Table of Contents Introduction 01 Special Features 03 Warning and Safety Notes 05 Program Flow Chart 08 Explanation of Buttons 09 Power and Battery Connection 10 Charge Operation 12 Lithium Battery Program (LiPo/LiFe/Lilon/LiHV) 13 NiMH/NiCd Battery Program 16 Pb Lead-acid Battery Program 20 Battery Memory Set and Call Out 23 System Setting 25 Battery Voltage Meter 27 Battery Resistance Meter 28 Warning and Error Message 29 The Set Contains 30 Specification 31 Conformity De
Introduction Congratulations on your choice of SKYRC T200 AC/DC Dual Balance Charger/Discharger. This unit is simple to use, but the operation of a sophisticated automatic charger such as SKYRC T200 does require some knowledge on the part of the user. These operating instructions are designed to ensure that you quickly become familiar with its functions.
Introduction Please read this entire operating manual completely and attentively before using this product, as it covers a wide range of information on operating and safety.
Special Features Dual Channel Charger SkyRC T200 allows you to charge 2 batteries with different chemistries simultaneously, and it will intelligently and automatically initiate the charging to their maximum capacity. Charging of each channel is 100Watts. Total output power of this charger is 200Watts. Optimized Operating Software SkyRC T200 features the co-called AUTO function that sets the feeding current during the process of charging/discharging.
Special Features Re-Peak Mode of NiMH/NiCd Battery In re-peak charge mode, the charger can peak charge the battery once, twice or three times in a row automatically. This is good for making the battery fully charged. Cyclic Charging/Discharging 1 to 5 cyclic and continuous process of charge > discharge or discharge > charge is operable for battery refreshing and balancing to stimulate the battery's activity.
Warning and Safety Notes These warnings and safety notes are particularly important. Please follow the instructions for maximum safety; otherwise the charger and the battery can be damaged or at worst it can cause a fire. Never leave the charger unattended when it is connected to its power supply. If any malfunction is found, TERMINATE THE PROCESS AT ONCE and refer to the operation manual. Keep the charger well away from dust, damp, rain, heat, direct sunshine and vibration. Never drop it.
Warning and Safety Notes Never attempt to charge or discharge the following types of batteries. A battery pack which consists of different types of cells (including different manufacturers) A battery that is already fully charged or just slightly discharged. Non-rechargeable batteries (Explosion hazard). Batteries that require a different charge technique from NiCd, NiMh, LiPo or Gel cell (Pb, Lead acid). A faulty or damaged battery. A battery fitted with an integral charge circuit or a protection circuit.
Warning and Safety Notes Attention should be paid to the connection of lithium battery especially. Do not attempt to disassemble the battery pack arbitrarily. Please get highlighted that lithium battery packs can be wired in parallel and in series. In the parallel connection, the battery s capacity is calculated by multiplying single battery capacity by the number of cells with total voltage stay the same. The voltages imbalance may cause fire or explosion .
Program Flow Chart BATT/PROGRAM LiPo BATT ENTER LiPo BALANCE CHG 2.0A 7.4V (2S) LiPo CHARGE 2.0A 7.4V (2S) LiPo FAST CHG 2.0A 7.4V (2S) LiPo STORAGE 2.0A 7.4V (2S) LiPo DISCHARGE 2.0A 7.4V (2S) BATT/PROGRAM LiFe BATT ENTER LiFe BALANCE CHG 2.0A 6.6V (2S) LiFe CHARGE 2.0A 6.6V (2S) LiFe FAST CHG 2.0A 6.6V (2S) LiFe STORAGE 2.0A 6.6V (2S) LiFe DISCHARGE 2.0A 6.6V (2S) BATT/PROGRAM LiIo BATT ENTER Lilo BALANCE CHG 2.0A 7.2V (2S) Lilo CHARGE 2.0A 7.2V (2S) Lilo FAST CHG 2.0A 7.
Explanation of Buttons BATT PROG / STOP Button: It is used to stop the progress or go back to previous step/screen DEC Button: It is used to go through the menus and decrease the parameter value INC Button: It is used to go through the menus and increase the parameter value ENTER / START Button: It is used to enter parameter or store parameter on screen. CHANNEL Button: It is used to switch from Channel A to B or vice versa.
Power and Battery Connection 1. Connecting to power source There are two kinds of inputs for SKYRC T200, DC 11-18V and AC 100-240V. AC 100-240V power source connection. 12V DC Battery / DC power supply connection.
Power and Battery Connection 2. Connecting the battery WARNING! TO AVOID SHORT CIRCUITS, ALWAYS CONNECT THE CHARGE LEADS TO THE CHARGER FIRST, AND THEN TO THE BATTERY. REVERSE THE SEQUENCE WHEN DISCONNECTING THE PACK. 1) LiPo Battery Connection LiPo The balance wire of the battery must be connected to the charger. Always remember to keep right polarity in the connection. Please refer to the wiring diagram above, which shows a correct way for your LiPo battery connection in the balance charge mode.
Charge Operation Charging Program Depends on different battery type, the operation programs are different. Batt Type LiPo LiHV Lilon LiFe NiMH NiCd Pb · 12 Operation Program Description CHARGE This charging mode is for charging LiPo/LiHV/LiFe/LiIon battery in normal mode. DISCHARGE This mode is for discharging LiPo/LiHV/LiFe/LiIon battery. STORAGE This program is for charging or discharging lithium battery which will not be used for long time.
Lithium Battery Program (LiPo/LiFe/Lilon/LiHV) (1) A memory profile is available for setting and storing pertinent information for up to 20 different program sets; each channel can store 10 program. Once a battery program is stored into memory, it will be retained until changed again manually. Recalling a program memory number makes the charger instantly ready to go! (2) If you do not wish to use the battery program memories, this charger can be manually set before each use.
Lithium Battery Program(LiPo/LiFe/Lilon/LiHV) BATTERY CHECK The charger is detecting the battery cell. WAIT... R shows the number of cells detected by the charger and S is the number of cells set by you on the previous screen. If the two numbers are not identical, press STOP to go back to the previous screen to recheck the number of cells of the battery pack that you set before going ahead. R:3SER S:3SER CANCEL(STOP) R:3SER S:3SER CONFIRM(ENTER) START/ENTER Lp3s 1.5A 12.
Lithium Battery Program (LiPo/LiFe/Lilon/LiHV) VARIOUS INFORMATION DURING THE PROCESS Press INC or DEC during the charging or discharging process to view further pertinent information on the LCD screen. Real-time status: battery type, battery cell count, charge Lp3s 1.5A 12.14V BAL 000:50 00022 current, battery pack total voltage,working mode, elapsed time and charged capacity. INC Voltage of each cell in the battery pack when the battery is connected with balance lead. 4.07 4.06 4.11 V 0.00 0.00 0.
NiMH/NiCd Battery Program NiMH/NiCd: This program is only suitable for charging/discharging NiMH/NiCd batteries. The T200 offers the following NiMH/NiCd charge modes: Charge, Auto Charge, Discharge, Re-Peak and Cycle. Selecting the Battery Type: After powering on the T200, press the INC or DEC button repeatedly until you reach the appropriate program for the battery type you wish to charge. For this example we have chosen the “NiMH BATT“ or “NiCd BATT” program.
NiMH/NiCd Battery Program NiMH Auto CHARGE CURRENT 1.3A START/ENTER NiMH 1.3A 5.42V AUT 002:22 00106 After selecting the correct battery type, use the INC or DEC button to change the charge mode to the “Auto CHARGE” setting. Press the START button and the amp rate value will begin flashing. Use the INC or DEC button to adjust the value to the desired rate. Follow the instructions provided on your battery when setting the upper charge amperage rate.
NiMH/NiCd Battery Program [ TIME: 00:04:04 ] 9.6V 00640mAh When discharging is complete, the screen will read “END: CUTOFF-VOL” and the charger will emit a ringing sound. The charger will display the elapsed time, end voltage and the discharged capacity in mAh. You can press the STOP button at any time during the discharging process to stop the discharge process.
NiMH/NiCd Battery Program NiMH/NiCd Cycle Mode: The T200 makes cycling of NiMH/NiCd batteries easy. The process of discharging and recharging (cycling) can be performed automatically with one simple step and will improve the performance of NiMH/NiCd batteries. We strongly recommend cycling any battery that has been discharged and stored for a period of time. This will increase the remaining usable battery life and also improve the battery performance.
Pb Lead-acid Battery Program Additional NiMH/NiCd Process Information: During the NiMH/NiCd battery charging/discharging process the T200 can display a variety of information. Using the INC or DEC buttons, you can also view the following information: NiMH Sensitivity D.Peak 4mV/CELL Delta Peak Voltage Sensitivity setting In Power Voltage 12.56V Input Voltage Ext. Temp ---Int.
Pb Lead-Acid Battery Program Pb Charge 1.5A 12.0V(6P) P-6 1.5A 13.56V CHG 002:22 00106 Press the START button again and the nominal battery pack voltage will begin flashing. Use the INC or DEC button to set the voltage and the number of cells. Press and hold the START button for 3 seconds to start charging. Once charging has commenced, the charger will display the following real-time information: battery type, charging current, battery voltage, working mode, elapsed time and charged capacity.
Pb Lead-Acid Battery Program P-6 1.5A 13.56V CHG 002:22 00106 Once charging has commenced, the charger will display the following real-time information: battery type, charging current, battery voltage, working mode, elapsed time and charged capacity. When charging is complete, the screen will read “FINISHED” and the charger will emit a ringing sound. Pb Discharge Mode: After selecting the correct battery type, use the INC or DEC buttons to change it to the “DISCHARGE“ mode.
Battery Memory Set and Call Out The charger can store up to 10 different charge/discharge profiles for your convenience, and the stored profiles can be recalled quickly without having to go through the setup process. When you are willing to alter the parameter value in the program, press START/ENTER to make it blink then change the value with INC or DEC. The value will be stored by pressing START/ENTER once. Note: All following screen are taking 2S(7.4V) LiPo battery for example. 1.
Battery Memory Set and Call Out SAVE PROGRAM SAVE . [ BATT MEMORY 1 ] L i P o 7 . 4 V ( 2 S ) Indicate the battery type and battery cell of the saved profile. [ BATT MEMORY 1 ] C:4.9A D:2.2A Indicate the charge and discharge current of the saved profile. Press the START/ENTER for 3 seconds to call out the memory. START/ENTER >3 Seconds 2. Battery Memory Call Out ENTER CHARGER LOAD Load the memory set LiPo BALANCE CHG 4.9A 7.4V(2S) Press START/ENTER for 3 seconds to start the process.
System Setting It will be operated with the default value of the essential user settings when it is powered on for the first time.The screen displays the following information in sequence and the user can change the value of parameter on each screen. When you are willing to alter the parameter value in the program, press START/ENTER to make it blink then change the value with INC or DEC. The value will be stored by pressing START/ENTER once.
System Setting SELECTION ITEM Default: 4mV/Cell 3-15mV/Cell This program is for NiMH/NiCd battery only. When the charger detects the delta peak value reaches the value you set, the charger will say the battery is fully charged. OFF/ON The beep sounds at every time touching the buttons to confirm your action. The beep or melody sounded at various times during operation to alert different mode changes. NiMH Sensitivity D.Peak Default NiCd Sensitivity D.
Battery Voltage Meter The user can check battery's total voltage, the highest voltage, the lowest voltage and each cell's voltage. Please connect the battery to the charger main battery lead to battery socket and balance wires to balance socket. This diagram shows the correct way to connect your battery to check the voltage. Lithium Battery Pack BATT/PROGRAM BATT METER Press the START/ENTER to enter the Lithium Battery Meter program. START ENTER 4.20 4.18 4.19 4.18 4.19 V 4.
Battery Resistance Meter The user can check battery's total resistance, the highest resistance, the lowest resistance and each cell's resistance. Please connect the battery to the charger main battery lead to battery socket and balance wires to balance socket. This diagram shows the correct way to connect your battery to check the resistance. Lithium Battery Pack BATT/PROGRAM BATT RESISTANCE Start Enter 012 005 005 006 mΩ mΩ Press the START/ENTER to enter the Lithium Battery Resistance program.
Warning and Error Message In case of an error the screen will display the cause of error and emit an audible sound. Incorrect polarity connected. The battery is interrupted. CONNECT ERROR CHECK MAIN PORT The battery connection is wrong. BALANCE CONNECT ERROR The balance connect is wrong. DC IN TOO LOW Input voltage less than 11V. DC IN TOO HIGH Input voltage higher than 18V. CELL ERROR LOW VOLTAGE Voltage of one cell in the battery pack is too low.
The Set Contains THE SET CONTAINS 1. SKYRC T200 Charger 2. Power Cord with EMC Ferrite Core 3. Instruction Manual EMC Ferrite Core T200 AC / DC Dual Balance Charger/Discharger Instruction Manual [Version 1.
Specification DC Input Voltage:11-18V AC Input Voltage : 100-240V Display Type: 2x16 LCD Display Backlight: Blue Case Material: Plastic Controls: Five Buttons Case Size: 178x135x96mm Weight: 850g External Port: 1-6S Balance Socket-XH, Temperature Probe Socket, Battery Socket, DC Input. Delta Peak Detection for NiMH/NiCd: 3-15mV/cell / Default: 4mV/cell Battery Cutoff Temperature: 20ºC/68ºF-80ºC/176ºF(adjustable) Charge Voltage: NiMH/NiCd: Delta peak detection LiPo: 4.18-4.25V/cell Pb Normal:2.
Conformity Declaration SkyRC T200 satisfy all relevant and mandatory EC directives and FCC Part 15 Subpart B.
Regulatory Information FCC Note: This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications or change to this equipment.
Commonly Used Terms Commonly used terms Final charge voltage: the voltage at which the battery's charge limit (capacity limit) is reached. The charge process switches from a high current to a low maintenance rate (trickle charge) at this point. From this point on further high current charging would cause overheating and eventual terminal damage to the pack. Final discharge voltage: the voltage at which the battery's discharge limit is reached.
Warranty and Service Liability exclusion This charger is designed and approved exclusively for use with the types of battery stated in this Instruction Manual. SkyRC accepts no liability of any kind if the charger is used for any purpose other than that stated. We are unable to ensure that you follow the instructions supplied with the charger, and we have no control over the methods you employ for using, operating and maintaining the device.
This content is subject to change. Latest version can be downloaded from www.skyrc.com If you have any question about this document, please contact SkyRC by sending a message to info@skyrc.cn All Rights Reserved. All specifications and figures are subject to change without notice. Printed in China 2019.