User's Manual

3002P Instruction
LCD DISPLAY
1. PROGRAM FOR: Flashes when programming days of week and periods of the day. When in
normal state, only current DAY displays. When programming or in PROGRAM mode, both day
and week will display.
2. DAY – Flashes when current day or day of week is being programmed.
3. PERIOD – Flashes when current period of day or period of week is being programmed.
4. MODE – Indicates operation MODE of system. ON indicates the system is on, either
manually or thermostatically. OFF indicates the entire system is turned off. THERMO indicates
the system will automatically cycle ON/OFF, depending on programmed SET temperature.
PROGRAM – Indicates the system is operating with PROGRAMMED settings.
5. START AT – Flashes when programming the time to turn system ON.
6. SET – Indicates desired SET room temperature, when in THERMO or PROGRAM mode.
7. 0F/ 0C – Factory programmed in 0F.( 0C indicates degrees in Celsius.)
8. TIME/TEMP – Displays the CURRENT room temperature. In same frame the current time will
display in AM or PM. You must depress the TIME/TIMER button to display current time.
9. LOW – Battery power is low. Replace batteries within 2 weeks.
10. TIMER – When displayed indicates countdown timer in operation.
11. OVERRIDE – Displays when “programmed”” SET temperature is overridden.
12. FLAME – Single or double flame symbol indicates burner/valve is operational.
13. HOLD – Displays when “programmed” SET temperature is overridden and will hold that
temperature until cancelled or next program period change.
14. CP – Displays when CHILD PROOF “LOCK-OUT” is engaged. Pressing the UP and TIMER
buttons together, engages CP.
15. SWING- Displays in SET frame when setting TEMPERATURE DIFFERENTIAL.
16. FAN – Indicates the fan is on (when fan blade displayed). OFF indicates fan is not in
operation.

Summary of content (6 pages)