User manual

Conversion Kit
10
8 Combustion products
The combustion products may be extracted
by means of hoods connected to a natural
draught chimney whose efficiency is certain
or via forced extraction. An efficient
extraction system requires precision
planning by a specialist qualified in this
area and must comply with the positions
and distances indicated by the applicable
standards.
When the job is complete, the installer must
issue a certificate of conformity.
1 Extraction using a hood
2 Extraction without a hood
A Single natural draught chimney
B Single chimney with extractor fan
C Directly outdoors with wall- or window-
mounted extractor fan
D Directly outdoors through wall
Air
Combustion products
Extractor fan
9 Final operations
• Completely fill out the conversion label
(part no. 92849A078) and attach it to
the rear of the appliance. Do not cover
any other labels with the conversion
label.
• Over time the gas taps may become
difficult to turn and get blocked. Clean
them internally and replace the
lubrication grease.
• Save the nozzles removed from the unit
along with these instructions for possible
future use.
• For installation of the appliance at high
altitude, please consult your local gas
company for their recommendation on
the correct orifice sizes and any other
necessary adjustments that will provide
proper gas combustion at specified
altitudes.
10 Natural Gas
To convert back to Natural Gas, follow
steps 1 through 7 and replace the nozzles
in the order in which they were removed.
Lubrication of the gas taps should
be performed by a specialised
technician.