User manual

Conversion Kit
8
7 Burner and nozzle characteristics tables
To adjust the range for LP gas or to return to Natural Gas use, refer to the charts below.
Natural Gas AUX SR UR DUAL int DUAL est
QT (BTU)
4500 8000 20000 4500 15500
Injector Ø (mm)
0.90 1.20 0.90 + 1.80 0.90 1.75
QR (BTU)
1200 1600 5200 800 4200
LP AUX SR UR DUAL int DUAL est
QT (BTU)
4200 7500 18000 4000 14000
Injector Ø (mm)
0.60 0.80 0.54 + 1.10 0.54 1.10
QR (BTU)
1200 1600 5200 800 4200
By-pass (mm)
0.33 0.39 0.70 0.30 0.63
NOTE: Save the nozzles that were removed from the appliance along with these
instructions for possible future use.
WARNING
FIRE HAZARD
Use a soapy solution to check that it is leak-tight.
Never test for gas leaks with a match or other flames.
Failure to follow this instruction can result in loss of life or fire.