SmartRelay: SREL, SREL.ZK, SREL.
SmartRelay: SREL, SREL.ZK, SREL.ADV Content 1.0 Important Information ...................................................................4 2.0 Product Description ......................................................................5 3.0 Before Ordering.............................................................................6 4.0 3.1 Determine Which Version of the SmartRelay you need.................... 6 3.2 Determine Which Accessories you need ...........................................
SmartRelay: SREL, SREL.ZK, SREL.ADV Content 8.0 9.0 7.11 Number of expansion modules ......................................................... 16 7.12 Pulse length ......................................................................................... 16 7.13 Interface ............................................................................................... 17 7.14 Restricted range.................................................................................. 17 7.
SmartRelay: SREL, SREL.ZK, SREL.ADV Page 4 1.0 Important Information Safety remark: Caution! – Incorrect handling of the batteries and storage batteries used in this product can result in the risk of fire or burns. Do not charge, open or burn these batteries or heat them to more than 100 °C (212 °F). Installation of a SimonsVoss SmartRelay requires knowledge in the areas of door mechanics, door certifications, installation of electronics and the use of the SimonsVoss software.
SmartRelay: SREL, SREL.ZK, SREL.ADV Page 5 SimonsVoss Technologies Inc. will not accept any liability for damages caused by incorrect installation. Incorrectly installed SmartRelays may block the access through a door. SimonsVoss Inc. is not liable for the consequences of incorrect installation, such as blocked access to injured or endangered persons, property damage or other damages. If you will be storing the SmartRelay for more than one week, remove the backup battery.
SmartRelay: SREL, SREL.ZK, SREL.ADV Page 6 3.0 Before Ordering 3.1 Determine Which Version of the SmartRelay you need 1. SmartRelay basic version: ordering code SREL This relay allows simple yes/no authorization for up to 8184 different transponders. 2. SmartRelay Plus version with access logging and time zones: ordering code SREL.ZK. Like the basic version, but with the capability of separately switching on access logging for the last 1024 accesses (for firmware version 4.0.01.
SmartRelay: SREL, SREL.ZK, SREL.ADV Page 7 3.4 Determine the Installation Position The range from the transponder to the SmartRelay (reader range) is a maximum of 1.5 m (5 feet), but can be dampened by a metal environment (particularly by strong magnetic fields or aluminum). Ideally, you should conduct a range test with an authorized transponder and a battery-operated SmartRelay. 3.5 4.0 Additional Information: - All cables for connecting to the SmartRelay should be type IY(ST)Y ....x0.
SmartRelay: SREL, SREL.ZK, SREL.ADV Page 8 Installation of the Backup battery Backup Batterie das the Smart Relais mit Insert the battery nur onlyeinsetzen, if you will bewenn operating SmartRelay with Netzteil bei Betrieb mit ifSREL.BAT diese the powerbetrieben supply. Dowird, not insert this battery you will be operating with nicht the SREL.BAT! Batterie einsetzen! SREL SREL and SREL.ZK und SREL.ZK +/~ -/~ C A B +V F3 F2 F1 SREL.
SmartRelay: SREL, SREL.ZK, SREL.ADV Page 9 5.0 Installation Switch off the supply voltage (if necessary, pull out the plug or disconnect the battery). Connect all cables to the terminals provided on the SmartRelay (see Connection Assignments on the following page) If you are connecting a direct current power supply, make sure that you get the polarity correct. Switch on the supply voltage (if necessary, insert the plug or connect the battery).
SmartRelay: SREL, SREL.ZK, SREL.ADV Page 10 6.0 Connection Assignments 6.1 SREL and SREL.ZK Power Netzteil { +- // ~~ Battery Batterie SREL.BAT Relais Rel { Antenna NC COM NO 1 RS 485-COM 2 RS 485-A 3 RS 485-B 4 + Vaux (3...5 V) 5 LED / Buzzer / Input 1 / CLS 6 Seriell 1 / Input 2 7 Seriell 2 Externe Einund external inputs Ausgänge and outputs Power Netzteil supply { +- // ~~ Battery SREL.
SmartRelay: SREL, SREL.ZK, SREL.ADV Page 11 6.2 SREL.ADV 6.3 Description of the SREL, SREL.ZK and SREL.
SmartRelay: SREL, SREL.ZK, SREL.ADV Page 12 7.0 Programming and Configuration When you choose SmartRelay as the locking type in the SimonsVoss software (Version 1.
SmartRelay: SREL, SREL.ZK, SREL.ADV Page 13 7.1 Access control Only possible for SREL.ZK and SREL.ADV The last 1024 transponder activation’s are saved with the date and time. 7.2 Time zone control Only possible for SREL.ZK and SREL.ADV You can load a time zone plan and the transponders are then approved or blocked, according to their time zone group. 7.3 Overlay Replacement transponders can overwrite the transponders that they replace.
SmartRelay: SREL, SREL.ZK, SREL.ADV Page 14 1. Manual locking: The door is not locked automatically according to the selected time of day, but instead only after an authorized transponder is operated after this time. 2. Automatic locking (default setting): The door is locked at exactly the time stored in the time zone plan. 3.
SmartRelay: SREL, SREL.ZK, SREL.ADV Page 15 7.7.1 The SmartRelay in OMRON Mode Authorized? Access control system Externes Zutrittskontrolloder External access control or Zeiterfassungssystem time recording system GND Release relay Freischalt Relais + 5..12VDC 1K 1K 1K Pull Up up Widerstände Pull resistors CLS Clock / D1 Data / D0 Power Netzteil { +- // ~~ F3 F2 F1 Battery SREL.BAT Batterie SREL.
SmartRelay: SREL, SREL.ZK, SREL.ADV Page 16 7.8 No acoustic programmer acknowledge Only SREL.ADV Mark this field if you want no programmer acknowledge to be given via a connected buzzer/beeper when the SmartRelay is programmed. 7.9 External beeper/ External LED Only SREL.ADV This is where you specify which external unit is connected.
SmartRelay: SREL, SREL.ZK, SREL.ADV Page 17 7.13 Interface Only for SREL.ADV For operation as a serial interface, you can select the type of card reader here that the SmartRelay should simulate. You have the following options: Wiegand 32 bit Wiegand 26 bit Primion Siemens Kaba Benzing Gantner Legic Isgus You will find the corresponding cabling information in the chapter "The SmartRelay as a Serial Interface". 7.
SmartRelay: SREL, SREL.ZK, SREL.ADV Page 18 If the current for the external component is larger than 10 mA, then this component must be fed by an external power supply. In this case, the connection should be made as follows: Ext. Netzteil External power supply GND Evtl. W iderstand zur Possibly resistor for restricting power Leistungsbegrenzung. The F3 output is max. 50 mA. Maximal + 24V Der Ausgang F3 verträgt max.
SmartRelay: SREL, SREL.ZK, SREL.ADV External access control or time recording system Page 19 8.0 Serial Interface 8.1 Functional Description In order to use a SmartRelay as a card reader in an external access control or time recording system, both the hardware (cable and signal level) and the data formats must correspond exactly to those of the card reader. Only then can the external system understand and evaluate the data from the SimonsVoss transponders.
SmartRelay: SREL, SREL.ZK, SREL.ADV Page 20 8.3 Kaba Benzing, Siemens, Gantner Legic, Primion, Isgus Interface External access control oroder time Externes Zutrittskontrollrecording system Zeiterfassungssystem GND + 5..12VDC 1K 1K 1K Pull-up resistors Pull Up Widerstände CLS Clock Data +/~ Power supply Netzteil { F2 F1 -/~ Batterie SREL.BAT Battery SREL.BAT Relay Relais { Brown White Green Grey Yellow } Externe ExternalAntenne antenna SREL.AV SREL.AV NC COM NO 9.0 Maintenance 9.
SmartRelay: SREL, SREL.ZK, SREL.ADV Page 21 9.2 Backup Battery A discharged backup battery can cause the internal clock in the type SREL.ZK or SREL.ADV SmartRelay to stop. For this reason, we recommend that you check the time of day at routine intervals. A backup battery will last approximately 10 years if there is no power supply interruption. If the SmartRelay needs the backup battery often because of frequent power failures, you should replace this battery routinely.
SmartRelay: SREL, SREL.ZK, SREL.ADV Page 22 10.0 Data sheet Housing made of black plastic: Dimensions [LxWxH] Degree of protection Temperature 72 x 57 x 25.5 mm (approximately 2.8 x 2.2 x 1.0 inches) Air humidity IP 20 (NEMA1), not tested for outside use Operation at: -31°F to +131°F (-22°C to +55°C) Storage at: 32°F to +104°F (0°C to +40°C) <95% without moisture condensation Printed circuit board dimensions [LxWxH] 50 x 50 x 14 mm (approximately 2.0 x 2.0 x 0.