inches of 14 gage wire. Characteristics of this connector are as indicated in the following table.
70-STR1800-00 Rev K STR-1800 O&M Manual 2.4.3 Audio/Control The Audio/Control connector is located on the front of the STR-1800 series radios and is mounted directly to the front panel mold of the radio. Characteristics of this connector are as indicated in the following table.
70-STR1800-00 Rev K STR-1800 O&M Manual Pins not listed within this table are all defined as no connects. For the channel select lines described above, the following table defines the control functions of these inputs.
70-STR1800-00 Rev K Pin STR-1800 O&M Manual Signal DESCRIPTION AND CHARACTERISTICS 1 RD (Input) Data input to radio. RS-232 electrical levels. 2 Conn Key A stubbed (i.e.; filled) pin location which prevents users from connecting a standard UART DB-9 cable into the radio. 3 TD (Output) Data output from radio. RS-232 electrical levels. 4 RFPDO Remote front panel data output. TTL electrical levels. 5 GND Ground 6 USBD+ Universal serial data bus positive. USB electrical levels.
70-STR1800-00 Rev K STR-1800 O&M Manual (Intentionally Left Blank) - 10 -
70-STR1800-00 Rev K STR-1800 O&M Manual SECTION 3 OPERATION Operation of the STR-1800 series radios is accomplished by utilizing a special software program to configure the radio for the proper configuration and then connecting the system into the target platform for audio data transmission and reception. The following sections describe the STR-1800 series radio operations from the perspective of configuring the unit for the proper radio channel characteristics prior to final system installation. 3.
70-STR1800-00 Rev K STR-1800 O&M Manual Factory users are allowed to control radio settings pertaining to output power level calibration. The following figure depicts this expanded configuration. SRI Assembly # 30-STR1800-01 Factory Programming Cable Remote Front Panel DB-9 Front Panel Connector Serial Port 13.
70-STR1800-00 Rev K STR-1800 O&M Manual Figure 6 Field Control Software Initial Screen The Factory version requires cabling as noted in Figure 5. Running the Factory (“GE Personnel”) version of the application provides a user interface screen as shown in Figure 7 below. The capability is similar to the above mode however additional functionality will require the Figure 5 cabling.
70-STR1800-00 Rev K STR-1800 O&M Manual If this is the first time either program is being utilized or if the operator has changed the PC’s serial communications port being utilized, the first action taken by the user should be to establish the correct port selection. This can be accomplished by doing a menu selection from the “Radio Comm Port” selection. After this action, the user may select “Get All”.
70-STR1800-00 Rev K STR-1800 O&M Manual 2) On initial power up or on any change of the frequency select lines into the radio, the target frequency setting may take up to 100 msec to obtain. 3) If push-to-talk is active at any time during the tuning period outlined in note 2 above, the tuning action will not complete until push-to-talk is removed and stay’s in a non-active condition for a period of 2 seconds.
70-STR1800-00 Rev K STR-1800 O&M Manual (Intentionally Left Blank) - 16 -
70-STR1800-00 Rev K STR-1800 O&M Manual SECTION 4 MAINTENANCE In order to ensure that the STR-1800 system is always ready for operation, it should be checked periodically so that potential defects may be discovered and corrected before they develop into any serious damage or system failure. A minimal preventive maintenance program will significantly increase the systems life span.
70-STR1800-00 Rev K STR-1800 O&M Manual (Intentionally Left Blank) - 18 -
70-STR1800-00 Rev K STR-1800 O&M Manual APPENDIX A DECLARATION OF CONFORMITY
70-STR1800-00 Rev K STR-1800 O&M Manual (Intentionally Left Blank)
70-STR1800-00 Rev K STR-1800 O&M Manual
70-STR1800-00 Rev K STR-1800 O&M Manual (Intentionally Left Blank)
70-STR1800-00 Rev K STR-1800 O&M Manual (Intentionally Left Blank)
70-STR1800-00 Rev K STR-1800 O&M Manual (Intentionally Left Blank)
70-STR1800-00 Rev K STR-1800 O&M Manual
70-STR1800-00 Rev K STR-1800 O&M Manual (Intentionally Left Blank)
70-STR1800-00 Rev K STR-1800 O&M Manual (Intentionally Left Blank)
SRI Summation Research Inc Summation Research, Inc Is • A QUALIFIED SMALL BUSINESS VENDOR • LOCATED ON THE HIGH TECHNOLOGY SPACE COAST OF FLORIDA • DEDICATED TO PROVIDING ON-TIME AND APPROPRIATE SOLUTIONS TO THE CHALLENGES OUR CUSTOMERS PRESENT • FOUNDED ON THE FIRM BELIEVE THAT SMALL COMPANIES CAN EFFICIENTLY PROVIDE RAPID RESPONSE, LOWER COST SOLUTIONS TO LARGER COMMERCIAL CORPORATIONS OR GOVERNMENT AGENCIES.