STRIDER PLATINUM SERIES ST75F-PT / ST65F-PT / ST55F-PT World’s smallest 80 PLUS Platinum, full-modular ATX power supplies Compact design with a depth of 140mm for easy integration High efficiency with 80 PLUS Platinum certification 100% modular cables 24/7 continuous power output with 40C operating temperature Class-leading single +12V rail Strict ±3% voltage regulation and low ripple & noise Ultra silent 120mm fan with intelligent semi-fanless operation o
SPECIFICATION SilverStone Strider Platinum SST-ST75F-PT SST-ST65F-PT SST-ST55F-PT ATX12V / EPS 12V Switching Power Supply With Active PFC 80Plus Platinum PS/2 1. General 1.1 Scope This specification defines the performance characteristics of a single phase 750, 650, 550 watts, 5 output power supply. This specification also defines worldwide safety and electromagnetic compatibility requirements for the power supply which is intended for use in computer products. 2. Input Characteristics 2.
2.3 Max. Input AC Current ST75F-PT Max. Input Current 10A Measuring Range 90 - 264 Vrms ST65F-PT Max. Input Current 10A Measuring Range 90 - 264 Vrms ST55F-PT Max. Input Current Measuring Range 8A 90 - 264 Vrms 2.4 Inrush Current The power supply must meet inrush requirements for any rated AC voltage, during turn on at any phase of AC voltage, during a single cycle AC dropout condition, during repetitive ON/OFF cycling of AC, and over the specified temperature range.
ST65F-PT Output Voltage Load MIN Range MAX Regulation Ripple & Noise P-P Max. 1. +5V 0.0A 22A ±3% 50mV 2. +12V 0.0A 54.2A ±3% 120mV 4. –12V 0.0A 0.3A ±10% 120mV 5. +5Vs 0.0A 3.0A ±5% 50mV 6. +3.3V 0.0A 22.0A ±53% 50mV Maximum continuous total DC output power should not exceed650W. Maximum continuous combined load on +3.3VDC and +5VDC outputs shall not exceed 120W. Maximum combined load on +12V outputs shall not exceed 650W.
3.3 Regulation The cross regulation defined as follows, the output regulation should be within the specified range. ST75F-PT Load +5V +3.3V +12V -12V +5Vsb Light Load. 2.44A 2.44A 10.55A 0.05A 0.51A Typical Load 6.10A 6.10A 26.38A 0.13A 1.27A Full Load 12.20A 12.20A 52.75A 0.25A 2.53A Load +5V +3.3V +12V -12V +5Vsb Light Load. 2.38A 2.38A 8.93A 0.05A 0.49A Typical Load 5.96A 5.96A 22.32A 0.12A 1.24A Full Load 11.92A 11.92A 44.65A 0.25A 2.47A Load +5V +3.
3.7 PG-OK PG-OK is a power good signal and should be asserted high by power supply to indicate that the +5 VDC and +3.3 VDC outputs are above the under-voltage thresholds of the power supply. When this signal is asserted high, there should be sufficient mains energy stored by the converter to guarantee continuous power operation within specification. Conversely, when either the +5VDC or the +3.
4.2.4 Short Circuit Protection Short circuit placed on +5V,+12V,+3.3V,-12V will latch off. +5VSB will auto-recovery. 4.2.5 Over-Current Protection Current protection should be designed to limit the current to operate within safe operating conditions.
8. Product Safety 8.1 Safety Requirement cTUVus, CB,TUV 8.2 Leakage Current The AC leakage current is less than 3.5mA when the power supply connect to 264Vac/50Hz . 8.3 Insulation Resistance The insulation resistance should be not less than 30M ohm after applying of 500VDC for 1 minute. 8.4 Dielectric Voltage Withstand The power supply shall withstand for 1 minute without breakdown the application of a 60Hz 1500V AC voltage applied between both input line and chassis (20mA DC cut-off current).
. MTBF The MTBF of the power should be 100,000 hours min. 11. Burn-In 11.1 Input Voltage Applying 220Vac for 230V model. 11.2 Test Condition Applying 75% loads for the power supply in 45 (+/-5) oC chamber for 4 hours. 12. Harmonics The product shall meet requirement for EN61000-3-2 & EN61000-3-3 :1995 standard of class D, test at 230Vac 50Hz. 13. Power Factor The power supply with active power factor correction, and meet the EN61000-3-2 standards, The power factor is greater than 0.