D000587 Rev B SmartBypassTM User Guide © 2019 Smart Wires Inc. The information and methodologies outlined herein and their expression in this document is copyrighted with all rights reserved. Copying or distributing it without prior written permission is strictly prohibited.
D000587 SmartBypass User Guide Revision A Table of Contents 1 Scope-------------------------------------------------------------------------------------------------------------------------------------------- 3 2 Purpose ---------------------------------------------------------------------------------------------------------------------------------------- 3 3 Abbreviations -------------------------------------------------------------------------------------------------------------------------------- 3
D000587 SmartBypass User Guide Revision A Preface 1 Scope This user guide applies to the operation and purpose of the SmartBypass. It also provides the FCC compliance information. 2 Purpose The purpose of this document is describe to the user the purpose, components, operation and communication method of the SmartBypass.
D000587 SmartBypass User Guide Revision A 5 Electrical Operation of Single Module The SmartBypass comes in several different models as shown in Table 2. The SmartBypass can operate at line currents of thousands of amps during normal bypass operation and withstand different fault current levels depending on the model. The SmartBypass models are differentiated by continuous current rating and maximum fault current rating.
D000587 SmartBypass User Guide Revision A Model SmartBypass 2000-63 SmartBypass 2000-50 SmartBypass 2000-38 SmartBypass 2000-25 SmartBypass 2000-12 SmartBypass 4000-63 SmartBypass 4000-50 SmartBypass 4000-38 SmartBypass 4000-25 SmartBypass 4000-12 Continuous Current Rating (A RMS) 2000 2000 2000 2000 2000 4000 4000 4000 4000 4000 Maximum 2-Hour Emergency Current (A RMS) 2160 2160 2160 2160 2160 4320 4320 4320 4320 4320 Fault Current Rating (kA RMS for 1 s) 63.0 50.4 38.0 25.2 12.6 63.0 50.4 38.0 25.
D000587 SmartBypass User Guide Revision A 2. 7 Injection Mode – The normally closed contactor S1 is open. SmartBypass allows the Smart Wires series compensation devices to inject their reactance across its terminals in series with the line. Product Components The individual components of the SmartBypass are shown in Figure 7-1.
D000587 SmartBypass User Guide Revision A 9 Regulatory Compliance User Notice: FCC: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.