Faregate Manual Contract No.: METRORAIL FAREGATES FQ18152 Faregate Manual Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 1/136 .
Faregate Manual LIST OF CHANGES Rev. 0 CHANGES First version Rev. 10-26-2020 0 10-26-2020 YS Song STraffic DATE Quality Manager KH Kim 10-26-2020 KW Jung 10-26-2020 Eric Cho 10-26-2020 Project Manager Date ENTITY NAME Manager APPROVAL AUTHOR TITLE Tech. Solution VALIDATION DATE Date Rev. SIGN SIGN Entity : STraffic Document No. : WMF-FGT-F-xxx 2/136 .
Faregate Manual LIST OF CONTENTS 1. Introduction ............................................................................................................. 9 1.1. Purpose .................................................................................................................. 9 1.2. Scope ...................................................................................................................... 9 1.3. Abbreviations .............................................................
Faregate Manual Address: Suite 125 1593 Springhill Rd, Vienna, VA 22182 ............................... 32 Contact: Brian Hong (H.P: 703-732-7153) .......................................................... 32 Web Site: http://www.straffic.co.kr/en/index.php/company ............................. 32 4. Faregate Connection ............................................................................................ 33 4.1. Interconnect Cable.......................................................
Faregate Manual 5.18. Data management – Transaction – Autoload page ........................................... 55 5.19. Data management – Audit register page ........................................................... 56 5.20. Data management – History page ...................................................................... 57 5.21. Data management – History – User access page.............................................. 58 5.22. Data management – History – User access page...................
Faregate Manual 8.2.2. Software Interface............................................................................................ 81 9. Clamshell Barrier .................................................................................................. 82 9.1. Safety and Convenience ..................................................................................... 82 9.2. Description Diagram ............................................................................................ 83 9.3.
Faregate Manual 10.2.1. 10.3. Indicator Light .................................................................................................... 104 10.3.1. 10.4. Specification .................................................................................................. 104 Customer Display .............................................................................................. 105 10.4.1. 10.5. Specification ............................................................................
Faregate Manual 12.2.1. Specification .................................................................................................. 124 12.2.2. Switch On the UPS ........................................................................................ 125 12.2.3. Status Indicators and Alarms ....................................................................... 126 12.2.4. UPS Battery .................................................................................................... 127 12.3.
Faregate Manual 1. Introduction 1.1. Purpose The purpose of this document is to introduce the information for the configuration of faregate and faregate operation. 1.2. Scope This document covers generally the physical specification, appearance, configuration and operation manual. 1.3.
Faregate Manual MTBF Mean Time Between Failure NWS Network Switch OS Operating System OSD On Screen Display PPT Payment Processing Target PSU Power Supply Unit SMPS Switching Mode Power Supply SSD Solid State Drive ST Station Terminal TBD To Be Determined USB Universal Serial Bus UPS Uninterruptible Power Supply VGA Video Graphics Array WMATA Washington Metropolitan Area Transit Authority [Table 1] Date Rev. 10-26-2020 0 Date Rev.
Faregate Manual 2. Overview 2.1. General Description The faregate is installed between the free area and the paid area. It enables passengers to pass through the passage between the free area and the paid area with the ticket. The ADA faregate is designed suitable for the use of visually impaired passengers or those with impaired mobility and PPT is positioned in a manner that is ergonomically appropriate for users in wheelchairs.
Faregate Manual 2.2. Configuration of Faregate The drawing below shows the dimension of standard and ADA faregate. 2.2.1. Outline Layout [Figure 2] [Figure 3] Date Rev. 10-26-2020 0 Date Outline layout of the stadard faregate Outline layout of the ADA faregate Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 12/136 .
Faregate Manual 2.2.2. Internal Layout The figure below shows the internal modular components and layout. [Figure 4] Date Rev. 10-26-2020 0 Date Rev. Faregate Modular components Entity : STraffic Document No. : WMF-FGT-F-xxx 13/136 .
Faregate Manual 2.3. Faregate type definition The faregate consists of the ADA aisle and the standard aisle. Faregate cabinets that make up the aisle are classified into ADA end, ADA reversible, standard end and standard reversible types. 2.3.1. Standard Faregate Standard end cabinets are divided into master and slave. The master cabinet includes the major modules such as ECU, GCU, PSU, UPS and NWS but the slave cabinet does not include the major modules.
Faregate Manual 2.3.2. ADA Faregate ADA end cabinets are divided into master and slave. The master cabinet includes the major modules such as ECU, GCU, PSU, UPS and NWS but the slave cabinet does not include the major modules. ADA reversible cabinets are divided into two types, one type is located between ADA aisles as shown in [Figure 8] and the other type is located between ADA aisle and standard aisle as shown in [Figure 9]. [Figure 6] [Figure 7] Date Rev.
Faregate Manual 2.4. Faregate nomenclature 2.4.1. Faregate nomenclature for different types Faregate cabinets are identified by 4 alphanumeric codes (XXXX) as follows The definition of barrier position (digit 3, 4) is as below [Figure 8] Code definitions according to barrier position View direction is from the free area to the paid area. The numeric code is the position of a standard barrier and the alphabet code is the position of a wide barrier.
Faregate Manual 2.4.2. 2.4.3. The rules of Faregate layout • Viewing cabinets from free area to paid area • Placement of cabinet from right side • Base cabinets place at rightmost (SB10, WBa0) Faregate type and typical array layout [Figure 9] Date Rev. 10-26-2020 0 Date Typical array layout of faregate Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 17/136 .
Faregate Manual 2.4.4. Definition of detailed faregate type The main components of each type are shown in the following table.
Faregate Manual Type: Standard Reversible ECU : 1 GCU : 1 UPS : 1 PSU : 1 NWS: 1 PPT : 2 SR13 Customer Display : 2 Status Display : 2 Indicator Light : 2 Emergency Light : 2 Directional Sensor (Rx) : 18 Directional Sensor (Tx) : 18 Standard Barrier (Right type) : 2 Type: Standard Reversible ECU : 1 GCU : 1 UPS : 1 PSU : 1 NWS: 1 PPT : 2 SR24 Customer Display : 2 Status Display : 2 Indicator Light : 2 Emergency Light : 2 Directional Sensor (Rx) : 18 Directional Sensor (Tx) : 18 Standard Barrier (Left type
Faregate Manual Type: Standard End (Left End) – Slave PPT : 1 Customer Display : 1 Status Display : 1 SE03 Indicator Light : 1 Emergency Light : 1 Directional Sensor (Rx) : 0 Directional Sensor (Tx) : 18 Standard Barrier (Right type) : 1 Type: Standard End (Left End) – Slave PPT : 1 Customer Display : 1 Status Display : 1 SE04 Indicator Light : 1 Emergency Light : 1 Directional Sensor (Rx) : 0 Directional Sensor (Tx) : 18 Standard Barrier (Left type) : 1 Date Rev. 10-26-2020 0 Date Rev.
Faregate Manual Type: ADA Base (Right End) – Master ECU : 1 GCU : 1 UPS : 1 PSU : 1 NWS: 1 PPT : 3 WBa0 Customer Display : 1 Status Display : 1 Indicator Light : 1 Emergency Light : 1 Directional Sensor (Rx) : 18 Directional Sensor (Tx) : 0 ADA Barrier (Right type) : 1 Type: ADA Base (Right End) – Master ECU : 1 GCU : 1 UPS : 1 PSU : 1 NWS: 1 PPT : 3 WBb0 Customer Display : 1 Status Display : 1 Indicator Light : 1 Emergency Light : 1 Directional Sensor (Rx) : 18 Directional Sensor (Tx) : 0 ADA Barrier (Le
Faregate Manual Type: ADA Reversible ECU : 1 GCU : 1 UPS : 1 PSU : 1 NWS: 1 PPT : 6 WRac Customer Display : 2 Status Display : 2 Indicator Light : 2 Emergency Light : 2 Directional Sensor (Rx) : 18 Directional Sensor (Tx) : 18 ADA Barrier (Right type) : 2 Type: ADA Reversible ECU : 1 GCU : 1 UPS : 1 PSU : 1 NWS: 1 PPT : 6 WRbd Customer Display : 2 Status Display : 2 Indicator Light : 2 Emergency Light : 2 Directional Sensor (Rx) : 18 Directional Sensor (Tx) : 18 ADA Barrier (Left type) : 2 Date Rev.
Faregate Manual Type: ADA End (Left End) – Slave PPT : 3 Customer Display : 1 Status Display : 1 WE0c Indicator Light : 1 Emergency Light : 1 Directional Sensor (Rx) : 0 Directional Sensor (Tx) : 18 ADA Barrier (Right type) : 1 Type: ADA End (Left End) – Slave PPT : 3 Customer Display : 1 Status Display : 1 WE0d Indicator Light : 1 Emergency Light : 1 Directional Sensor (Rx) : 0 Directional Sensor (Tx) : 18 ADA Barrier (Left type) : 1 Date Rev. 10-26-2020 0 Date Rev.
Faregate Manual Type: Hybrid Reversible ECU : 1 GCU : 1 UPS : 1 PSU : 1 NWS: 1 PPT : 4 HRa3 Customer Display : 2 Status Display : 2 Indicator Light : 2 Emergency Light : 2 Directional Sensor (Rx) : 18 Directional Sensor (Tx) : 18 Standard Barrier (Right type) : 1 ADA Barrier (Right type) : 1 Type: Hybrid Reversible ECU : 1 GCU : 1 UPS : 1 PSU : 1 NWS: 1 PPT : 4 HRb4 Customer Display : 2 Status Display : 2 Indicator Light : 2 Emergency Light : 2 Directional Sensor (Rx) : 18 Directional Sensor (Tx) : 18 St
Faregate Manual Type: Hybrid Reversible ECU : 1 GCU : 1 UPS : 1 PSU : 1 NWS: 1 PPT : 4 HR1c Customer Display : 2 Status Display : 2 Indicator Light : 2 Emergency Light : 2 Directional Sensor (Rx) : 18 Directional Sensor (Tx) : 18 Standard Barrier (Right type) : 1 ADA Barrier (Right type) : 1 Type: Hybrid Reversible ECU : 1 GCU : 1 UPS : 1 PSU : 1 NWS: 1 PPT : 4 HR2d Customer Display : 2 Status Display : 2 Indicator Light : 2 Emergency Light : 2 Directional Sensor (Rx) : 18 Directional Sensor (Tx) : 18 St
Faregate Manual 2.5. System Configuration 2.5.1. Hardware Logical Architecture [Figure 10] ADA Faregate Logical Architecture The faregate consists of master / slave side for passenger service. The major modules such as ECU, GCU, UPS, and NWS are equipped on master side and these modules control all components including slave side. ※ The only difference between Standard faregate and ADA faregate is the quantity of the PPT. Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No.
Faregate Manual 2.5.2. General specification The general specification of the faregate is as follows: Item Specification Dimension (D x W x H) - Standard : 70.87 x 11.02 x 39.37 inches - ADA : 70.87 x 11.81 x 39.37 inches Enclosure - Stainless steel : 2.0mm / 316L - Finish : brushed No.4 Base Cabinet - Stainless steel : 3.0mm / 316L - Finish : brushed No.4 End Cover - Material : PC - Thickness : 4.
Faregate Manual LED Backlit Resolution : 640 x 480 Interface : DVI, VGA MTBF : 50000 hours Entry : Green Status Display Do not enter : Red Indicator Light 3-Color LED (Red, Green, Yellow) Infra-Red beam (Emitter, Receiver) Directional Sensor Quantity : 18 Sets 18W Amplifier Board Audio 20W, 4ohm Speaker Emergency light power - 120VAC / 12VDC (24W) Emergency Light Emergency light - 1.
Faregate Manual 3. Faregate Label 3.1. Nameplate The faregate nameplate will be placed in the faregate. The user can check the product name and model number on this label with opening the maintenance door with key. [Figure 11] Date Rev. 10-26-2020 0 Date Nameplate and FCC instruction label position Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 29/136 .
Faregate Manual The nameplate will be divided two types. Because the AC input is only for the master faregate not slave faregate. [Figure 12] [Figure 13] Date Rev. 10-26-2020 0 Date Nameplate for the Master faregate Nameplate for the Slave faregate Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 30/136 .
Faregate Manual 3.2. FCC Compliance label and instructions The faregate will have the instruction label for FCC compliance. The upper label is for the slave cabinet and the bottom label is for the master cabinet. [Figure 14] Label for FCC compliance Caution: changes or modifications not expressly approved by Straffic America could void your authority to operate the equipment.
Faregate Manual 3.3. Risk of Fire [Figure 15] 3.4. Label for Risk of Fire Contact Information Responsible Party: STraffic America, LLC Address: Suite 125 1593 Springhill Rd, Vienna, VA 22182 Contact: Brian Hong (H.P: 703-732-7153) Web Site: http://www.straffic.co.kr/en/index.php/company Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 32/136 .
Faregate Manual 4. 4.1. Faregate Connection Interconnect Cable The faregate aisle consists of 2 types, master and slave. Between the master and slave cabinet, the interconnection cable should be connected. The below figure is a simple diagram between the master and slave cabinet. The emergency FA cable is connected to EMG TB (Emergency Terminal Block) in master cabinet based on the aisle. To power on the faregate, turn the ELCB switch on then, turn the UPS on, and then turn the power supply on.
Faregate Manual 1. DVI Cable Connect the DVI cable with the DVI extension cable in the secondary cabinet. 2. LAN Cable 3. Digital Signal Cable Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 34/136 .
Faregate Manual Connect the digital signal cable to the SLB(Secondary Link Board) CN X1/X2. 4. DC Power Cable Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 35/136 .
Faregate Manual Connect the DC Power Cable to SLB CN 1. [Figure 17] 4.2. Faregate Interconnect Cable Power Connection 4.2.1.1. Power Plug Both the main and emergency power will utilize a twist lock plug. This lock will prevent the power cables from disconnecting, reducing the risk of faulty power cable connections. The twist lock power plug also provides a safety environment for the maintenance operator in the future.
Faregate Manual [Figure 19] 4.3. Current Power Receptacle Example Data Connection Cable One WMATA approved Ethernet switch per faregate aisle will be installed in the faregate. The switch will connect all TR4s associated with a single aisle as well as the faregate controller to the WMATA LAN/WAN. The Wan will be utilized to connect the central system level and station level while the LAN will be used to connect equipment in the station level.
Faregate Manual 5. Operation Manual 5.1. Maintenance menu log-in page Insert ID/PW in each textbox to login maintenance menu. (ID: afceng / PW: afc1004) After login, you can go to prev menu with ‘ [ ‘ key and go to home menu with ‘ ] ’ key. Note. The faregate application limits the use of some key-in such as “arrow ←↑→↓” keys. Please use the mouse-pad on the keyboard. Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 38/136 .
Faregate Manual 5.2. Top level Maintenance menu. This page is top level maintenance menu. 1. Mode Setting – You can change Faregate Operation mode and Faregate Aisle mode in this menu. 2. Module Test – You can test Faregate barrier, Each PPT, Faregate Passenger sensor/Door switch, Faregate Indicator light/Status display and Faregate speaker in this menu. 3.
Faregate Manual 5.3. Mode setting page You can choose a menu for Faregate operation mode, Aisle mode on this page. Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 40/136 .
Faregate Manual 5.4. Mode setting – Operation mode page You can choose a button for in service mode, out of service mode and emergency mode on this page. (After getting out of the maintenance menu, the faregate operation mode will be applied.) Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 41/136 .
Faregate Manual 5.5. Mode setting – Aisle mode page You can choose a button for entry mode, exit mode and bi-directional mode on this page. (After getting out of the maintenance menu, the faregate aisle mode will be applied.) Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 42/136 .
Faregate Manual 5.6. Module Test page You can choose menu for barrier test, PPT test, sensor test, LED test, sound test on this page. Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 43/136 .
Faregate Manual 5.7. Module test – Barrier test page You can open or close the faregate barrier by clicking the “OPEN” and “CLOSE” button. And the faregate barrier can open and close automatically with the “AUTO” button. Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 44/136 .
Faregate Manual 5.8. Module test – PPT test page You can test the PPT on this page. After clicking each button of the PPT to be tested, when the "Tap Test Card" comment appears, you can perform the PPT test by tagging the test card. (Upper screen is status after click PPT 1 button.) Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 45/136 .
Faregate Manual 5.9. Module test – Sensor test page You can choose the test for passenger sensor or door switch on this page. Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 46/136 .
Faregate Manual 5.10. Module test – Sensor test – Passenger sensor test page You can test the passenger sensor on this page. By going through the aisle or by covering the passenger sensor on this faregate. Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 47/136 .
Faregate Manual 5.11. Module test – Sensor test – Door switch You can test the Door switch on this page. Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 48/136 .
Faregate Manual 5.12. Module test – LED test page. You can test by clicking checkbox and “SET” button on this page. (After you click checkbox, click “SET” button for Indicator light/Status display test on this page. And you can test Indicator light/status display automatically with the “AUTO” button.) Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 49/136 .
Faregate Manual 5.13. Module test – Sound test page You can test for faregate sound on this page. (Input a value in the textbox for testing the faregate sound. Next, click the “SET” button and the “TEST” button for testing.) Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 50/136 .
Faregate Manual 5.14. Data management page You can choose menu for checking transaction data, audit register, history data and Faregate parameter/software version on this page. Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 51/136 .
Faregate Manual 5.15. Data management – Transaction page You can choose a menu for checking transaction entry, exit, and autoload data on this page. Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 52/136 .
Faregate Manual 5.16. Data management – Transaction – Entry page You can check transaction entry data on this page. Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 53/136 .
Faregate Manual 5.17. Data management – Transaction – Exit page You can check transaction exit data on this page. Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 54/136 .
Faregate Manual 5.18. Data management – Transaction – Autoload page You can check transaction autoload data on this page. Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 55/136 .
Faregate Manual 5.19. Data management – Audit register page You can check Audit register data on this page. Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 56/136 .
Faregate Manual 5.20. Data management – History page You can choose a menu for checking user access/event history data on this page. Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 57/136 .
Faregate Manual 5.21. Data management – History – User access page You can check user access history data on this page. Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 58/136 .
Faregate Manual 5.22. Data management – History – User access page You can check event history data on this page. Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 59/136 .
Faregate Manual 5.23. Data management – Version check page You can choose a menu for checking parameter/software version on this page. Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 60/136 .
Faregate Manual 5.24. Data management – Version check – Parameter page You can check parameter version on this page. Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 61/136 .
Faregate Manual 5.25. Data management – Version check – Software page You can check software version on this page. Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 62/136 .
Faregate Manual 5.26. Configuration page You can choose a configuration menu for device information, device configuration communication setting and component ID on this page. Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 63/136 .
Faregate Manual 5.27. Configuration – Device information page You can set the faregate information on this page. Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 64/136 .
Faregate Manual 5.28. Configuration – Device information page You can set the faregate configuration value on this page. Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 65/136 .
Faregate Manual 5.29. Configuration – Device information page You can set the target IP address to be connected on this page. Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 66/136 .
Faregate Manual 5.30. Configuration – Device information page You can set the faregate component ID on this page. Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 67/136 .
Faregate Manual 5.31. Reset page You can choose a menu for GCU reset, PPT reset, faregate data reset, faregate close and faregate shutdown on this page. Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 68/136 .
Faregate Manual 5.32. Reset – GCU Reset page You can reset GCU on this page. Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 69/136 .
Faregate Manual 5.33. Reset – PPT Reset page You can reset all PPT on this page. Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 70/136 .
Faregate Manual 5.34. Reset – Faregate data Reset page You can reset all of faregate data on this page. (Transaction data, Audit register data and History data will be reset.) Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 71/136 .
Faregate Manual 5.35. Reset – Faregate close page You can close faregate main application on this page. Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 72/136 .
Faregate Manual 5.36. Reset – Faregate shutdown page You can shutdown the faregate ECU on this page. Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 73/136 .
Faregate Manual 6. Module Configuration The configuration of faregate is as follows; • Electronic Control Unit (ECU) • Gate Control Unit (GCU) • Barrier (Standard, ADA type) • Customer Display • Status Display • Indicator Light • Emergency Light • Directional Sensors • Payment Processing Target (PPT) • Network Switch (NWS) • Audible Tones • PSU • UPS • Master / Slave Link Board • ES / RS Link Board • Maintenance Keypad • Interior Light Date Rev.
Faregate Manual 7. Electronic Control Unit (ECU) The Electronic Control Unit (ECU) controls all the sub-modules and processes all the data in the faregate. The ECU uses industrial standard single board computer for its reliability. An ECU is installed in each faregate aisle and controls only faregate aisle where it is installed. Therefore, the failure of ECU in any faregate aisle will not affect the other faregate aisles and their control. [Figure 20] 7.1.
Faregate Manual Embedded Gen 4 + GFX Core Shared system memory up to 256MB SDRAM Graphics 1 x VGA, 1 x DVI Single channel max : 2048 x 1536 @ 60Hz Dual channel max : 1920 x 1080 @ 60Hz Ethernet 2 x 10/100/1000M RJ45 port 1 x 2.5” SDD : 128 GB (SQF-S25M4-128G-SBE) Partition Storage C : OS (64GB) D : Data Backup (32GB) E : Application (32GB) USB 5 x USB2.0, 1 x USB3.
Faregate Manual 7.2. Dimension Diagram [Figure 21] Date Rev. 10-26-2020 0 Date Rev. Dimension of ECU Entity : STraffic Document No. : WMF-FGT-F-xxx 77/136 .
Faregate Manual 8. Gate Control Unit (GCU) Almost of components such as clamshell barrier, directional sensor, status display, indicator light and etc. are connected to the Gate Control Unit (GCU) through digital input/output. These components are controlled by the GCU through the ECU commands. The GCU is connected to the ECU through RS-232 interface physically.
Faregate Manual [Figure 22] Date Rev. 10-26-2020 0 Date Rev. GCU Board Entity : STraffic Document No. : WMF-FGT-F-xxx 79/136 .
Faregate Manual 8.1. Specification Item Model No / Vendor Specification 242000-20 / STraffic 32 bit Processor Processor Internal clock – 44.
Faregate Manual 8.2. Interface with ECU 8.2.1. Hardware Interface GCU is connected to ECU through the RS-232 interface physically. The below is an interface connection diagram between and GCU. [Figure 23] 8.2.2. Communitaction between ECU and GCU Software Interface All of the components are connected to GCU through digital input/output such as Clamshell Barrier, Directional Sensor, Status Display, Indicator Light, Switches and so on.
Faregate Manual 9. Clamshell Barrier The clamshell barrier utilizes bi-parting retractable panel doors. The clamshell barrier is being operated by barrier control board which is getting command signal from the GCU. Command signal consists of open and close command, and it is decided to operate and stop as sensing of internal two magnetic sensors. The clamshell barrier uses DC motor and worm-gear. It makes easy access to control, softer movement and quiet, therefore, it is efficient to admission control.
Faregate Manual 9.2. Description Diagram The clamshell barrier uses a PWM DC motor for quiet and smooth operation, an encoder and sensors use to detect the rotational speed of the motor. The clamshell barrier follows the two motion control signals of the GCU such as opening and closing with the I/O interface. The “OPEN” and “CLOSE” commands from the GCU are used to control the clamshell barrier.
Faregate Manual 9.3. Components of barrier [Figure 26] Components of standard barrier [Figure 27] Date Rev. 10-26-2020 0 Date Rev. Components of ADA barrier Entity : STraffic Document No. : WMF-FGT-F-xxx 84/136 .
Faregate Manual 9.4. Standard barrier 9.4.1. Appearance [Figure 28] Date Rev. 10-26-2020 0 Date Rev. Standard Barrier Entity : STraffic Document No. : WMF-FGT-F-xxx 85/136 .
Faregate Manual 9.4.2. Layout – Right type The motor location is on the right inside the faregate enclosure [Figure 29] Date Rev. 10-26-2020 0 Date Rev. Standard Barrier – Right type Entity : STraffic Document No. : WMF-FGT-F-xxx 86/136 .
Faregate Manual 9.4.3. Layout – Left type The motor location is on the left inside the faregate enclosure [Figure 30] Date Rev. 10-26-2020 0 Date Rev. Standard Barrier – Left type Entity : STraffic Document No. : WMF-FGT-F-xxx 87/136 .
Faregate Manual 9.4.4. Gap between the standard barrier 2.0 ± 0.2 inch [50.8 ± 5.1 mm] indicates the gap between standard barriers when it is closed. Passage width between faregate cabinets is 22 inch [558.5 mm] The closed barriers withstand a force at 300 lbs. (Moving at 3 mph and striking the barrier at the point where both panels meet.) [Figure 31] Date Rev. 10-26-2020 0 Date The gap between the standard barriers Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 88/136 .
Faregate Manual 9.4.5. Standard barrier layout and type in the cabinet The standard barrier layout in the cabinet is as follows. [Figure 32] Standard barrier layout and type in the cabinet The barrier type can be easily identified by the following procedure. 1) Look at the barrier in the aisle like arrow ①. 2) Check the flapper is on the right or left side of the center of the cabinet 3) If the flapper is on the right side, the barrier is right type; otherwise left type. Date Rev.
Faregate Manual 9.5. ADA barrier 9.5.1. Appearance [Figure 33] Date Rev. 10-26-2020 0 Date Rev. ADA Barrier Entity : STraffic Document No. : WMF-FGT-F-xxx 90/136 .
Faregate Manual 9.5.2. Layout – Right type The motor location is on the right inside the ADA faregate enclosure [Figure 34] Date Rev. 10-26-2020 0 Date Rev. ADA Barrier – Right type Entity : STraffic Document No. : WMF-FGT-F-xxx 91/136 .
Faregate Manual 9.5.3. Layout – Left type The location is on the left inside the ADA faregate enclosure [Figure 35] Date Rev. 10-26-2020 0 Date Rev. ADA Barrier – Left type Entity : STraffic Document No. : WMF-FGT-F-xxx 92/136 .
Faregate Manual 9.5.4. Gap between the ADA barrier 2.0 ± 0.2 inch [50.8 ± 5.1 mm] indicates the gap between ADA barriers when it is closed. Passage width between faregate cabinets is 36 inch [914.4 mm] [Figure 36] Date Rev. 10-26-2020 0 Date The gap between the ADA barriers Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 93/136 .
Faregate Manual 9.5.5. ADA barrier layout and type in the cabinet The ADA barrier layout in the cabinet is as follows. [Figure 37] ADA barrier layout and type in the cabinet The barrier type can be easily identified by the following procedure. 1) Look at the barrier in the aisle like arrow ①. 2) Check the flapper is on the right or left side of the center of the cabinet 3) If the flapper is on the right side, the barrier is right type; otherwise left type. Date Rev. 10-26-2020 0 Date Rev.
Faregate Manual 9.6.
Faregate Manual 9.7. Specification of Motor [Figure 38] Barrier Motor Item Specification Model No / Vendor S9D40-48M(OG54) / SPG Type Permanent magnetic DC motor (Brush type) Model Size ф90 mm Rated Voltage +48VDC Operating Voltage +38.4VDC ~ +57.6VDC Direction of Rotation CW / CCW Operating Position Horizontal Insulation Level Class A Rated Torque 3.88 kgf.cm / 0.384 N.m Rated Current 0.88 ± 20% (A) Rated Revolution 1000 ± 10% (rpm) Rated Output 40W Durability Min.
Faregate Manual 9.7.1. Brush replacement The motor has two brushes on the front and back as shown below. [Figure 39] DC Motor brush The motor brush replacement procedure is as follows. [Figure 40] Brush Replacement 1) Open the protective cap using a flat head screwdriver. 2) Remove the brush in the motor. 3) Replace with a new brush, then assemble in reverse order. ※ The brush does not need to be replaced due to wear over the life of the motor.
Faregate Manual 9.8. Control Board of Clamshell Barrier 9.8.1. Appearance The figure below shows the clamshell barrier control board. [Figure 41] 9.8.2.
Faregate Manual Motor Drive Power +48VDC Control Board Power +24VDC Dimension (W x D) 160 x 90mm [Table 7] 9.8.3. Barrier control board specification Functional Description : DIP Switch The control board of standard clamshell barrier and ADA clamshell barrier is the same. The type (Standard / ADA) of clamshell barrier is identified by the configuration of DIP switch #3. The DIP switch configuration of clamshell barrier is as follows.
Faregate Manual 3) DIP Switch #3 (Barrier type selection) Status Description ON ADA clamshell barrier operating mode OFF Standard clamshell barrier operating mode 4) DIP Switch #4 (Factory setting) Status Description ON Initialization of the EEPROM with the initial factory settings. OFF Normal status Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 100/136 .
Faregate Manual 10. Customer Interface The faregate has fixed graphics, emergency lights, indicator lights, customer displays, and status displays. These customer interfaces are designed and strategically placed to maximize their effectiveness and coincide with ergonomics of fare payment. [Figure 43] Customer Interfaces 10.1. Fixed Graphics The figure below is a fixed graphics concept design with braille that guides customers to the location and correct use of PPT.
Faregate Manual The fixed graphics concept design is attached in front of the ADA faregate to guide customers. [Figure 45] Fixed graphic for ADA Faregate 10.2. Status Display The status display provides information identifying the status of the gate and adjacent aisle to the left. The status display could be “Usage OK” with a symbol of green arrow and “Usage Prohibited” with a symbol of the red circle. The status display is mounted on the vertical panels at both ends of the faregate.
Faregate Manual 10.2.1. Specification Item Specification Model No / Vendor DIR-LED04 / Shanghai Huaming Display status Enter (green arrow), Do not enter (red circle) Status display mode Static display LED colors Green, Red Dimension (W x H) 150mm x 150mm View angle Horizontal: 120 degrees / Vertical: 100 degrees Operating voltage 24VDC ± 10% Power dissipation 6.8watt / green, 6.8watt / red [Table 8] Date Rev. 10-26-2020 0 Date Rev.
Faregate Manual 10.3. Indicator Light For fare processing, faregates are equipped with LED indicator lights that can display various colors with Red, Green and Blue LED combinations. If the processed smart media is valid, either the blue, the yellow or green colors are activated according to the class of fare media presented. And if the media is not valid, the red LED turns on.
Faregate Manual 10.4. Customer Display The customer display is installed on the top of each faregate in each direction of passage and provides information to a customer regarding faregate readiness, faregate aisle usability, transaction success or failure, and fare media status. The customer display brightness could be adjusted automatically based on ambient light conditions. The illuminance sensor is located nearby customer display so the LCD brightness could be adjusted automatically.
Faregate Manual 10.4.1. Specification Item Specification Model No / Vendor LC-OF06588 / Anrecson Elec. Screen Diagonal 6.5 inches Active Area (mm) 132.48(H) x 99.36(V) Pixels H x V 640 x 3(RGB) x 480 Pixel Pitch (mm) 0.207 x 0.
Faregate Manual 10.5. Emergency Light The faregate provides emergency lighting that is powered from the emergency power source (AC 120V) to illuminate the faregate aisle. The emergency power to the faregates is connected in a daisy-chain manner to each faregate from a single source (Station UPS Power). [Figure 50] Emergency Light Emergency lights keep aisle lighting on through the emergency power (Station UPS Power) and the AC/DC power supply. Date Rev. 10-26-2020 0 Date Rev.
Faregate Manual The emergency light connection diagram is as follows. [Figure 51] Connection diagram of Emergency lights 10.5.1. Specification 10.5.1.1. Emergency light power supply Item Specification Model No / Vendor HDR-30-12 / MEAN WELL Input Voltage AC85 ~ 264V / 47 ~ 63Hz Input Current 0.
Faregate Manual 10.5.1.2. Emergency light Item Specification Model No / Vendor EMG-LED01 / Shanghai Huaming Voltage 12VDC Power 120mA @12VDC Operating Temperature - 20 ~ +60℃ Color White MTBF 50,000 hours Dimension (W x D) 56 x 56mm [Table 12] Specification of emergency light 10.6. Audible Tone The faregate provides a unique tone for audio feedback to the customer by the audio amplifier board and speakers.
Faregate Manual [Figure 52] Audible tone of the faregate At a minimum, generated tones will be clearly audible and distinguishable at a distance of not less than thirty (30) feet in an unenclosed environment. [Figure 53] A distance of audible tones 10.6.1. Specification Module Item Specification Model No / Vendor AMP-V3.0 / Shanghai Huaming Rated Voltage +12VDC Audio Amplifier Current Max. 1A Board Output Power Max.
Faregate Manual Rated Power / Impedance 20W / 4Ω Frequency response 350Hz ~ 5800Hz Operating Temperature -40 ~ +70℃ [Table 13] Specification of audio tone components 10.7. Directional Sensors The faregate has 18 sets of sensors in each aisle to detect and determine the movement of all authorized and unauthorized customers between the unpaid and paid areas. When any improper entries are detected, an audible and visual alarm is generated.
Faregate Manual [Figure 55] Paired sensors The photocells are positioned in such a way that they can distinguish between the passage of one or more passengers. [Figure 56] Date Rev. 10-26-2020 0 Date Directional sensor and circuit diagram Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 112/136 .
Faregate Manual 10.7.1. Specification Item Specification Emitter : KPS-CTV S Model No / Vendor Receiver : KPS-CTVN S Vendor : KUN HUNG Elec. Sensing method Through-beam type Operating Voltage 12VDC ~ 24VDC (Ripple max 10%) Current consumption Max : 25mA (Emitter : Max 10mA, Receiver : Max 15mA) Sensing distance ≤1.
Faregate Manual 11. Peripheral Interface 11.1. Servicing Display and Keypad The faregate provides maintenance functionality to perform maintenance at the faregate using the customer display and the USB keypad. This feature allows maintenance staff to remain standing while doing some maintenance activities. When the maintenance or other authorized personnel open the maintenance door, the faregate changes mode to maintenance. [Figure 57] Maintenance Keyboard 11.1.1.
Faregate Manual 11.2. Push Button The push button is located on inside of the faregate enclosure, away from the public and accessible by maintenance personnel when the faregate door is opened. This push button simulates an acceptable fare transaction and cycles the faregate one time. The push button is connected to the GCU and when the push button is activated the barriers are opened and closed in the normal mode of operation.
Faregate Manual 11.3. Door Switch The faregate is equipped with several magnetic switches for detecting the opening and closing of maintenance doors.
Faregate Manual The magnetic switch specification is as follows: Item Description Model No / Vendor AMS-39 / AMSECO Contact Type N.O (Normal Open) without magnet engaged Contact Rating 10VA Operating Gap 3/4 inch min. Color Ivory Operating Temperature 32℉ ~ 120℉ (0℃ ~ 49 ℃) [Table 16] Date Rev. 10-26-2020 0 Date Rev. Specification of Magnetic switch Entity : STraffic Document No. : WMF-FGT-F-xxx 117/136 .
Faregate Manual 11.4. Interior Light The faregate has a portable interior light inside the faregate enclosure to facilitate maintenance and repair. [Figure 61] Interior light Item Description Model No / Vendor HL-LA0203B / Yuan Mei Elec. Lamp Type Super Bright LED Operating Voltage +24VDC Power Dissipation 2W @ 24VDC Lumens 120 lm Dimension (W x L x H) 255 x 59 x 40mm Cable length 3.8m spring cable [Table 17] Date Rev. 10-26-2020 0 Date Rev.
Faregate Manual 11.5. Master Lind Board (MLB) / Slave Link Board (SLB) MLB, SLB is the connection board between the master side and the slave side of the faregate. Most parts of slave side connect to power, communication, and I/O signals through MLB and SLB. [Figure 62] MLB (left) and SLB (Right) 11.6. RS / ES Link Board 11.6.1. RS(Receive Sensor) Link Board The RS Link Board is connected between the GCU and the receiving sensor to send signals from the sensor to the GCU.
Faregate Manual 11.6.2. ES (Emit Sensor) Link Board The ES Link Board is connected between the SLB and the emission sensors to power the sensors. 2 number of ES Link Boards are equipped at slave side. ES Link Board has the provision to connect up to 10 sensors. [Figure 64] Date Rev. 10-26-2020 0 Date Rev. ES Link Board Entity : STraffic Document No. : WMF-FGT-F-xxx 120/136 .
Faregate Manual 12. Power System 12.1. AC Box The faregate has two terminals in the AC box, one for use to connect to the main power and the second connection to emergency power. The main terminal provides AC 120V to PSU via UPS to supply stable power to the submodules and supplies power to the heater. The second emergency terminal supplies power to turn on the emergency light always. [Figure 65] Date Rev. 10-26-2020 0 Date Rev. AC Box Entity : STraffic Document No. : WMF-FGT-F-xxx 121/136 .
Faregate Manual 12.1.1. GFCI (Ground Fault Circuit Interrupter) The GFCI circuit breaker assures protection to people and installations against fault current to earth. The GFCI protect circuits by sensing when a ground fault or earth leakage is greater than 30mA and automatically open the circuit. [Figure 66] GFCI circuit breaker 12.1.1.1.
Faregate Manual Operating Temperature - 25 – 55 °C Maximum Operating Voltage UL/CSA 277 V AC Short-Circuit Current Rating (SCCR) 0.03 mA [Table 18] Date Rev. 10-26-2020 0 Date Rev. RCCB Specification Entity : STraffic Document No. : WMF-FGT-F-xxx 123/136 .
Faregate Manual 12.2. UPS When the ECU receives a power fail signal from the GCU via the UPS due to a loss of main power, all in-process transactions are completed, and barriers are opened by ECU command and then the graceful shutdown proceeds. Upon restoration of power, the faregate returns to its normal operating state without manual intervention. (When the battery is fully discharged, it needs UPS to switch on manually.) [Figure 67] UPS 12.2.1.
Faregate Manual Typical Recharge Time 8 hours 6 total NEMA 5-15R: Output Connections - 3 battery & surge - 3 surge only Input power 120V, 50 or 60 Hz +/- 3Hz Input Conn. 6 ft cord with right angle plug (NEMA 5-15P) Dimension (H x W x D) 6.5” x 3.6” x 11.2” Weight / Color 13.8 lbs / Black Certification / Approvals FCC Part 15 Class B, FCC Part 68, UL1778, Industry Canada [Table 19] UPS Specification 12.2.2. Switch On the UPS Press the push-button on the front panel of the UPS.
Faregate Manual • When Self-Test has successfully completed, only green On Line indicator will be lit. • If the internal battery is not connected, the green On Line indicator and red Replace Battery indicator will light. The UPS will also emit a chirping sound 12.2.3.
Faregate Manual • Replace Battery (red) – is lit whenever the battery is near the end of its useful life, or if the battery is not connected (see above). A battery that is near the end of its useful life has insufficient run-time and should be replaced. Chirps for 1 Minute Every 5 Hours – this alarm is sounded whenever the battery has failed the automatic diagnostic test. 12.2.4. UPS Battery The battery specification of the UPS are as follows.
Faregate Manual Dimension (H x W x D) 3.7 x 2.52 x 5.94 inch Weight 5.5lbs. Standard Warranty 1 year repair or replace RoHS Compliant REACH REACH: Contains SVHCs [Table 20] Battery Specification ※ Battery replacement: In AFC systems, the battery is typically replaced every two years. ※ Battery life may vary depending on the installation environment, usage environment, and so on. Date Rev. 10-26-2020 0 Date Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 128/136 .
Faregate Manual 12.3. Power Supply Unit (PSU) The PSU operates from the AC120V power source of the UPS and supplies 5VDC, 12VDC and 24VDC to each module through the fuse panel. The AC input cable to PSU is fixed using a cable tie on cable mount to prevent disconnection. [Figure 71] [Figure 72] Date Rev. 10-26-2020 0 Date Power Supply Unit Tied cable to prevent disconnection Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 129/136 .
Faregate Manual 12.3.1. Specification 12.3.1.1. Specification of Main PSU Item Description Model No / Vendor G1323 / Gospell Digital Technology Input Rated Voltage 100 ~ 240VAC Frequency 47 ~ 63Hz (Typical 50/60Hz) Efficiency 85% Total Output Power 312W +5.3VSB ± 5% Max. 3A Output Voltage & +5.3V ± 5% Max. 7A Current +12.5V ± 5% Max. 7A +24.5V ± 5% Max. 7A +5.3VSB ≤ 80mVpp +5.3V ≤ 80mVpp +12.5V ≤ 120mVpp +24.5V ≤ 240mVpp +5.3V ≤ 6.5V +12.5V ≤ 14.5V +24.
Faregate Manual 12.3.1.2. Power Supply of Clamshell barrier The following is the power supply required for the motor operation of the clamshell barrier. It supplies power to two barriers installed in one aisle. [Figure 73] Power Supply of Clasmshell barrier Item Description Model No / Vendor CP E SNT 250W / Weidmueller DC Output Voltage +48VDC Max. DC Output Current 5.2 A Max.
Faregate Manual Input – Output, Input – F.G, Output – F.G : 25℃, 70%RH, Insulation Resistance 500VDC, 100MΩ [Table 22] Date Rev. 10-26-2020 0 Date Rev. Specification of barrier power supply Entity : STraffic Document No. : WMF-FGT-F-xxx 132/136 .
Faregate Manual 12.4. Heater The heater and thermostat are installed inside so that the faregate can operate at low temperatures. The heater fan can be replaced without replacing the heating element. [Figure 74] Item Heater Description Model No / Vendor BSAFH01.1.A120.310 / Shanghai Huaming Heating element High performance cartridge Temperature safety cut-out To protect against overheating in case of fan failure Heater body Die-cast aluminum Connection 3-pole screw connector 2.
Faregate Manual 12.5. Thermostat The thermostat is used to turn the heater on and off. The heater turns on when the set temperature is lower than the ambient temperature and turns off when high.
Faregate Manual 13. Network Switch The master cabinet in each aisle is equipped with a gigabit Ethernet switch, which connects all PPTs associated with an aisle as well as the faregate ECU to the WMATA LAN / WAN. The PPTs and ECU associated with an aisle are connected to this switch via CAT6 cables.
Faregate Manual 14. PPT (Payment Processing Target) The PPT connects to the WMATA LAN / WAN via a network switch mounted in the cabinet. And PPT power (24VDC) is supplied to the power board by the main PSU via MLB/SLB. [Figure 77] PPT The network and power connection diagram is shown below. [Figure 78] Date Rev. 10-26-2020 0 Date PPT network and power connection Rev. Entity : STraffic Document No. : WMF-FGT-F-xxx 136/136 .