Parking Columns unlimited Manual and operational description Parking Column AS 450 PA00 Parking Column AS 450 PA00-E Parking Column AS 450 PA00-GC Parking Column AS 450 PE00 Parking Column AS 450 PE00-E Parking Column AS 450 PE00-GC Parking Column AS 450 SA00 BLL Parking Column AS 450 PA00-US Parking Column AS 450 PA00-E-US Parking Column AS 450 PA00-GC-US Parking Column AS 450 PE00-US Parking Column PE00-E-US Parking Column PE00-GC-US Parking Column SA00 BLL-US
Manual and operational description Version April 2004 Parking Columns unlimited SKIDATA AG Technical Documentation Untersbergstrasse 40 A-5083 Gartenau Telephone +43 6246 888-0, Telefax +43 6246 888-7 Internet http://www.skidata.com e-mail docu@skidata.com Copyright © 2004 by SKIDATA AG. All rights reserved. All information in the following document is protected by copyright law. No part of this document may be reproduced without the written consent of SKIDATA AG.
Manual and operational description Parking Columns unlimited Important : The FCC-specific notes apply only to the model version “AS 450 SA00 BLL-US” FC C1 5.1 9 : This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FC C1 5.
Manual and operational description Parking Columns unlimited Parking Columns unlimited 1 Document Management – Version Table Tab. 1: Document Version Table for Installation & Maintenance Instructions Section Document Pages Version 1 29 2.
1 Parking Column unlimited 1 Parking Column unlimited Version 2.
1 1.1 Parking Column unlimited Contents 1.1 Contents 1.1 Contents 1.2 1.2.1 1.2.1.
1 Parking Column unlimited System APT 450 – Columns unlimited 1.2 1.2 System APT 450 – Columns unlimited 1.2.1 Versions of Parking Column Unlimited 1.2.1.1 Parking column unlimited – “Standard” (AS 450 PA00, AS 450 PE00, AS 450 PA00US, AS 450 PE00-US) Fig. 1: Parking Column unlimited – “Standard” © SKIDATA AG, Version 2.
1 1.2 Parking Column unlimited System APT 450 – Columns unlimited 1.2.1.2 Parking column unlimited – “Extended” (AS 450 PA00-E, AS 450 PE00-E, AS 450 PA00-US, AS 450 PE00-US) Fig. 2: Parking Column unlimited - ”Extended” Page 4 © SKIDATA AG, Version 2.
1 Parking Column unlimited System APT 450 – Columns unlimited 1.2.1.3 1.2 Parking column unlimited – “Graphic” (AS 450 PA00-GC, AS 450 PE00-GC, AS 450 PA00-GC-US, AS 450 PE00-GC-US) Fig. 3: Parking Column unlimited ”Graphic” © SKIDATA AG, Version 2.
1 1.2 Parking Column unlimited System APT 450 – Columns unlimited 1.2.1.4 Parking column unlimited – “handsfree” (AS 450 SA00- BLL, AS 450 SA00 BLL-US) Fig. 4: Parking Column unlimited ”handsfree” Page 6 © SKIDATA AG, Version 2.
1 Parking Column unlimited 1.2 System APT 450 – Columns unlimited 1.2.2 Installation of Parking column unlimited 1.2.2.1 Warning General Warning: PCBs are sensitive to electrostatic discharge and should be handled with great care to avoid damage to the circuitry. Avoid touching the boards unnecessarily. Before mounting the column, check the entire device for possible transport damage. Before accessing electronical or mechanical parts, the entire deviced must be disconnected from the mains. 1.2.2.
1 1.2 Parking Column unlimited System APT 450 – Columns unlimited Fig. 5: Column installation Page 8 © SKIDATA AG, Version 2.
1 Parking Column unlimited 1.2 System APT 450 – Columns unlimited 1.2.2.4 Installation on non-level surfaces (applies only in exceptional circumstances) Fig. 6: Hexagon nuts as spacers All three No. 2 washers must be absolutely level (use a spirit level if necessary). Important: Avoid drilling dust from getting into the device during installation, as electrostatically charged dust may cause damage to the electronic assemblies inside the column. © SKIDATA AG, Version 2.
1 1.2 Parking Column unlimited System APT 450 – Columns unlimited 1.2.3 Power supply 1.2.3.1 Note Important notes: Electric installation and maintenance work may be carried out only by appropriately qualified, licensed electrical technicians. Mains connections must be hardwired. Please ensure full compliance with all applicable national and international rules and regulations concerning electric connections, and all applicable safety regulations.
1 Parking Column unlimited 1.2 System APT 450 – Columns unlimited Fig. 7: Column interior: Mounting plate configuration Ensure the following before proceeding with electrical connections: Check for proper mains supply voltage (120 or 230 VAC); see type label Mains connections must comply with national standards and directives When using flexible stranded wires, all filaments must be placed inside the terminal clamps (use wire-end sleeves, if necessary) © SKIDATA AG, Version 2.
1 1.2 Parking Column unlimited System APT 450 – Columns unlimited The mains supply line must be fused in accordance with ap- plicable regulations (6 A fuse recommended) Check the isolation resistance of the cables to make sure it exceeds 0,5 MΩ Fix cables to mounting plate by way of tension relieve tongues and cable ties Check the network cables to ensure the proper loop impedance Important: Always make sure that the device is completely disconnected from the mains while fitting electric wiring.
1 Parking Column unlimited 1.2 System APT 450 – Columns unlimited 1.2.3.3 Cross-sectional area of cable leads Tab. 1: Cable leads – Technical characteristics wires Max. torque at terminals Rigid Solid Flexible Twisted * 0,22 – 0,25 Nm 0,14 – 1,5 mm² 0,14 – 1,5 mm² ** 0,5 – 0,6 Nm 0,20 – 2,5 mm² 0,20 – 2,5 mm² *** 0,22 – 0,25 mm² 0,14 – 1,5 mm² 0,14 – 1,0 mm² 1.2.3.4 Power supply Fig. 9: Power supply on sd591 ** see Section 1.2.3.3 © SKIDATA AG, Version 2.
1 1.2 Parking Column unlimited System APT 450 – Columns unlimited Caution: The OUT terminal on connection control board sd591 is not fused and cannot be deactivated by way of the on-board mains switch.
1 Parking Column unlimited System APT 450 – Columns unlimited 1.2.3.5 1.2 Connection terminals for control lead and intercom Fig. 10: Connection terminals for control lead and intercom * see Section 1.2.3.3 © SKIDATA AG, Version 2.
1 1.2 Parking Column unlimited System APT 450 – Columns unlimited Fig. 11:Connections on control board sd582 *** siehe 1.2.3.3 Page 16 © SKIDATA AG, Version 2.
1 Parking Column unlimited System APT 450 – Columns unlimited 1.2 Fig. 12: sd582 – I/O circuit connections Note on wire twisting: When connecting Arcnet and loop cables, make sure that the wires are twisted up to the connection terminal (approx. 5 twists per 10 cm). Shield connections must be as short as possible and insulated against contact with the chassis wall by means of a protective tube. © SKIDATA AG, Version 2.
1 1.2 Parking Column unlimited System APT 450 – Columns unlimited 1.2.3.6 Loop Connections, Standard-Version, Graphics-Version, Handsfree-Version Fig. 13: Loop connections, StandardVersion, Graphics-Version, Handsfree-Version) Page 18 © SKIDATA AG, Version 2.
1 Parking Column unlimited System APT 450 – Columns unlimited 1.2.3.7 1.2 Loop connections, Extended-Version Fig. 14: Loop connections, Extended-Version) © SKIDATA AG, Version 2.
1 Parking Column unlimited 1.2 System APT 450 – Columns unlimited 1.2.3.8 Earthing connection The protective earth conductor of the lead must be attached to the central earthing point by way of a ring lug (see connection layout in Fig. 9). Fig. 15: Earthing point Fig. 16: Protective earth conductor After installation, ensure proper metal contact of all aluminium parts, i.e.
1 Parking Column unlimited 1.
1 1.2 Parking Column unlimited System APT 450 – Columns unlimited 1.2.4 Weather protection Important: Opening the device while it is exposed to rain or snowfall may cause damage to the components inside. To avoid moisture damage when performing installation work, you can protect the open device against moisture by means of an umbrella (see illustration below).
1 Parking Column unlimited System APT 450 – Columns unlimited 1.2 Fig. 18: Column top – Detail: umbrella holding frame 1.2.5 MANUAL OPEN/CLOSE switch Fig. 19: OPEN/CLOSE switch on sd591 Switch positions Position 0: Normal operation Position 1: Keep CLOSED Position 2: Keep OPEN Single gate passage Briefly set the switch to position 2; after the barrier opens, set it back to the 0 position © SKIDATA AG, Version 2.
1 1.2 Parking Column unlimited System APT 450 – Columns unlimited If no vehicle passes through the gate, the barrier will close automatically after approximately ten seconds 1.2.6 Installing devices in the front panel Fig. 20: Installing devices in the front panel Important: Devices and cables intended for subsequent installation must bear a CE label (EU countries) or UL/CSA label (USA; Canada) and must comply with all national and international standards and guidelines.
1 Parking Column unlimited System APT 450 – Columns unlimited 1.2 CAUTION: When installing devices in the front panel, ensure a minimum clearance of 5 cm above the fan-heater (see illustration). The fan-heater must never be covered to avoid the danger of fire. To avoid damage to the device, make sure that the fastening screws of the mounting plate are not screwed in too tightly (max. torque 0,5 Nm).
1 1.2 Parking Column unlimited System APT 450 – Columns unlimited Important: If the front panel is not closed tightly, water or snow may get inside the device, causing damage to the electronic assemblies. After closing the front panel, pull at it slightly to make sure it is properly closed and locked shut. Fig. 22: Closing the column top section Page 26 © SKIDATA AG, Version 2.
1 Parking Column unlimited System APT 450 – Columns unlimited 1.2.9 1.2 Installing and Deinstalling the Coding Unit (except Handsfree-Version and OEMVersion) To be able to access the Coding Unit for maintenance purposes, you must first open the front panel (see illustration). Fig. 23: Parking Column unlimited – Coding Unit The device is secured to the draw-out support plate by means of four mounting pegs (indicated by arrows in the illustration below). Fig.
1 1.2 Parking Column unlimited System APT 450 – Columns unlimited Deinstallation Before you dismount the coding unit, it is essential that you unplug all cables and disconnect the Column from the power supply Using your thumb to give you leverage, detach the front panel of the Coding Unit from the support plate (see illustration below) and lift it out of its anchoring (note that you will need to overcome a resistance to do so) Fig.
1 Parking Column unlimited 1.2 System APT 450 – Columns unlimited Fig.