On-Line Owner’s Manual Containing Cautionary FCC & IC Statements September 30, 2011 Wall-Mounted Wireless Thermostat Models: 2441T and 2441TH FCC ID: SBP2441T IC: 5202A-2441T The owner’s manual below may be accessed freely via the Internet with any web browser and supports the PDF format. http://www.smarthome.com/2441TH.html Complies with Section 5 of FCC document 784748 D01 Labeling Part 15 18 Guidelines v07 where cautionary statements in the user manual may be provided over the Internet.
TempLinc Owners Manual INSTEON® Thermostat (#2441T) Page 1 of 22 Rev: 9/30/2011 1:26 PM
About TempLinc 3 TempLinc – Features & Benefits What’s in the box? 3 3 Thermostat Button Overview 4 Thermostat Operation and Programming Thermostat Mode Button Operation Thermostat Energy Button Operation Thermostat Set Button Operation Thermostat Time / Sensor Button Operations Thermostat Program Button Operation Thermostat Fan and Hold Button Operations Thermostat Master Button Operation 5 5 6 7 7 8 10 11 Installation Tools Needed Preparation Wire Connections Test Operation 12 12 12 12 13 Adding
About TempLinc TempLinc is a 7 day programmable INSTEON-compatible thermostat. It comes in two variants, with and without a humidity sensor. The humidity sensor model also includes 2 stage heating and cooling, while the non-humidity sensor device is a single stage device. Expand the system by creating extra temperature zones in your home. Simply add wireless TempLinc zone thermostats to your system.
Thermostat Button Overview 1 2 9 8 7 6 5 4 3 1 Up/Down adjust the temperature setpoint based on the mode you are currently in 2 Mode allows the user to select the current operational mode of the HVAC system. It cycles between Off, Auto, Cool and Heat 3 4 5 Energy button is designed to be a very quick to use option that saves energy (and money). When you press it, it will back off the set point by a specified value. The default value if 5 degrees from the current setting.
Thermostat Operation and Programming Thermostat Mode Button Operation Off Mode: No set points are shown Up / Down do not do anything Auto Mode: Both cool and heat set points are shown Up / Down move both together with a set gap Cool Mode: Only Cool set point is shown Up / Down do not do anything Heat Mode: Only Heat set point is shown Up / Down changes the Heat set point Page 5 of 22 Rev: 9/30/2011 1:26 PM
Thermostat Energy Button Operation The Energy button is designed to be a very quick to use option that saves energy (and money). When you press it, it will back off the set point by a specified value. The default value is 5 degrees from the current setting. To change the default offset value away from 5 degrees, you must use HouseLinc.
Thermostat Set Button Operation Set button is for INSTEON linking and unlinking as well as accepting the current programming step and going to the next one in sequence. For INSTEON functions, it works like Set does for other INSTEON devices. Operating details can be found in other sections. Thermostat Time / Sensor Button Operations The Time / Sensor button allows the user to set the date, time and select the sensors/humidity to display.
4th press of Time / Sensor: Selects which sensor to show in position 1 Up / Down cycles through 1-9 with none then again 5th press of Time / Sensor: Selects which sensor to show in position 2 Up / Down cycles through 1-16 with none then again 6th press of Time / Sensor: Selects which Humidity sensor to show Up / Down cycles between 1 (no number) and 2 Thermostat Program Button Operation The Program button allows you to setup the various pre-programmed modes (Wake, Leave, Return, and S
2nd press of Program: - Selects day setting - Up / Down cycles between 7 days, weekdays, weekend days, each day - As you select a different day option, the current pre-programmed settings for that day (or group of days) are displayed 3rd press of Program: - Selects Start / Time - Up / Down cycles through time in 15 minute increments - Press and hold of Up / Down cycles faster NOTE: AM / PM changes automatically as needed 4th press of Program: Selects Cool set point Up / Down cycles through temperature
Thermostat Fan and Hold Button Operations Fan button operations The Fan button cycles between Auto and Always On. On the display, it simply cycles the text Fan Always to show or not. Hold button operations The Hold button over-rides a pre-programmed mode until either: o The mode / temp is changed manually by user Including on a remote thermostat / templinc o Hold is turned off NOTE: If the next pre-programmed time comes, it will be ignored unless one of the above items occurs.
Thermostat Master Button Operation 1st press: - Makes the local TempLinc the master Before pressing Master button: Notice that remote sensor 2 is currently the Master After pressing Master button: Notice that remote sensor 2 is no longer the Master The local temp now is Master controlling temperature Page 11 of 22 Rev: 9/30/2011 1:26 PM
Installation CAUTIONS AND WARNINGS Read and understand these instructions before installing and retain them for future reference. IMPORTANT! If you are not knowledgeable about, and comfortable with, HVAC circuitry, you should have a qualified HVAC professional install TempLinc for you. Tools Needed - Flat blade screwdriver Wire cutter / stripper Preparation Proper installation of the thermostat will be accomplished by following these step by step instructions.
[Connection diagram] Test Operation 1) Turn the power on to the Heating/Air Conditioning system 2) Press the MODE button repeatedly until the HEAT icon appears in the display. Press the UP or DOWN buttons until the set temperature is 10 degrees above room temperature. The furnace should turn on. 3) Press the MODE button repeatedly until the COOL icon appears on the display. Press the UP or DOWN buttons until the set temperature is 10 degrees below room temperature. The air conditioner should turn on.
TempLinc Wireless Zone Thermostat will (Beep)-(Beep) 3) Test the link by pressing the Master button on the TempLinc Wireless Zone Thermostat INSTEON Programming Linking as a Responder Linking to On 4) Set thermostat to desired state 5) Put controller in linking 6) Press & hold Thermostat Set button Thermostat Set LED goes GREEN for xx seconds Thermostat will (Beep) 7) Linking complete with a (Beep)-(Beep) / LED off Linking to Off 1) Set thermostat to desired state 2) Put controller in linking 3) Simultaneo
Group 2 - Heating mode change (scene control) Group 3 - Fan mode change (scene control)* Group FE - broadcast on any change (info only)* * Can only be configured via software. NOTE: The Wireless TempLinc can also be linked as a controller to Group 1 and 2 but it will operate if there’s a TempLinc or not. When it is linked as a controller of a TempLinc, the setpoints between Wireless TempLinc and TempLinc will always be matched.
Seen if press Down arrow Can alternate between these 2 by pressing Up and Down Unlinking 1) Press & hold Thermostat Set button until it beeps Thermostat Set LED blinks GREEN Thermostat will (Beep) as a responder 2) Press & hold Thermostat Set button to put it in unlinking Thermostat Set LED blinks RED Thermostat will (Beep) LCD display indicates the group that you are unlinking from 3) Press: Up arrow to unlink from Group 1, Cooling mode changes Down arrow to unlink from Group 2, Heating mode change
Upon entering Unlinking mode Defaults to Cooling mode Seen if press Down arrow Can alternate between these last 2 screens by pressing Up and Down Factory Setup Modes To enter a Factory Setup Mode: 1) Press Mode, Up, and Down buttons simultaneously for 3 seconds to enter all of the Factory Setup Modes below 2) All LCD segments will turn on Page 17 of 22 Rev: 9/30/2011 1:26 PM
Factory Programming Mode 1) Once in Factory Setup Mode, press the Program button and select from one of the following (Press Mode button to step through the options): Sub-mode 1: Beep on button press (Default is Off) Sub-mode 2: Programming lock (Default is Off) Sub-mode 3: Button Lock (Default is Off) Sub-mode 4: Temperature format select (Default is Fahrenheit) 2) Press the Up or Down button to change a setting Sub-mode 1: Beep on button press (Enable / Disable) a. Up arrow = On b.
Sub- mode 4: Termperature format select (C or F) a. Up arrow = C b.
Humidity Calibration Mode 1) Once in Factory Setup Mode, press the Sensor button 2) Press the Up or Down button to select the current humidity level The display will appear similar to the following The top numbers represent: 40 What the humidity sensor sees -92 or 17 the offset from current reading The offset is from -10 to +10 The displayed number needs to be multiplied by 0.
Xx = unsuccessful 4) Device will return to normal operations Option 2 1) Press & hold Thermostat Set button until it beeps Thermostat Set LED blinks GREEN Thermostat will (Beep) as a responder 2) Press & hold Thermostat Set button again until it beeps Thermostat Set LED blinks RED Thermostat will (Beep) LCD display indicates the group that you are unlinking from 1) Double tap the Set button 2) Press and hold the set button for ~10 seconds 3) Continue pressing and holding for ~10 seconds Device will blink al
Certification and Warranty FCC & Industry Canada Compliance Statement This device complies with FCC Rules Part 15 and Industry Canada RSS-210 (Issue 8). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence.