Parts List/Tune Up Info

Tune-up procedure
Each device is individually calibrated during manufacturing. Measurement is
performed in a full calibrated setup.
Measurement procedure is outlined below:
1. Set the device to operational voltage and on a predefined band class
and channel.
2. The maximum output power is measured when the power control bit is
set as all UP bits. The RF output power will be adjusted equal or lower
than tested power shown in the test report.
The user has no possibility to change these settings.
Tune up procedure shall be over the power range or at specific operating
power levels.
1. It must provide an operational voltage to turn on the device and
on one certain channel in service mode by means of company
proprietary software.
2. The Base station simulator measures the device specific RF
characteristics.
3. The maximum gains of each individual device are adjusted until
the target value met.
Conducted Power Table
Channel
Mode
Target Power (dBm)
Tolerance (dBm)
462.5625
FRS
8.5
(-0.5,+0.5)