User manual for SWR-A001 1 Sumitomo Electric Industries, Ltd.
CONTENT FCC Notice ............................................................................................................................................... 2 1.Introduction............................................................................................................................................. 3 2.Specification ........................................................................................................................................... 4 3.Installation method .........
1.Introduction 60GHz Radar SWR-A001 is installed on the roadside and detects pedestrians based on reflected radio waves. The radar communicates with the data acquisition equipment via Ethernet and outputs detection results every 100ms. The Radar RF Unit Processing and Interface Unit Data Acquisition Equipment Ethernet Figurer 1. System configuration Table1.Detection performance No ITEM DESCRIPTION 1 Detection Area Max. 60m x 30m 2 Installation Height 3.
2.Specification Table 2 shows general specifications. Table2. General specifications No ITEM DESCRIPTION 1 Power Supply DC12V 2 Power Consumption Less than 10W 3 Temperature -40 to +75°C 4 Humidity 25 to 98% 5 Waterproofing IP67 6 Dimensions H:120mm x W:130mm x D:36mm 7 Weight Less than 2kg 8 Radar Frequency 61.0 to 61.5GHz 9 Interfaces Ethernet 100BASE-T 4 Sumitomo Electric Industries, Ltd.
3.Installation method 3.1 Installation requirement To ensure the best performance of the radar, it should be installed at a height between 3.5m and 5m. Also, since it is difficult to detect the area directly below the radar, it should be installed 3m behind the pedestrian crossing. Figure 2. Installation requirement 5 Sumitomo Electric Industries, Ltd.
3.2 Horizontal adjustment Adjust the horizontal angle so that the radar is facing the middle of the crosswalk on the other side. Aim for the middle of the crosswalk on the other side. Figure 3. Horizontal adjustment 3.3 Vertical adjustment Attach the radar to horizontal arm using the mounting bracket. Adjust the elevation angle according to the detection area using an angle meter or similar device. The radar will be installed to the horizontal arm via a wire and a bracket.
4. Equipment Connection The Radar has a RJ-45(jack) connector and supports passive PoE. Use CAT 5e cables. The Radar starts up when the power supply is connected. Table 3. RJ-45 connector pin assignments Pin No. FUNCTION 1 Ethernet TX+ 2 Ethernet TX- 3 Ethernet RX+ 4 DC+12V 5 DC+12V 6 Ethernet RX- 7 0V 8 0V 7 Sumitomo Electric Industries, Ltd.
5.Tool Operation Procedure (1)Start the detection result drawing tool “AreaConfigCreator.exe”. (2)Once the tool is activated, click “Receive Start” at the lower left of the screen. Click “Receive Start” Figure 5. Detection result drawing tool (3)When data is received, the detection result is displayed on the screen. Figure 6. The results of detection 8 Sumitomo Electric Industries, Ltd.