Document Number: SYSFS Reviewed By: SYSTEM Release Date: 1-DEC-07 Koito MRS User Guide v1.5 This document is Solectek CONFIDENTIAL and may not be reproduced without written permission. V1.
1. Introduction For the Phase II release, the Configuration of the MRS boardset can be changed in three ways: HTTP GUI, Telnet and Configuration File. 1. 2. 3. 2. The GUI is functional, though per Solectek schedule, is not completely functional. Telnet may be used to work with the commands listed in this document. The Configuration File may be offloaded, modified and re-stored on the MRS. Unit Power The MRS boardset is intended to be powered via the 2pin, +48V connector on Minotaur.
set_config VARIABLE VALUE eg. set_config ENET0_IPADDR 10.20.20.7 (Set the ENET0_IPADDR). set_config DEV_MODE ap (set the device operation mode to AP). IMPORTANT: All set_config commands should be followed by a save_config command which stores the changes to permanent Flash memory. A reboot is also required for most command to take effect. show_config You may use the show_config command to display the value of a configuration variable. eg. show_config ROUTER_TYPE 5.2.
• http - Can be used only to download a file. The command is: wget http://ip-address/path-to-file 6. Configuration Parameters Note: Parameters are case sensitive Note: Parameter format below is correct for CONFIG_VARS file usage. When used with set_config, the ‘=’ is replaced by a space. • ENET0_IPADDR=aa.bb.cc.dd - IP address of the Ethernet Interface - Used as the Bridge address when the system is operating in Bridge mode. • ENET0_NETMASK=aa.bb.cc.
• WIFI_PSK=32 hex digits PSK - Used in shared mode • RADIUS_SERVER=a.b.c.d - IP address of radius server. Used when WIFI_ENC=ieee8021x. • RADIUS_SECRET=secret - Secret shared with the radius server • ADMIN_NAME=admin - For HTTP login request for the GUI • ADMIN_PASS=password - For the HTTP login • HTT_AUTH_REQ=on - on or off - When on, secure web-pages require login (with ADMIN_NAME) • SERIAL_NUM=xxx - This is the serial number of the unit. It should not be changed.
7. Upgrading Software, Phase3 SW release The method described below is a temporary method to upgrade software prior to the user-friendly approach to be delivered in the Phase3 release. WARNING: updating the MRS and AP software using the following procedure will reset the confi guration file. All configuration information will be reset to default, including the Ethernet MAC address. It is vital that the Ethernet MAC address configured properly, after the upgrade is complete.
fis create -b 0x800000 -l 0x20000 -f 0x505c0000 solconfig • • Power cycle the Minotaur board and verify successful reboot Via Serial Console, or Telnet access, set desired system configuration parameters, including the Ethernet MAC address recorded earlier. 8. FCC Radio Frequency Interference Statement FCC ID: KA358MRS1 This device is certified to comply with Part 15 of Federal Communications Commission (FCC) Rules. Operation is subject to the following two conditions: 1.
1.1 03-Oct-07 D. Gell Added SW upgrade section 1.2 08-Nov-07 D. Gell SW upgrade section modified 1.3 15-Nov-07 P. Palreddy 1.4 1.5 15-Nov-07 01-Dec-7 D. Gell D. Gell SW upgrade section modified to use Windows XP and TFTPDWIN server application Added FCC information Added reminder that a Redboot based upgrade defaults the configuration file, including resetting the Ethernet MAC address 1.6 19-Dec-07 D.