User's Guide

DETECTOR VALVE
1. Valve Charging Knob. This Control is used to
“Recharge” the valve after it has closed. To achieve this
carefully rotate the knob clockwise 90 degrees from the
off position until it stops (this point is indicated on the
body). Carefully release the knob and it will remain in
position.
2. Valve Test Button. This is the Detector Valve test
button and should only be used if you cannot reach the
Remote Controller and need to shut off the incoming water
supply. The valve must then be manually reset as
described in (1) above.
3. Battery Cover. To remove the battery covers gently
press the clip in the direction of the arrow and then pull
upwards. The batteries require careful insertion to ensure
the correct polarity and connection. Only use prime quality
AA batteries and only replace a complete set of cells. Take
extreme care in the use and disposal of batteries as there is
a risk of fire or explosion if cells are not handled or disposed
of correctly; the SME 110vac mains transformer is available
as an optional extra.
Issue 12 June 2005
Solutions Made Easy Limited
2850 North Pulaski
Chicago, IL
60641, USA
Free Phone 1800 621 1556
LEAK TRACKER
LD-20D
USER GUIDE
110VAC ONLY USE ONLY
FCC ID : SSULD20D100
FCC ID: SSULD20D200
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1)this device may not cause harmful interference, and
(2) this device must accept any interference received,
including interference that may cause undesired operation.
IMPORTANT NOTE FOR
HOUSE BUILDERS
The LD20-D Leak Tracker has features
which protect new homes during the
final stages of construction prior to the
“handover”.
Once the LD20-D is installed it is
recommended that the system is set to
the Manual Mode (15 minute setting).
If a higher degree of protection is
required select the away mode
This setting will only allow 2 minutes of
high water flow and 10 minutes of low
water flow (3gallons/hr or less) sufficient
for cleaners, tradesmen and sales staff
etc, to carry out their duties. In the event
of a need for more water the valve can
be simply reset to restart the water flow.
To ensure the system is not tampered
with or abused, the controller can be
removed from the new home to a safe
keeping place. The valve will still offer
maximum protection but without the
audible alarm feature. The incoming
homeowner can then be presented with
the controller & user guide instructions.