Figure 5.6 – Dimension used to install ROU on the WALL ROU Wall Mount Installation Turn M12 Fixing Screws by half on the wall and fully fix the screw with a Wall Mount Bracket on it. For convenience, the Wall Mount Bracket has fixing holes to let you easily mount an enclosure. Turn the M5 Wrench Bolt by half at each side of the Heatsink of the enclosure.
Put the enclosure with the M5 Wrench Bolt fixed on the fixing groove and fix the M5 Wrench Bolts into the remaining fixing holes. In this case, you will use 12 M5 Wrench Bolts in total except bolts used for the fixing groove. ROU Rack Mount Installation Like other units, ROU is designed to be inserted into a rack. The unit occupies around 13U of space except cable connection.
ROU component ROU has the following components: No.
In addition, RDU can be inserted and removed to provide service for desired band (Optional). 5.3.2 ROU Power Cabling ROU supports both of DC-48V and AC120V of input power. As RPSU for DC-48 and RPSU for AC120V are separated from each other, you need to select one of them in case of purchase order. RPSU for DC -48V and RSPU for AC 120V have the same configuration and capacity while each of the units uses different input voltage from each other.
MC Connector Lug Naming RPSU Terminal naming Remark numbering AC DC AC DC A AC_H -48V AC-H -48V B AC_N GND AC-N IN_GND C GND DC NC FG FG Check if the connection is the same as one seen in the table above and make sure to turn the power ON. 5.3.3 Optical Cabling ROU makes optical-electronic conversion of TX signals from upper ODU and OEU and makes electronic- optical conversion of RX signals. ROU has one optical module in it.
Optical cables should be inserted into Optic Port outside of ROU. Using an optical slack devices in ROU, you need to coil around one or two roll of cables to be connected with the optical adaptor of ROPTIC. At this time, curvature of the optical cable should be at least 10Ø to prevent insertion loss from being increased. Through GUI, check if PD value of ROPTIC is in a tolerable range (+4~-1dBm). 5.3.
You can insert a RDU into any slot. It is not possible to provide services with a RDU module alone; you need to connect the module with Cavity BPF in any case.
① Combine RDU 800PS with 800PS BPF (As it is a plug type, push the unit to combine with BPF.) ② Insert the combined 800PS+850C BPF Ass’y into any slot of ROU.
How to RDU install 850C Ass’y The following components are required: No. Unit Description Remark 1 RDU 850C RF Module 2 850C BPF BPF 3 850C TX RF CABLE SMA(M) to SMA(M), 310mm 4 850C RX RF CABLE SMA(M) to SMA(M), 310mm ① Combine 850C RDU with 850C BPF (As it is a plug type, push the unit to combine with BPF.) ② Insert the combined 850C+850C BPF Ass’y into any slot of ROU.
How to install RDU 800PS+900I+PA Ass’y The following components are required: No. Unit Description 1 RDU 800PS+900I+PA RF Module 2 800PS+900I+PA BPF BPF 3 800PS+900I+PA TX RF CABLE SMA(M) to SMA(M), 460mm 4 800PS+900I+PA RX RF CABLE SMA(M) to SMA(M), 380mm Remark ① Combine RDU 800PS+900I+PA with 800PS+900I+PA BPF (As it is a plug type, push the unit to combine with BPF.) ② Insert the combined 800PS+900I+PA BPF Ass’y into any slot of ROU.
800PS+900I+PA TX TX OUT - 800PS+900I+PA RX RX IN - How to install RDU 850C+700PS Ass’y The following components are required: No. Unit Description 1 RDU 850C+700PS RF Module 2 850C+700PS BPF BPF 3 850C+700PS TX RF CABLE SMA(M) to SMA(M), 470mm 4 850C+700PS RX RF CABLE SMA(M) to SMA(M), 400mm Remark ① Combine RDU 850C+700PS with 850C+700PS BPF (As it is a plug type, push the unit to combine with BPF.) ② Insert the combined 850C+700PS BPF Ass’y into any slot of ROU.
850C+700PS RX RX IN - How to install RDU 1900P+AWS-1 Ass’y The following components are required: No. Unit Description 1 RDU 1900P+AWS-1 RF Module 2 1900P+AWS-1 BPF BPF 3 1900P+AWS-1 RF CABLE SMA(M) to SMA(M), 390mm 4 1900P+AWS-1 RF-01 SMA(M) to SMA(M) Remark Semirigid ① Combine RDU 1900P+AWS-1 with 1900P BPF (As it is a plug type, push the unit to combine with BPF.) ② Connect BPF 1900P port with 1900P port of 1900P RDU through 1900P+AWS-1 RF01 RF CABLE.
1900P+AWS-1 RDU AWS-1+1900P COM 1900P BPF 1900P+AWS - How to install RDU VHF+UHF Ass’y The following components are required: No. Unit Description 1 RDU VHF+UHF RF Module 2 RDU VHF+UHF RF CABLE SMA(M) to SMA(M), 460mm 3 RDU VHF+UHF RF CABLE SMA(M) to SMA(M), 380mm Remark ① Insert the combined VHF+UHF RDU into any slot of ROU. ② Connect RDU VHF+UHF Port with ROU VHF+UHF Port through VHF+UHF RF CABLE How to install RDU 850C+700LTEC Ass’y The following components are required: No.
4 850C+700PS RX RF CABLE SMA(M) to SMA(M), 400mm ① Combine RDU 850C+700 LTEC with 850C+700PS BPF (As it is a plug type, push the unit to combine with BPF.) ② Insert the combined 850C+700 LTEC BPF Ass’y into any slot of ROU.
You cannot insert the same module and band into MULTIPLEXER port at the same time. For example, you are not supposed to insert both of 800PS RDU and 800PS+900I+PA RDU into ROU at the same time. In the same way, you cannot concurrently insert both of 850C RDU , 850C+700PS RDU and 850C+700LTEC into ROU. Information of LED at the front RDU RDU has the structure of enabling a random RDU to be inserted into three slots. ROU can be equipped with a total of three RDUs.
and the other slots ramian reserved, you need to insert BLANK cards into the other slots. When RDU is inserted into ROU, LED of the front panel shows the following information: LED Description Power is not supplied ON Power is supplied.
Up to three RDUs can be inserted. If one or two units of them are used, then you need to terminate the unused slot of RDU with a BLANK card. 5.3.
RDU 1900P+AWS-1 RDU VHF+UHF FULL 93W Both HPA ON 1900P 46W AWS-1 HPA OFF AWS-1 46W 1900P HPA OFF FULL 68W Both HPA ON VHF 47W VHF HPA OFF UHF 47W UHF HPA OFF FULL 74W Both HPA ON For power consumption of ROU, the common part consumes 17W. Depending on the quantity of each RDU, you can add overall power consumption of ROU. Only, in case of Dual-Band signals, power consumption is calculated respectively when HPA of the other party is turned OFF and two HPA devices are turned ON.
5.4.2 OEU Power Cabling The input power of OEU is DC -48V. You need to connect DC cable with the Terminal Block seen at the rear of OEU. Terminal -48V NC GND Color of cable Blue color Description Remark Input range: -42 ~ -56Vdc Not Connected Black color Before connecting the power terminal, you need to connect “+” terminal of Multi Voltage Meter probe with the GND terminal and then connect “–“ terminal with -48V to see if “-48Vdc” voltage is measured.
Note that OEU does not operate if the “+” terminal and the “–“ terminal of the -48V power are not inserted into the accurate polarity. 5.4.3 OEU Optic Cabling OEU is connected with upper ODU. With DOU inserted in it, the unit is connected with ROU. As OEU has a shelf with EWDM in it, the unit makes electronic-optical conversion of TX signals from ODU and makes optical-electronic conversion of RX signals. In addition, OEU can be equipped with up to two DOUs.
marred with dirt, it should be covered with a cap during move. When devices are connected through optical cables, you need to clear them using alcohocol to remove dirt. 5.4.4 Insert DOU to OEU Into OEU Shelf, up to two DOUs can be inserted. DOU module is in Plug in Play type. When you insert DOU in OEU, insert the unit into the top DOU1 slot first. You can be careful as the number is silk printed at the left. The following figure shows installation diagram of OEU with one DOU inserted in it.
you nedd to install BLANK UNIT into them. 5.4.5 Consumption Power of OEU OEU has -48V DC Power supply in it. ODU can be equipped with up to two DOUs. Depending on the quantity of DOU, power consumption is varied. The following table shows power consumption of OEU: Part Unit Consumption Power Remark Shelf EWDM Common Part 12W ERF EPSU OEU_4 DOU 1 EA 23W OEU_8 DOU 2 EA 33W 5.5 5.5.1 ADD ON V/UHF ROU Installation AOR Enclosure installation AOR is designed to be water- and dirt-proof.
AOR should be installed above or under of exisitng ROU Figure 5.8 – How to install AOR Figure 5.9 – Dimension used to install AOR on the WALL ROU Wall Mount Installation Turn M12 Fixing Screws by half on the wall and fully fix the screw with a Wall Mount Bracket on it. For convenience, the Wall Mount Bracket has fixing holes to let you easily mount an enclosure. Turn the M5 Wrench Bolt by half at each side of the Heatsink of the enclosure.
Figure 5.10 – Installation flow diagram when AOR installs on wall Put the enclosure with the M5 Wrench Bolt fixed on the fixing groove and fix the M5 Wrench Bolts into the remaining fixing holes. In this case, you will use 6EA of M5 Wrench Bolts in total except bolts used for the fixing groove. ROU Rack Mount Installation Like other units, AOR is designed to be inserted into a rack. The unit occupies about 4U of space except cable connection.
temperature is increased. Therefore, we recommend that AOR should be installed with at least constant space from existing ROU(above 2U) The following shows the installed diagram on rack with exisiting ROU Figure 5.10 – Installation flow diagram when AOR installs in the rack AOR components AOR has the following components: No.