Report No.: 19PNS060103 01001 Safety Data Sheets Name of Goods: Li-ion Battery Commissioner: Dongguan Sunly Battery Technology Co., Ltd GUANGDONG UTL CO., LTD.
Page 2 of 12 Report No.: 19PNS060103 01001 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING Product Identifier Product name:Li-ion Battery Model:SL572035 , 3.7V 350mAh 1.295Wh Other means of identification Synonyms: Recommended use of the chemical and restrictions on use Recommended Use: Uses advised against: a) Do not dismantle, open or shred secondary cells or batteries. b) Do not expose cells or batteries to heat or fire. Avoid storage in direct sunlight.
Page 3 of 12 Report No.: 19PNS060103 01001 Fax:0769-87285586 Postcode:N/A E-mail address:rd-qinguofu@sunlybattery.com Emergency telephone number :136 3521 8011 Company Emergency Phone Number: +86-769-87285025 2. HAZARDS IDENTIFICATION Classification This chemical is not considered hazardous by the 2012 OSHA Hazard Communication Standard (29 CFR 1910.1200). This product is an article which is a sealed battery and as such does not require an MSDS per the OSHA hazard communication standard unless ruptured.
Page 4 of 12 Report No.: 19PNS060103 01001 EYE DAMAGE/IRRITATION (CONTINUED) Hazard category: 2B Hazard statement: Causes eye irritation Prevention:Wash thoroughly after handing. Response:If in eye: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical advice/attention.
Page 5 of 12 Report No.: 19PNS060103 01001 Product: Consisting of the following components Common Chemical Name Chemical Formula Concentration (%) CAS Number Lithium Cobalt Oxide LiCoO2 40.5 12190-79-3 Super-p C24X12 2.0 7782-42-5 -(CH2-CF2)n- 0.8 24937-79-9 Graphite C24X12 20.5 7782-42-5 Electrolyte LiPF6 20.1 21324-40-3 Copper Cu 10.4 7440-50-8 Aluminum Al 5.7 7429-90-5 Polyvinylidene Fluoride (PVDF) Note: CAS number is Chemical Abstract Service Registry Number.
Page 6 of 12 Report No.: 19PNS060103 01001 Carbon dioxide Other irritating and toxic gases. Hazardous Combustion Products Carbon oxides. Explosion Date Sensitivity to Mechanical Impact No Sensitivity to Static Discharge No Protective Equipment and Precautions for Firefighters As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear. For example: Wear self-contained respiratory protective device.
Page 7 of 12 Report No.: 19PNS060103 01001 Conditions for safe storage, including any incompatibilities If the Li-ion Battery is subject to storage for such a long term as more than 3 months, it is recommended to recharge the Lithium-ion Polymer Battery Periodically. 3 months: -10°C~ +40°C, 45 to 85% RH And recommended at 0°C~+35°C for long period storage. The capacity recovery rate in the delivery state (50% capacity of fully charged) after storage is assumed to be 80% or more.
Page 8 of 12 Report No.: 19PNS060103 01001 Tightly sealed goggles Body protection: Protective work clothing. Skin protection: Protective gloves Material of gloves: The selection of the suitable gloves does not noly depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is preparation of several substances, the resistance of the glove material can not to be calculated in advance and has therefore to be checked prior to the application.
Page 9 of 12 Report No.: 19PNS060103 01001 n-octanol/water partition coefficient Not determined. Auto-ignition temperature Product is not self-igniting. Decomposition temperature Not determined. Odout threshold Not determined. Evaporation rate Not determined. Viscosity Not determined. Other Information No further relevant information available. 10.
Page 10 of 12 Report No.: 19PNS060103 01001 Bioaccumulation potential: No further relevant information available. Mobility in soil: No further relevant information available. Results of PBT and vPvB assessment PBT: Not applicable. vPvB: Not applicable. Other adverse effects: No information available. 13. DISPOSAL CONSIDERATIONS Waste treatment methods Recommendation: Must not be disposed together with household garbage.
Page 11 of 12 Report No.: 19PNS060103 01001 Meets the requirements of 49CFR173.185 to be transported as non-dangerous goods for road, rail, air, and vessel (Effective August 6, 2014 per HM224F) The package must be handled with care and that a flammability hazard exists if the package is damaged; 15. REGULATORY INFORMATION Safety, health and environmental regulations/legislation specific for the substance or mixture EU Regulation: Authorisations: No information available.
Page 12 of 12 Report No.: 19PNS060103 01001 Photos: Fig.1 General view I of battery Fig. 2 General view II of battery GUANGDONG UTL CO., LTD. Lianding Testing Building, No.18 Center Road of Yayuan Industrial Zone, Nancheng District, Dongguan, Guangdong, China Tel:+86-769-3893 3228 Fax:+86-769-3893 3229 E-mail: sales@gdutl.