DATE: May ,02, 2012 9.957.109 01 0582040 RF TRANSMITTER USE AND INSTALLATION INSTRUCTIONS Read the instructions before using the device. This control must be installed in compliance with current legislation SIT La Precisa S.p.A.
Introduction to the manual The purpose of this manual is to provide the information you need to install and use this product properly and safely. This information is the outcome of ongoing, systematic data processing and technical tests recorded and validated by the Manufacturer, in compliance with its in-house information quality and safety procedures.
See Fig. 1 and the table 1: 1 Position of room temperature sensor 2 LCD display 3 ON-OFF/PILOT Key 4 MANUAL-AUTOMATIC Key 5 UP-DOWN arrow Key 6 FUNCTION (SLEEP-PROGRAM)(*) Key or keyboard lock-release(**) 7 Base and battery compartment Note: when RF remote is associated to BIC 05844XX, where Direct Burner Ignition is present, PILOT position of the remote is equivalent to OFF position for the application.
0582040 RF TRANSMITTER USE AND INSTALLATION INSTRUCTIONS LCD Display 13 15 14 12 SLEEP MAX PROGRAM 17 11 10 18 CLOCK 19 9 8 16 MAN AUTO PILOT 19 20 23 22 21 8 Functioning mode symbols (MANUAL - THERMOSTATIC - PILOT). 9 Digits identifying the weekly TIMER program currently selected. 10 Clock setting symbol. When this symbol appears, you can adjust the clock setting displayed by the digits.
19 Selectable unit of temperature measurement (Celsius – Fahrenheit). 20 Symbol identifying room temperature measured by the built-in sensor. 21 The temperature currently measured by the remote control’s built-in sensor from the room around the remote control. 22 Low battery symbol. When this symbol disappears completely without flashing, the batteries must be replaced.
0582040 RF TRANSMITTER USE AND INSTALLATION INSTRUCTIONS Initial start-up. Preliminary operations MAX SLEEP PROGRAM Insert the 3 AAA batteries in the back battery seat (Fig. 2 and Fig. 3). CLOCK MAN AUTO PILOT MAX SLEEP SLEEP PROGRAMPROGRAM MAX CLOCK CLOCK MAN AUTO PILOT MAX SLEEP MAN AUTO PILOT PROGRAM CLOCK MAX SLEEP Fig. 3 PROGRAM Fig. 2 MAN AUTO PILOT CLOCK MAN AUTO PILOT Fig. 4 MAX SLEEP CLOCK Fig.
MAN AUTO PILOT CLOCK MAN AUTO PILOT MAN AUTO PILOT Initial start-up. Manual mode burner level selection Press and hold the "ON" button ( - Fig. 4 - ) for at least 2 seconds to enable the ignition sequence (see Section 11.5). Use the "UP" ( - Fig. 4 - ) and "DOWN" ( - Fig. 4 - ) buttons to increase or decrease the gas flow to the burner. The operation is not cyclic. In manual mode it's not possible to have a level lower than level 1. Initial start-up.
0582040 RF TRANSMITTER USE AND INSTALLATION INSTRUCTIONS MAX SLEEP PROGRAM Initial start-up. STANDBY level exit behaviour CLOCK MAX SLEEP PROGRAM When the system goes back to modulation, it proceeds as follows: The system moves to level 1 and here remains for a time tcheck_level (see "Functional parameters" table), and from this point operates according modulation algorithm, as explained at par. "Modulation". MAX MAN AUTO PILOT CLOCK SLEEP CLOCK MAN AUTO PILOT MAN AUTO PILOT Initial start-up.
0582040 RF TRANSMITTER USE AND INSTALLATION INSTRUCTIONS Weekly Programs 11.00 PM 12.00 AM 9.00 PM Week-End 10.00 PM P10 8.00 PM Workman / Clerk 7.00 PM P09 6.00 PM Workman / Clerk 5.00 PM P08 4.00 PM Workman / Clerk 3.00 PM P07 2.00 PM Workman / Clerk 1.00 PM P06 12.00 PM Shopkeeper 11.00 AM P05 9.00 AM Shopkeeper 10.00 AM P04 8.00 AM Shop 7.00 AM P03 6.00 AM Shift worker 5.00 AM P02 4.00 AM Householder 3.00 AM P01 Days 2.00 AM Program Type 1.
0582040 RF TRANSMITTER USE AND INSTALLATION INSTRUCTIONS 10 Regulatory Compliance (FCC) This equipment has been tested and found to comply with Part 15 of the FCC Rules. NOTE: Any changes or modification not approved by SIT LA PRECISA S.p.A. could void the user’s authority to operate the equipment.
0582040 RF TRANSMITTER USE AND INSTALLATION INSTRUCTIONS THIS PAGE IS INTENTIONALLY LEFT BLANK 11
0582040 RF TRANSMITTER USE AND INSTALLATION INSTRUCTIONS