Wireless Keypad: TRA.
Wireless Keypad: TRA.PINCODE Content 1.0. 1.1 1.2 2.0 2.1 2.2 2.3 GENERAL INFORMATION.................................................................................................................... 3 SAFETY REMARKS ..................................................................................................................................... 3 PRODUCT DESCRIPTION .............................................................................................................................
Wireless Keypad: TRA.PINCODE Page 3 1.0. General information Please read through these instructions in order to familiarize yourself with the functions of your Wireless Keypad. Compliance Statement (Part 15.19) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Warning (Part 15.
Wireless Keypad: TRA.PINCODE Page 4 Furthermore, please note that you should program the keypad with a PIN code immediately after you start it up. Use of a SimonsVoss Wireless Keypad requires knowledge of the use of the product and of the SimonsVoss software. For this reason, only trained and authorized personnel should program the Wireless Keypad. SimonsVoss Technologies, Inc. will not accept any liability for damages caused by incorrect programming.
Wireless Keypad: TRA.PINCODE Page 5 2.2 Operating modes The Wireless Keypad has four distinct operating modes: Mode: Explanation: Standby The Wireless Keypad is in standby mode, and uses very little power. Opening After a correct PIN has been entered, the lock is addressed via radio transmission and can be operated. Programming In this mode, the following can be programmed or reset: Battery warning 2.3 • the individual PINs (max.
Wireless Keypad: TRA.PINCODE Page 6 3.0 Start-up The first time the Wireless Keypad is installed, you will need to replace the factory-set master PIN: 12345678 with your own master PIN. Requirement: The new master PIN must • be 8 digits and • may not start with a "0" Your personal master PIN is needed to authenticate all programming processes. Choose a number that is easy for you to remember and keep it in a safe place where it cannot be accessed by unauthorized persons.
Wireless Keypad: TRA.PINCODE Page 7 4.0 Programming PINs The Master PIN required for all programming procedures is defined by the user (typically the System Administrator). Please keep this PIN safe and inaccessible to unauthorized persons, since the Master PIN enables all reprogramming of the Wireless Keypad. 4.1 First Start-up For the first start-up, the safety of your lock system requires that you program at least one PIN.
Wireless Keypad: TRA.PINCODE Page 8 4.3 Procedure Input "0" Input "master PIN" Input "1 (for PIN 1) Input "2" (for PIN 2) Input "3" (for PIN 3) Input PIN length 4, 5, 6, 7 or 8 Input "PIN" 5.0 Deleting PINs 5.1 Description To deactivate a PIN, follow these steps: 1. Press "0" to change to programming mode. 2. Enter the "master PIN ". 3. Press • "1" for "PIN 1" or • "2" for "PIN 2" or • "3" for "PIN 3". 4. For the PIN length, enter "0". 5.
Wireless Keypad: TRA.PINCODE Page 9 It is not possible to enter programming mode when there is a battery warning. This means that it is not possible to change or delete PINs when there is a weak battery. Programming mode will only be available again after you have successfully changed the battery (see the section "Battery Replacement). 5.2 Procedure Input "0" Input "master PIN" Input "1" (for PIN 1) Input "2" (for PIN 2) Input "3" (for PIN 3) Input PIN length "0" 6.0 Programming the Transponder 6.
Wireless Keypad: TRA.PINCODE Page 10 6.2 Description Generally to program a transponder using the SimonsVoss software you activate the appropriate function in the software and then it directs you to press the button on the transponder one or more times. The Wireless Keypad acts as three separate transponders and programming them requires a little more of a procedure.
Wireless Keypad: TRA.PINCODE Page 11 6.3 Procedure Input "00" Input "master PIN“ Start “Transponder programming” function in the SV software!!! Transponder 1 = press "1" button 7.0 Transponder 2 = press "2" button Transponder 3 = press "3" button Reading Transponders You can use the SimonsVoss software and configuration tool to examine the transponders integrated in the Keypad. 7.1 Description To examine the Keypad programming, proceed as follows: 1. 2.
Wireless Keypad: TRA.PINCODE Page 12 8.0 Resetting Transponders 8.1 Description To reset the transponders integrated in the Keypad, please proceed as follows: 1. 2. 3. 4. Press the "0" button twice. Enter the master PIN. Start the “Reset Transponder" function n the SimonsVoss software. For the specific transponder : • • • Transponder 1 = press "1" button, Transponder 2 = press "2" button Transponder 3 = press "3" button It is not possible to enter programming mode when there is a battery warning.
Wireless Keypad: TRA.PINCODE Page 13 9.0 Opening In order to use the Wireless Keypad to open the appropriate lock, proceed as follows: Enter a PIN that has already been programmed. You are not permitted to wait more than 5 seconds between the entries of the individual numbers. If you have entered the correct number and the integrated transponder has been programmed, the LED lights GREEN and a signal is sounded. Then the integrated transponder opens the lock. 10.
Wireless Keypad: TRA.PINCODE Page 14 11.0 Battery Warning To minimize operating errors the Wireless Keypad follows a multi-level battery warning system. When the battery capacity begins to drop, you will be notified of this in plenty of time to allow you to replace the batteries. Battery warning level 1: The opening procedure is carried out after a delay. The diode blinks YELLOW and the buzzer sounds for 10 seconds. The Keypad does not send the open command until after these 10 seconds.
Wireless Keypad: TRA.PINCODE Page 15 When replacing the batteries, be absolutely sure that no water is allowed to penetrate into the housing and that the electronics do not come into contact with water. If necessary, carefully wipe dry the housing section that is attached to the wall.
Wireless Keypad: TRA.PINCODE Page 16 13.0 Special Functions 13.1 Hidden Lock for SimonsVoss VdS Shuntlock 3066 The Wireless Keypad can be used for activating SimonsVoss activation units (VdS Shuntlock 3066). This is done by mounting the Keypad within the transmitting range of the activation unit. After you have input the correct PIN, the activation unit is addressed and the alarm system is activated or deactivated via the shuntlock.
Wireless Keypad: TRA.PINCODE Page 17 Important: Please set the two-time opening protocol (double-click) only when you are using a SimonsVoss VdS Shuntlock 3066. Otherwise, there may be malfunctions or unwanted side effects. You can switch from one configuration to the other at any time. It is not possible to enter programming mode when there is a battery warning. This means that when the battery is weak, you cannot change or delete any functions.