Ballast 120v 50/60 Hz Ballast 230v 50/60Hz BIO 1.5 PWP 10-0518A 10-0514A Installation, t ll ti O Operation ti & M Maintenance Read and Follow All Safety Instructions. Save These Instructions. SINCE 1963 Manufacturers / Engineers / Sales / Service Germicidal Ultraviolet - Equipment & Lamps 0DUFXV %RXOHYDUG +DXSSDXJH 1< )D[ H PDLO LQIR#XOWUDYLROHW FRP Extensive Product Information Available at: ultraviolet.com Owner’s Manual Models 1 Document No.
TABLE OF CONTENTS SAFETY WARNINGS .......................................................................................................................................................................3 SAFETY INSTRUCTIONS ..............................................................................................................................................................3 SAFETY LABELING .................................................................................................................
SAFETY WARNINGS • All personnel should be alerted to the potential hazards indicated by the product safety labeling on this unit. • The following conventions are used to indicate and classify precautions in this manual and on product safety labeling. Failure to observe precautions could result in injury to people or damage to property. This is the safety alert symbol. It is used to alert you to potential personal injury hazards.
PRODUCT APPLICATION CONSTRUCTION • All filtration and disinfection components, of the Bio-Logic® Pure Water PackTM, are conveniently mounted on a single, stainless steel, mounting bracket. • The system is designed to mount on a vertical surface, a secure (stud or concrete) wall or a cabinet wall, by the systemmounting bracket. • The faucet, supplied with the system, is a low lead, stainless steel faucet, with a hand operated, spring closed lever.
Pure Water PackTM INSTALLATION LOCATION 1. The Pure Water PackTM is designed for “under the sink” installation. The system should be mounted vertically, to a secure wall or cabinet wall, which provides enough room to perform routine maintenance.
SADDLE VALVE INSTALLATION SAFETY EQUIPMENT REQUIRED TO PERFORM TASK Check with the local public works department for plumbing codes. Follow all local plumbing codes when installing components of this system. The system comes supplied with a saddle valve and mounting hardware and is intended to be used on 3/8 inch to 1/2 inch copper tubing, and should be connected to the cold water line only. NOTE: This valve is not to be used on flex lines. Figure 2 - Saddle Valve with Hardware 1.
FAUCET INSTALLATION CONT. 1. 2. Select faucet location. • Make sure the faucet is far enough away so not to interfere with the regular faucet or any other attachments. • If mounting faucet on the countertop, make certain the spout of the faucet will reach over the sink. • Check underneath the sink/countertop for any obstructions and for tool clearances required for mounting the faucet.
. • Always disconnect the battery(s), or other 12v source, before installation or performing any maintenance. • The ballast is supplied with a 6-foot, 2 wire, power cord and 5-foot lamp cord, the ballast must be located so the lamp is easily removed and does not put any tension on the lamp, which could cause damage to the lamp and/or quartz sleeve. All installed wiring should be protected from heat, wear points (abrading) or mechanical stress.
TUBING INSTALLATION • Measure and cut the tubing to desired length. Leave enough slack in the tubing so the system can be easily removed, if necessary. Cut the tubing square; remove all burrs and sharp edges. • Insert tubing into fitting; push until it reaches the tube stop. Avoid kinking or stretching tubing. Check that tubing is secure; gently pull on tubing, tubing should not pull free from fitting.
MAINTENANCE The Bio-Logic® Pure Water PackTM is designed to operate with a minimal amount of maintenance, providing the water quality does not exceed maximum concentration levels, see “Water Quality” in the “Product Application” section. Ordinary maintenance consists of; • Filter cartridge replacement is recommended every 12 months. Over time water pressure to the system faucet will drop, this is an indication that the filter cartridges are nearing the end of their service life.
9. Repeat to replace the second filter cartridge. 10. Lift the handle, of the system faucet, and lock the faucet in the “ON” position. Slowly open the supply valve, and allow the system to fill with water. 11. When water begins to flow from the faucet, allow water to run for several minutes until it is clear with no air bubbles. Turn off the faucet and check between the filter housing and head for leaks. 12.
QUARTZ SLEEVE INSTALLATION, CLEANING OR REPLACEMENT Figure 8 - Quartz Sleeve Cleaning or Replacement Step 4 - Remove Gland Nut From Each End Step 5 - Remove Washer & O-Ring from each end Step 6 - Remove Quartz Sleeve SAFETY EQUIPMENT REQUIRED TO PERFORM TASK 1. • WARNING: Disconnect power to water purifier. For 120v 50/60Hz version using ballast no. 10-0518A or 230v 50/60hz version using ballast no. 10-0514A, remove the ground connector from the chamber, and go to the next step. 2.
REPLACEMENT OF BROKEN QUARTZ SLEEVE Figure 9 - Chamber Head Removal SAFETY EQUIPMENT REQUIRED TO PERFORM TASK CAUTION: Broken Quartz is SHARP. It is recommended that protective goggles and gloves are worn when handling. 1. Follow the steps in “Quartz Sleeve Cleaning or Replacement” to remove lamp and quartz sleeve. WARNING: Disconnect power to water purifier CAUTION: Considerable force may be required to pull purifier from the mounting clips. Exercise extreme care when removing purifier. 2.
15. Lift the handle, of the system faucet, and lock the faucet in the “ON” position. Slowly open the supply valve, and allow the system to fill with water. 16. When water begins to flow from the faucet, allow water to run for several minutes until it is clear with no air bubbles. Turn off the faucet and check the water purifier for leaks. WARNING: Germicidal ultraviolet rays are harmful to eyes and skin.
BALLAST NO. 10-0518A AND 10-0514A HAVE LAMP-OUT PROTECTION If power is applied to the ballast without a lamp connected to the circuit or if the lamp fails, the ballast’s lamp-out protection will prevent the ballast from operating, and a red LED light will illuminate and audio alarm will sound. To reset: disconnect the ballast from power and reconnect or replace the lamp. The ballast must remain disconnected from power for (2) minutes to reset.
DIMENSIONAL DATA Figure 10 - Dimensional Data All specifications, dimensional data, etc are approximate and subject to change without notice.
REPLACEMENT PARTS Figure 11 - Exploded View BIO-1.5 Water Purifier Table 4 - Replacement Parts BIO-1.5 Item No. Description Quantity BIO-1.
REPLACEMENT PARTS Figure 12 - Exploded View Bio-Logic® Pure Water PackTM Table 5 - Replacement Parts Bio-Logic® Pure Water PackTM Item No. Description Quantity BIO-1.5 1 Filter Bracket 1 25-9132A 2A Bio-Logic® 1.5 120v 50/60Hz 1 25-9125A1 2B Bio-Logic® 1.
MAINTENANCE NOTES 19
USER ASSISTANCE Atlantic Ultraviolet Corporation® makes every effort to ensure that the Bio-Logic® Pure Water PackTM Purifiers are products of superior quality and workmanship. This manual describes the installation, operation and maintenance of the Bio-Logic® Pure Water PackTM Please read and become familiar with the contents of this manual before installing or using this unit.