User's Manual

H3-EM-69-100 Electronic Swinghandle
Operating Instructions
J-H3-EM-69-100-M_revB Page 1 of 4
Package Contents
H3-EM-69-x00 Electronic Swinghandle (qty1)
EM-0-45827 M3x25 POZIDRIV
®
Mounting Screws (qty 4)
EM-0-47151 M3x14 POZIDRIV
®
Mounting Screw (qty 1)
EM-0-45825 Rotation Limiter (qty 1)
E5-C-04 Pawl Screw (qty 1)
M3-0-24943-11 Lock Plug Screw (qty 1) (optional)
EM-0-45826 Top Mounting Bracket (qty 1)
EM-0-45822 Bottom Mounting Bracket (qty 1)
Operating Instructions (qty 1)
H3-EM-69-x00 Electronic Swinghandle
3
4
1
2
1. Handle
2. Prox Reader
3. Tri-Color Status LED
4. Lock Plug (optional)
Features
Installed 125kHz proximity reader module with RS232 data
output
Remote lock and unlock capability
Single or multi-point lock actuation
Momentary or continuous lock actuation
Tri-color LED (blue/magenta/red) to indicate lock and handle
status
DIN lock manual override
Accommodates both left and right doors
For indoor use only
WARNING: The H3-EM-69-000 is shipped without a lockplug. This
product must be paired with a Southco-approved lock to function properly.
Use with an unapproved lockplug voids the product warranty.
Contact Southco for additional support.
Specifications
Actuator Module
Supply Voltage (V
SUPPLY
): 12VDC to 24VDC (NOTE: Status LED will blink
red if the supply voltage is out of range.)
Standby Current: 50mA maximum at 12VDC
Operating Current: 200mA maximum at 12VDC (with no external
mechanical load applied to handle
Stall Current: 1A maximum (at 12VDC, limited to 2 seconds)
Operating Transit Time: 1 second maximum (NOTE: Power must be
present during transit times. If power is
removed while the lock slide is moving to the
unlock position, then the control input signal
must be asserted again. If power is removed
while the lock slide is moving to the lock
position, it will complete it’s cycle when power is
restored.)
Electronic Unlock Time: 3 seconds minimum
Open Collector Outputs: Rated for V
SUPPLY
, 100mA maximum load
Proximity Reader Module
Supply Voltage (V
CC
): 12VDC to 24VDC
Operating Current: 50mA maximum (no external devices
attached)
Transmit Frequency: 125kHz FSK
TX Data Output Voltage: -12VDC / +12VDC
COM Port Settings:
parameter
setting
bits per second
9600
data bits
8
parity
none
stop bits
1
flow control
none
Mounting and Installation
Please refer to Southco trade drawing J-H3-EM-69-100 for mounting and
installation details.
NOTE: Use a #1 POZIDRIV
®
driver when installing the mounting
screws. See Southco trade drawing J-H3-EM-69-100 for additional details.

Summary of content (4 pages)