IMPORTANT INFORMATION: File this in your TPS records Total Performance System Consoles 5100-1 Console REF 5100-50 Irrigation Console REF Hermes READY™ 5100-201 Console REF 5100-250 Irrigation Console REF User's Guide •••••••••••••••••••••• Includes setup, safety, repair, and warranty information for the Stryker Total Performance System. For answers to questions about other equipment, see the information supplied with that equipment. Version 4.
Contents Software License Notice .................................................................................... 3 Where to Find Answers ...................................................................................... 4 Warning, Caution, Note Defined ........................................................................ 4 Important Safety Instructions ............................................................................ 5 System Overview Symbol Definition ................................
Where to Find Answers When you have questions about your Stryker TPS products, there are several places to find the answers. In this book Use this book to set up your system and select console options. This book also contains information on system safety, repair, and component warranty. ............................................................................................................................................
IMPORTANT SAFETY INSTRUCTIONS WARNING: The personal safety of the patient and/or user may be involved. Disregarding this information could result in injury to the patient and/or operating room staff. Read and understand the following warnings. SYSTEM SAFETY ! DO NOT modify ground of power cord. ! Burs and blades are intended for single use only. ! Equipment not suitable for use in the presence of flammable anesthetic mixture with air or with oxygen or nitrous oxide.
System Overview The Stryker Total Performance System is intended for use in the cutting, drilling, decorticating, and smoothing of bone and other bone related tissue in a variety of surgical procedures. It is also used for the placement or cutting of screws, wires, pins, and other fixation devices as it can be used to cut metal. TPS console powers multiple handpieces while allowing the user to program a number of customized settings.
Operating Instructions WARNINGS: ! Before using this system read and understand the information in this manual and the instructions supplied with each TPS component and Stryker Endoscopy handpieces. Pay close attention to the User/Patient Safety Information. ! Familiarization with the Total Performance System prior to use is important. If you have any questions, contact your Stryker Instruments representative or Stryker Customer Service at 1-800-253-3210.
The Control Screen TPS Start-Up Screen This display appears on the screen every time the console is turned on. This display remains on the screen until a cord is plugged into one of the TPS handpiece ports or the OPT button is depressed. If a handpiece cord is plugged into a handpiece port when the console is turned on, this display shows momentarily before changing to either a no handpiece detected screen or to the screen of the selected handpiece.
Functions of the Control Screen The TPS console allows the user to select functions and settings such as handpiece selection, speed, and direction. Designed to be easy to use and understand, the touch sensitive control screen allows you to set the system controls with the touch of a finger. Interactive icons on the control panel represent system components and functions. The control screen also provides important monitoring information for the selected handpiece.
Select Your System Settings Standard Features NOTE: When the console is turned on, its default setting is factory default unless a Surgeon Preference setting is selected as the start up default. See Surgeon Preference for further details. Main Option Icon The option icon appears on all handpiece screens and allows access to the MAIN OPTION screen. See MAIN OPTION SCREEN for further details. 1.
Quick Reference Guide Icon Definition Handpiece Select This type of icon appears when a cord (without a handpiece) is plugged into the corresponding Endo, TPS1 or TPS2 port. Footswitch Icon: Appears when a footswitch is connected to the console. Also gives access to footswitch adjustments screen. It appears depressed when selected.
Saw Handpiece Screen TPS Oscillating and Sagittal Saws POWER/WATER ADJUSTMENT The power icon functions as a toggle switch for power and water settings. Power and irrigation adjustments are made using the adjustment arrows. As the power setting is reduced from 100%, a vertical bar displays to correspond to the lower selected maximum power. This screen appears when a TPS saw is selected at the TPS1 port with the maximum power set at 100%.
Rotary Handpiece Screen SPEED/WATER ADJUSTMENT The speed icon functions as a toggle switch for speed and water settings. Speed and irrigation adjustments are made using the adjustment arrows. DIRECTION OPTIONS FORWARD Clockwise REVERSE Counterclockwise This screen appears when a TPS rotary handpiece is selected. The TPS Universal Drill is plugged into the TPS2 port and the speed is set at 75,000 RPM. ENDO, TPS1 and the footswitch icons indicate that other instruments are plugged into the console.
The Stryker Endoscopy and Leibinger Handpiece Screen Depress the mode icon and set the maximum speed using the adjustment arrows. Speed settings are individually selected for each mode. Default speed settings and incremental steps are specific to each handpiece. MODES Operation in high speed mode. Operation in oscillate mode. The oscillate mode is selected and Set Speed is set at 1,800 RPM. Operation in low speed mode.
Main Option Screen Select the OPT icon to access the MAIN OPTION screen. This screen allows direct access to the handpieces attached to the console, console and user settings, and system information. OPTION 1, 2, and E icons appear only when handpieces are plugged into the corresponding console ports. A handpiece must be plugged in to program its settings. To go to the HANDPIECE ADJUSTMENT screen, touch the option button that corresponds to the desired handpiece. Refer to HANDPIECE ADJUSTMENT.
System Information Screen Selecting the INFO icon from the MAIN OPTION menu displays the part numbers and revision levels of the configured system components. This information is used as a diagnostic aid only. Return to the MAIN OPTION screen.
Handpiece Adjustment Screen Select a Handpiece Option icon from the MAIN OPTION screen to access this screen. ATTACHMENT: Use the arrow icon on the left to scroll through the list of attachments. Select the attachment that is assembled to the handpiece by stopping on it. NOTE: For quick access to this screen, touch the handpiece title displayed at the top of any handpiece screen. And return to the handpiece screen by touching the handpiece title displayed on this screen.
Console Adjustment Screen Select the CONSOLE ADJUSTMENTS icon from the MAIN OPTION screen to access this screen. Select CONTRAST, BRIGHTNESS or VOLUME then press the arrow icons to change the setting. Contrast: Screen contrast lightens at higher settings. The chosen setting remains until reset. Brightness: Screen brightness intensifies at higher settings. Volume: The audible signal is louder at higher settings. Use the BIG SCREEN toggle button to select one of the following options.
Footswitch Adjustment Screen This screen appears only when using a TPS Footswitch that is Revision 3 or newer. See Standard Features. NOTE: The Footswitch revision is displayed on the SYSTEM INFORMATION screen. Access this screen by selecting the Footswitch icon on the HANDPIECE CONTROL SCREEN or HANDPIECE ADJUSTMENTS screen. NOTE: These footswitch settings function only for the handpiece for which they were selected. The handpiece is identified at the top of the screen.
Footswitch Button Mapping Screen Access this screen by selecting the ADVANCED icon on the FOOTSWITCH ADJUSTMENTS screen. The default functions of each footswitch pedal and button can be reprogrammed to accommodate the surgeon's preferences. Depending on the type of handpiece displayed at the top of the screen, one or more of the following options will be available on this screen. The DIRECTION, OP MODE, and RUN MODE icons correspond respectively to the two largest footswitch pedals.
Handpiece Button Mapping Screen Access this screen from the Handpiece Adjustment screen. Use it to change handpiece button functions. Depending on the features of the handpiece, as many as five buttons can be reprogrammed. Identify corresponding button numbers by pressing the buttons on the handpiece. When the handpiece button is selected, the corresponding function is displayed on the screen. Use the arrow icons to scroll through the function options. Stop on the desired option.
Surgeon Preference Screen Access the SURGEON PREFERENCE screen from the MAIN OPTIONS screen. The console is able to capture and store the preferred settings of different surgeon's. There are three options: • Factory default settings • Settings saved by a previous surgeon • Collection and storage of new settings Using factory settings 1. Use the arrows to obtain "Stryker" and "Factory Default." NOTE: The EDIT, DELETE and padlock icons do not function while factory default settings are selected.
Messages Message If you select OK to this question: Delete all the surgeon's procedures? The surgeon ID and all procedures will be deleted. Change the name of all the surgeon's procedures? Procedures listed under the surgeon will be moved under the current surgeon's name. Identical record found. Maximum number of records exceeded. Please delete inactive records. Initializing console hardware. Please wait. Handpiece has reached recommended service interval.
Specifications Models: 5100-1 TPS Console 5100-50 TPS Irrigation Console Size: Class I 11.8 in. [299 mm] width 7.0 in. [179 mm] height 9.0 in. [229 mm] depth 12.2 in. [310 mm] depth (units with irrigation pump) Weight: 9 lbs. [4.1 Kg] 14.1 lbs. [6.4 Kg] (units with irrigation pump) Models: 5100-201 TPS Hermes READY™ Console 5100-250 TPS Hermes READY™ Irrigation Console PORT TYPE Endo B TPS1 BF TPS2 BF SYMBOL IPX0 Ordinary Equipment Protective Earth Ground Size: 11.8 in. [299 mm] width 7.
Repair and Loaner Program This service is available in the United States only. Outside the U.S.A., contact your Stryker sales representative or your nearest subsidiary listed on the last page. On request, Stryker Instruments will provide a loaner unit for your use while repairs are being made. Please clean and sterilize all potentially contaminated products being sent in for repair, credit, or return of a loaner unit.
Stryker International Subsidiaries Stryker SA European Headquarters Cite-Centre, Grand-Rue 92 CH-1820 Montreux, Switzerland Stryker BV Postbus 8747 5605 LS Eindhoven The Netherlands Stryker Corp.- U.K.Branch Medway House 5000 Newbury Business Park London Road, Newbury Berkshire, U.K. RG14 2ST Stryker Deutschland GmbH Gewerbeallee 18 D-45478 Mulheim an der Ruhr Germany Stryker Polska Sp. Zo.o ul. Kolejowa 10/21 01-217 Warsawa, Poland Stryker Far East Inc.
4100 E.