T AF D R SYNK® 4K Wireless System Transmitter: 0240031065 Receiver: 0240031075
T AF R D
Contents Warnings and Cautions ........................................................................... 1 Warnings .....................................................................................................................1 Cautions ......................................................................................................................2 Product Description ................................................................................ 4 Intended Use ..............................
Electromagnetic Compatibility........................................................................ 28 D R AF T Symbol Definitions ................................................................................
Warnings and Cautions In this manual, the terms and definitions below apply. • Warning: Possible injury to the patient or user. • Caution: Possible damage to the equipment. • Note: More information to clarify the instructions. Warnings To avoid potential serious injury to the user and the patient and/or damage to this device, please note the following warnings. Read this manual thoroughly and know its contents prior to using the device. 2.
13. 14. 15. 16. 17. 18. 19. R 20. T 12. AF 11. to potential problems with secure connections or electromagnetic compatibility. Use the provided HDMI high speed cable (or other Strykerapproved HDMI cable) with the SYNK® 4K Wireless System. Only connect items that have been specified as part of the SYNK® 4K Wireless System or that have been specified as being compatible with the system. To avoid the risk of electric shock, this equipment must only be connected to a supply mains with protective earth.
6. 7. 8. 9. 10. 11. 12. 13. T 5. To ensure electromagnetic compatibility, refer to the “Electromagnetic Compatibility” section of this manual. The devices must be installed and operated according to the EMC information provided in this manual. Do not position the devices so that it is difficult to disconnect the power cords from the supply mains. Connect the devices to a hospital grade receptacle to achieve grounding reliability.
Product Description The SYNK® 4K Wireless System wirelessly transfers video data from a transmitter to up to two linked receivers. The transmitter provides an HDMI input that supports 1080p and 4K video formats, and the receiver provides an HDMI output supporting the same formats. Once the devices are linked, the transmitter wirelessly transfers high-definition video to the receiver for output on a secondary display.
SYNK® 4K Wireless Transmitter Package Contents T (1) SYNK® 4K Wireless Transmitter (0240031065) (1) Hospital-grade power cord (0105033001) (1) HDMI high speed cable, 2M (P39077) (2) Remote cables (0105206758) (1) Power supply (P27315) (2) Temporary tokens (blue) (0105208884) AF • • • • • • R SYNK® 4K Wireless Receiver D Package Contents • • • • • (1) Receiver (0240031075) (1) Hospital-grade power cord (0105033001) (1) Power supply (P27315) (2) Shoulder bolts (P44094) (1) Y cable (P43614) • (1) HD
System Features This section outlines the features of the SYNK® 4K Wireless Transmitter and Receiver. SYNK® 4K Wireless Transmitter Front Panel 1 2 3 4 T 5 Powers transmitter ON and OFF. 2. Power Indicator Steady Green - Power is ON 3. Token Status Indicator Blinking White - Waiting for normal token Green - Ready for pairing or Wireless link is established Amber - Warning, see Troubleshooting Red - Error, contact service representative R AF 1. Power switch (hard) D 4. Token Slot 5.
SYNK® 4K Wireless Transmitter Rear Panel 1 2 3 4 5 6 7 Maintenance port (Stryker use only) 2. Remote 1 Connects to video source remote output 1 3. Remote 2 Connects to video source remote output 2 AF T 1. HUB Port 4. Micro USB Port Maintenance port (Stryker use only) 5. HDMI Out Connects to a primary display 6. HDMI In Connects to a digital input source AC Power Inlet Connects to AC power adapter D R 7.
SYNK® 4K Wireless Receiver Front Panel 1 2 3 4 5 Powers receiver ON and OFF 2. Power Indicator Steady Green - Power is ON 3. Token Status Indicator Blinking White - Waiting for normal token Blinking Green - Attempting to pair Green - Wireless link is established Amber - Warning, see Troubleshooting Red - Error, contact service representative 4. Token Slot Token insertion site used to establish a wireless connection 5.
SYNK® 4K Wireless Receiver Rear Panel 1 2 3 4 5 6 Maintenance port (Stryker use only) 2. Remote 1 Connects to Connected OR Hub Remote 1 3. Remote 2 Connects to Connected OR Hub Remote 2 AF T 1. HUB Port Maintenance port (Stryker use only) 5. HDMI Out Connects to a primary display. 6. AC Power Inlet Connects to AC power adapter D R 4.
Setup AF T • When the SYNK® 4K Wireless System is interconnected with other electrical devices, leakage currents may be additive, resulting in electromagnetic emissions that can interfere with the normal function of electronic medical equipment. To properly control electromagnetic emissions and avoid potential harm to the patient or user, ensure all electrical devices are installed and interconnected according to the requirements of IEC 60601-1.
T Mounting the Receiver on a Display AF The receiver can be mounted on the back of a 32” 4K Surgical Display (0240031050), on a roll stand or cart. Power off and unplug the receiver and display from the electrical outlets before mounting. Insert the provided shoulder bolts into the back of the display. D R 1. 2. 3. Ensure the shoulder bolts are secured before proceeding.
Push the receiver forward, then rotate it clockwise until you feel it lock firmly into place. D R AF 4. T on the display.
Connecting Power from the AC Adapter The transmitter must be powered by the AC adapter provided in its packaging. The receiver may be powered by the AC adapter provided in its packaging or by using the provided Y-cable to draw power from the 32” 4K surgical display. To power the receiver from the display, see the next section. Follow these instructions to connect power to the transmitter and receiver from the AC power adapter. 1. 2.
Generic Video Source Direct to Display Refer to the following instructions and wiring diagram for a typical wireless configuration. Display HDMI 2. D 5. 14 Receiver Using the provided HDMI cable, connect the HDMI OUT on the video source to the HDMI IN on the transmitter. • The HDMI OUT on the transmitter can be connected to the HDMI IN on a secondary display. Using the provided HDMI cable, connect the HDMI OUT on the receiver to the HDMI IN on the primary display.
Generic Remote Port Routing Refer to the following instructions and wiring diagram for a wireless configuration where the camera control unit is located separately from the Connected OR Hub. Note: Obtain a second set of remote cables from another Stryker visualization system before proceeding. Connected OR HUB Display Remote Cables 1. HDMI Receiver HDMI Using the provided HDMI cable, connect the HDMI OUT on the camera control unit to the HDMI IN on the transmitter.
Wireless Configuration The SYNK® 4K Wireless System uses a radio-frequency (RF) link to deliver high-definition video signals in real time. Each system uses a portion of the RF spectrum commonly referred to as a “channel” to broadcast its signal. The list of allowed channels is regulated and varies by region. The SYNK® 4K Wireless System uses 40 MHz channels in the 5.170-5.850 GHz spectrum. The 5.170-5.850 GHz spectrum is also used by 802.11a/n/ac devices as well as 5.8 GHz cordless phones.
Operation Pairing is the act of creating a wireless link between a transmitter and a receiver. A token is used to create the link, by inserting it into the token slot of the transmitter to write discrete pairing data and then inserting the token into the token slot of the receiver to read the pairing data. A transmitter can pair with up to two (2) receivers. The same token may be used to create each pair, or a different token may be used for each pair.
on. Keep transmitter/receiver sets that are in permanent link mode in the same operating room. Removing a Permanent Link To return a receiver and transmitter to the default linking mode: 3. 4. AF 5. 6. 7. Turn on the devices. Insert the temporary token into the transmitter and remove when the token LED turns green. Power cycle the transmitter. Insert the token into the receiver and remove the token when the token LED turns green. Power cycle the receiver after removing the token.
Troubleshooting Before returning your receiver or transmitter for service, consult the troubleshooting list below: Current Status Remedy No video Power LED off Make sure that the power cord is properly connected to the device. Power LED on Make sure the HDMI video cables are connected to the Transmitter and Receiver. Token LED pulsing white Insert the token to link Transmitter and Receiver. Make sure the device is well ventilated and air vents are not blocked.
Cycle the power switch on the device. Ensure that the Receiver is within 10 meters of the Transmitter. Re-insert token into Receiver.
Cleaning The SYNK® 4K Transmitter and Receiver are not intended to come into contact with the patient or to be used in the sterile field. The devices may be cleaned and disinfected, but not sterilized. Follow the instructions below. The temporary token or permanent token may also be cleaned and disinfected, if soiled. Follow the instructions below.
Materials and Equipment The user shall provide all materials and equipment required to clean and disinfect the SYNK® 4K Transmitter, SYNK® 4K Receiver, and tokens. Item Description Cleaning and Disinfection Wear protective equipment as required by the medical facility Germicidal disposal wipes (or germicidal spray and sterile cloth) To clean exterior of devices D R AF T Gloves, eye protection, etc.
Maintenance Follow the instructions in this section for proper care of the devices. Note: Repairs and equipment modifications shall be performed only by Stryker-authorized personnel. Stryker Endoscopy assumes no product liability or warranty responsibility for devices repaired by or purchased from thirdparty service organizations. Inspecting the Transmitter and Receiver T Inspect the transmitter and receiver regularly for cleanliness.
be expected to be reused and/or reprocessed before it may require repair. In addition, the device’s service life is largely determined by wear, reprocessing methods, and any damage resulting from use. To extend the time between device servicing, always follow the care and handling instructions in this user manual. Before each use, test the device functionality and inspect it for any sign of damage per the Inspection section.
Technical Specifications SYNK® 4K Transmitter Input: One High-Definition Multimedia Interface (HDMI) Connector Output: One High-Definition Multimedia Interface (HDMI) Connector Video Formats 1080p: 1920 x 1080 @ 60 fps 4K: 3840 x 2160 @ 60 fps Weight 1.4 lbs (0.6 kg) Total Shipping Weight 3.8 lbs (1.7 kg) Dimensions 7.7” W x 7.2” D x 1.8” H (19.6 cm W x 18.3 cm D x 4.
Channel Bandwidth 40 MHz Channel Allocation Automatic frequency selection with Wi-Fi avoidance Encoding Orthogonal Frequency Division Multiplexing with AES 128-bit encryption Antenna 5x4 MIMO Electrical Power Supply Input: 100 – 240 V ~ 50-60 Hz 1.1 A AC/DC Adapter Manufacturer: XP Power / Bridge Power Model: AFM30US12 / BPM150S24F11 12V 2.5A / 24V 2.
Classification and Approvals R AF T Class I Medical Equipment Medical equipment with respect to electric shock, fire, and mechanical hazards only in accordance with IEC 60601-1 and CAN/CSA C22.2 No.
Electromagnetic Compatibility All electrical medical equipment requires special precautions to ensure electromagnetic compatibility with other electrical medical devices. To ensure electromagnetic compatibility (EMC), the devices must be installed and operated according to the EMC information provided in this manual. AF T Note: • The devices have been designed and tested to comply with IEC 60601-1-2 requirements for EMC with other devices.
Guidance and Manufacturer’s Declaration: Electromagnetic Immunity The devices are intended for use in the electromagnetic environment specified below. The customer or user of the devices should ensure that they are used in such an environment. Immunity Test IEC 60601 Test Level Compliance Level Electromagnetic Environment: Guidance Electrostatic Discharge (ESD) ±8kV contact ±8kV contact ±15kV air ±15kV air Floors should be wood, concrete, or ceramic tile.
Guidance and Manufacturer’s Declaration: Electromagnetic Immunity The devices are intended for use in the electromagnetic environment specified below. The customer or user of the devices should ensure that they are used in such an environment.
Tested Specifications for Immunity to RF Wireless Communications Equipment Test frequency (MHz) Band (MHz) Service Modulation Maximum Power (W) Distance (m) Immunity Test Level (V/m) 385 380–390 TETRA 400 Pulse modulation 18 Hz 1.8 0.3 27 450 430–470 GMRS 460, FRS 460 FM ± 5 kHz deviation 1 kHz sine 2.0 0.3 28 710 704–787 LTE Band 13, 17 Pulse modulation 217 Hz 0.2 0.3 9 800–960 GSM 800/900, TETRA 800, iDEN 820, CDMA 850, LTE Band 5 Pulse modulation 18 Hz 2.0 0.
Symbol Definitions The devices and labeling contain symbols that provide important information for the safe and proper use of the devices. These symbols are defined below. Device/Package Labeling Consult instructions for use Date of manufacture Product catalog number AF Product serial number T Legal manufacturer Quantity Made in USA R Denotes compliance to CAN/CSA C22.
33 T AF R D
34 T AF R D
T AF R D
T AF R D Stryker Endoscopy 5900 Optical Court San Jose, CA 95138 USA 1-800-624-4422 U.S. Patents: www.stryker.com/patents Stryker Corporation or its divisions or other corporate affiliated entities own, use or have applied for the following trademarks or service marks: CrossFlow, Formula, and the Stryker logo. All other trademarks are trademarks of their respective owners or holders.