by CONTEMPORARY STEAM ROOM Installation & Operation Manual Note: You must read all installation & operation instructions prior to assembly and use of this unit.
Table of Contents Notice to Installers Packing List Product Features Chart Packing List Rough-In Diagram Water & Electric Requirements Installation Instructions Handle Assembly Temperature Adjustments Faucet Maintenance & Care Faucet Functions & Usage Cleaning, Maintenance & Tips BF1101 Main Control Panel Diagram Description of Functions MID1101 Remote Control Troubleshooting ………………………………………….. ………………………………………….. ………………………………………….. ………………………………………….. ………………………………………….. ………………………………………….. …………………………………………..
|Page Rev 02/2015
NOTICE TO INSTALLERS 1) The distance from the ground to the ceiling has to be minimum of 3.9” higher than the height of the steam room. 2) The water pressure has to be more than 3kg/cm2 (47-72 psi) and, if the pressure is lower than required, you may install a booster to the water supply. 3) Please use a 20-amp 220V GFI breaker for the electrical connection. 4) We advised to have an access panel installed on the side of the electrical/water connections for maintenance and service.
PRODUCT FEATURES DESCRIPTION 3kW Quick heating Self-Draining Steam Generator w/Steam Aromatherapy Cup Multiple Body Massage Jets Hand-held Shower w/ Various water massage settings & adjustable height bracket 8 inch wide water-drenching Rainfall Shower Thermostatic / Anti-scald Faucet “Special Process” Black Tempered Glass walls and front Clear Glass FM Radio Wireless transmitter (optional extra) transmits from any electronic device Hand held Remote control for entire panel control “Chroma-therapy” LED mult
PACKING LIST Glass angle bracket installation instruction Hinge installation instruction A.Glass panel A.Hinge B.Threaded Connector B.Glass door C.Angle Bracket D.Connecting Bolt E.Bolt cap D E A C.Gasket B C D.Screw E D C B A E.Allen wrench SECTION PICTURE OF RUBBER SEAL A B A.Half-moon shape seal B.Corner seal C D C.Magnetic seal D.Door bottom seal GLASS A:Glass A—Main Panel, Black B:Glass B—Back Panel, Black C:Glass C—Side Panel, Black D B A C D:Glass D—Top, Black E G E:Glass
ROUGH-IN DIAGRAMS Note: All diagrams below are for right hand units only. Please reverse for left hand units. M-A6020 (43×31.5×84in.) M-A6028 (59×40×84in.) A. Cold water in B. Power jack(AC30A) C. Hot water in M-A6023 (35.4×35.4×84in.) M-A6027 (59×32×84in.
WATER AND ELECTRICITY INSTALLATION INSTRUCTION FOR ALL MODELS (1) Water: Two water lines for cold and hot water respectively ½-inch National Pipe Thread (NPT). (2) Power: Power requirement: Single-phase three-wire 220V power supply.
INSTALLATION INSTRUCTIONS FOR MA6020 & MA6023 Note: Silicone joints & seams where needed Note: Determine the drain setup. There needs to be a 3/8 inch diameter hose connected from the steam box to the main drain. 1. Place shower tray in the corner where it will be permanently located. Note: The handing (R/L) of your unit determines which side the mounting plate goes (ie: A right handed unit has the mounting plate on the right side) 2.
8. Install the angle bracket to the holes on glass B (black back panel). Connect with screw. Tighten snugly, but leave enough tension to adjust. Insert the corner seal on the on the left side of glass B. Note: Attach glass shelf brackets to back of panel before proceeding. 12. Place glass C into the slot onto the base and insert into the corner seal of glass B. Note: Glass B is the black panel, and glass C is a black panel. Line up the installation holes and connect glass B and glass C. 9.
15. Connect the rainfall showerhead water line to faucet, screw in. Also, connect the light, fan and radio. Then locate the middle water pipe, which is under the faucet, and connect it to the steam box water inlet. Secondly, connect the black steam line, which is on the side of the steam box, to the steam outlet. Connect steam box drain line to the steam outlet drain. Finally, connect the cold and hot water lines to the water manifold, the red one is for hot water, while the blue is for cold.
HANDLE ASSEMBLY TEMPERATURE ADJUSTMENTS TRIM FLANGE ATTACHMENT Position Flange (A) on the Valve (B) with drain hole (C) at the bottom. Place Protective Washer (D) on the short end of the reversible Retainer Sleeve (E). Screw Retainer Sleeve (E) onto threaded section of the Stem and Bonnet (G). Tighten Retainer Sleeve (E) by hand until Flange (A) is snug to finished wall surface. If the short end of the Retainer Sleeve (E) is too short, reverse it to use the longer end.
MAINTENANCE & CARE Disassembly: 1. Replacement parts may be available at Lowes or Home Depot. 2. When replacement parts are not available, please write or call Price Pfister Consumer Service. 3. Always turn off water and release pressure before working on your faucet. Dripping from either the tub spout or shower head. Clean the cartridge assembly (D). check to ensure the two oval ORings (F) on the back of the cartridge (E) are in place. Reassemble cartridge, stem and bonnet assembly and handle.
FAUCET FUNCTION AND USAGE Water Diverter handle o Turn the diverter handle according to the signs marked on its face. When you use the hand held shower, turn the knob to the hand held shower sign; When you use the massage jets, turn the knob to the back massage sign. When you use the rainfall shower head, turn the knob to the rainfall shower sign Cold Water and Hot: o Turn the faucet to left and right to increase/decrease the water temperature. CLEANING AND MAINTENANCE 1.
BF1101 CONTROL SYSTEM FOR MA602X SERIES 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Time & Temperature setting Rainfall shower Body Massage Jets Top light Time / Temperature Increase Time / Temperature Decrease Circulation Fan Back light (not active for this model) Sauna (not active for this model) Radio on/off and CD connection 11. 12. 13. 14. 15. 16. 17. 18. 19.
DESCRIPTION OF FUNCTIONS Not in the same order above 1. ON/OFF Key Under ON state, press “ON/OFF” Key on the panel to start the system, and the top light is turned on, all functions are activated on the panel, the back light is on, LCD shows the ambient temperature and all icons are lit; press the “ON/OFF” to shut off the system. Press other keys except “ON/OFF” key under standby and OFF state, the backlight will come on, if the systems is not turned on, the backlight will be turned off in 30 seconds.
MID-1101 REMOTE CONTROL SYSTEM Note: Sauna key does not have any functions for this model Note: Rainfall shower head and body jets are controlled by manifold only Note: “B” light does not have any functions for this model Note: Rainfall shower and body massage jets are electronically controlled.
TROUBLESHOOTING Problem Unit does not start Switch failure Automatic shutdown No steam Automatic Protection No sauna Temperature is too high Steam is Shutting off Water from steam outlet Audio not working Possible Reason Solution 1. Power line is not connected properly. 2. Insufficient power supply. 3. Fuse is damaged 4. Current circuit breaker is damaged. 1. Current circuit breaker tripped or damaged 2. Short circuit 1. The intake valve or drain valve is damaged 2.
by 19 | P a g e Rev 02/2015