Users Manual RX Appendix Other Printing Methods Print using the Windows NT 4.0 LPR port TIP - The Aficio G status monitor cannot be used when printing through a LPR printer port embedded in the Windows NT 4.0. - To configure this product, you must have the Administrator rights. - In order to print using LPR, LPR port must be added. Go to Start - Settings - Control Panel Network and select Services. Click Add, select Microsoft TCP/IP Printing, and click OK. Component is installed. Restart the computer. 1.
Users Manual RX 3. Select LPR Port from the Available Printer Ports and click New Port. 4. At Name or address of server providing lpd, type in the IP address which was set to the PRICOM R9100U. At Name of printer or print queue on that server, add lp and click OK. 5. The list of Available Printer Ports will appear. Click Close. The name will be added to the Available ports. Select the appropriate port, and then click Next. 6. At Add Printer Wizard, select the printer driver to be used. Click Next.
Users Manual RX 7. Select whether to Keep existing driver (recommended) or Replace existing driver. Click Next. 8. At Printer name, type the printer name to be used in Windows NT 4.0. If necessary, type name of choice. Select to use or not use this printer as the default printer, then click Next. 9. Select Shared or Not shared according to your environment. If the printer is shared, type a share name. Click Next.
Users Manual RX 10. Select Yes, and click Finish. The new printer will be added to the list. If the test print is correct, the printer setup is complete.
Users Manual RX Print using the Windows 2000 LPR port TIP NOTE - The Aficio G status monitor cannot be used when printing through a LPR printer port embedded in Windows 2000. - To configure this product, you must have Administrator rights. - In order to print using LPR, the LPR port must be added. Go to Start - Settings - Control Panel - Add /Remove Programs - Add/Remove Windows Components and open Windows Components Wizard.
Users Manual RX 3. Select Create a new port in Select the Printer Port and create a new port. Select LPR Port and click Next. NOTE - If the destination print port was created when installing the PRICOM R-9100U, select the port from Use the following port and click Next. 4. At Name or address of server providing lpd, type in the IP address which was set to the PRICOM R9100U. At Name of printer or print queue on that server, add lp and click OK. 5.
Users Manual RX 7. At Name Your Printer, add the printer name to be used in Windows 2000. Select whether to use this printer as a default printer or not, then click Next. 8. Select Share as or Do not share this printer according to your environment on the Printer Sharing. If the printer is shared, type a share name. Click Next. 9. At the Print test page, select Yes. Click Next.
Users Manual RX 10.The information of the configuration will be listed. If there are no mistakes, click Finish. The new printer will be added to the list. If the test print is correct, the printer setup is complete.
Users Manual RX Print using the Windows XP/Windows Server 2003 LPR port TIP NOTE - The Aficio G status monitor cannot be used when printing through a LPR printer Port embedded in Windows XP, Windows Server 2003. - To configure this product, you must have Administrator rights. - The following example uses Windows XP. If you use Windows Server 2003, the screen will be different. - In order to print using a LPR, the LPR port must be added.
Users Manual RX 3. Select Create a new port in Select a Printer Port and create a new port. Select LPR Port and click Next. NOTE - If the destination print port was created when installing the PRICOM R-9100U, select the port from Use the following port and click Next. 4. At Name or address of server providing lpd, type in the IP address which was set to the PRICOM R9100U. At Name of printer or print queue on that server, add lp and click OK. 5.
Users Manual RX 7. At Name your printer, add the printer name to be used in Windows PC. Select whether to use this printer as a default printer or not, then click Next. 8. Select Share name or Do not share this printer according to your environment on the Printer Sharing. If the printer is shared, type a share name. Click Next. 9. At the Print test page, select Yes. Click Next.
Users Manual RX 10.The information of the configuration will be listed. If there are no mistakes, click Finish. The new printer will be added to the list. If the test print is correct, the printer setup is complete.
Users Manual RX Print using the Windows 2000/Windows XP Standard TCP/IP port TIP - The following example uses Windows XP. If you use Windows 2000, the screen will be different. - To configure this product, you must have Administrator rights. - For the printer port setup procedure in Windows XP SP2, refer to “Print Using a Windows Server 2003 Standard TCP/IP Port”. 1. Click start – Control Panel – Printers and Other Hardware – Add printer. The wizard for add printer appears. Click Next.
Users Manual RX 4. Click Next. 5.Type in the IP address configured on the PRICOM R-9100U in printer name or IP address. Click Next. 6. Select Custom in Device Type and click Settings.
Users Manual RX 7. Select LPR. Type in lp and check the LPR Byte Counting Enabled. Click OK. NOTE - Click OK. It will take you back to Step 6. Click Next. 8. Click Finish. 9. Select the printer driver you want to use and click Next.
Users Manual RX 10. Select Keep existing driver (recommended) or Replace existing driver. Click Next. NOTE - When installing the latest driver, select Replace existing driver. 11. Enter a name for the printer. Select Yes to make this the default printer. Click Next. 12. Select whether to Share name or Do not share this printer. If you select Share name, you can type the printer name you want to use. Click Next.
Users Manual RX 13. Select Yes to do a print test page. Click Next. 14. If the test page is printed properly, configuration is complete. Click Finish.
Users Manual RX Print using the Windows Server 2003 Standard TCP/IP port TIP - The Aficio G status monitor cannot be used when printing through a Standard TCP/IP printer port embedded in Windows 2003 server. - To configure this product, you must have Administrator rights. 1. Click start - Control Panel - Printers and Other Hardware - Add a printer. Click Next. 2. Check local printer attached to this Computer you want to use.
Users Manual RX 4. Click Next. 5. Type in the IP address configured on the PRICOM R-9100U in printer name or IP address. Click Next. 6. Click Finish.
Users Manual RX 7. Select the printer driver you want to use and click Next. 8. Select Keep existing driver (recommended) or Replace existing driver. Click Next. NOTE - When installing the latest driver, select Replace existing driver. 9. Enter a name for the printer. Click Next.
Users Manual RX 10. Select whether to Share name or Do not share this printer. If you select Share name, you can type the printer name you want to use. Click Next. NOTE - If the printer is shared with other computers in the same network, select Share name. 11. Select Yes to do a print test page. Click Next. 12. If the test page is printed properly, configuration is complete. Click Finish.
Users Manual RX Print using the Windows 2000/WindowsXP/Windows Server 2003 IPP port TIP NOTE - The Aficio G status monitor cannot be used when printing through the IPP printing function embedded in Windows 2000, Windows XP, Windows Server 2003. - To configure this product, you must have Administrator rights. - The following example uses Windows XP. If you use Windows 2000 or Windows Server 2003, the screen will be different.
Users Manual RX 3. At Specify a Printer, select Connect to a printer on the Internet or on a home or office network and assign the URL of the PRICOM R-9100U or the IP address. Click Next. - If the URL is "abc.com" http://abc.com/ipp/lp or http://abc.com/ipp -If the IP address is "192.168.20.190" http://192.168.20.190/ipp/lp or http://192.168.20.190/ipp - When using Windows 2000, a "Printer connections" window may appear. Click OK to proceed. NOTE 4.
Users Manual RX Using a Web Browser The PRICOM R-9100U has HTTP which enables you to check or change the configuration as well as checking the device status. TIP - For Web browser, we recommend Netscape Navigator 4.0 (or higher) or Internet Explorer 4.0 (or higher) version. If a different web browser is used, it must be compatible with HTTP 1.0 (RFC1945) and HTML 2.0 (RFC1866). - The information may be different depending on the products.
Users Manual RX Display Status Printer status and system information of the printer, which the PRICOM R-9100U is connected to, can be seen here. Printer Status The information for a printer connected to this product is displayed. A printer name and the status information of a printer are displayed. System Status This screen displays the status information and configuration for this product.
Users Manual RX Change the configuration Print server functions It is possible to change the configuration of this product by using a web browser. When changing the configuration of a PRICOM from a web browser, a user name and password are required. TIP Appendix - Input root for the username then click OK, or enter the password if you have created one. The default is no password (Blank).
Users Manual RX Restart Print Server The PRICOM R-9100U can be reset from the web browser. The PRICOM R-9100U is rebooted by choosing Yes on the reboot screen. Displaying our home page silex technology, Inc. (Information) The silex technology web page can be linked from the PRICOM R-9100U. If you have questions about our product, please refer to our web page.
Users Manual RX Other functions This chapter explains other functions about the PRICOM R-9100U. A web browser or TELNET is required for configuration. NOTE - For further details on how to use the PRICOM R-9100U Web browser, TELNET or the procedure to change the PRICOM R-9100U configuration, refer to "Connecting with the PRICOM R-9100U using a Web browser" or "About TELNET" in this section. IP filtering The PRICOM can define scopes of IP addresses to allow or deny communication.
Users Manual RX About TELNET After assigning an IP address to the PRICOM R-9100U, parameters can be configured with TELNET in your TCP/IP or SNMP software. TELNET allows you to display and set parameters for the PRICOM R-9100U by using the following commands. Below are some examples. - Only one PRICOM unit can be connected with a PC over TELNET. TIP NOTE - The MS-DOS Prompt or Command Prompt embedded in the Windows operating system can be used to connect with the PRICOM unit over TELNET.
Users Manual RX Display Example for Each Menu Each menu item is designed in a layered structure. (level.xx) on the upper right of the screen indicates a layer. When changing a configuration, select the number of items to be changed, and enter a parameter. When deleting a setting, and leaving the setting item blank, enter ""(two double quotations). When configuration is complete, select "99:Back to prior menu" and return to "level.1." Then select "99:Exit.
Users Manual RX Display Status menu [96] Display Status 1 : prn1 2 : system 99 : Back to prior menu Please select(1 - 99)? prn1 menu [96-1] prn1 : Ready system menu [96-2] R-9100U Version x.x.x TCP/IP status IP address Subnet Mask Gateway addr Appendix : 192.168.20.190 : 255.255.255.0 : 192.168.20.
Users Manual RX Parameter Configuration After you have finished installing the PRICOM R-9100U, you need to configure the functions. Below are the explanations on how to configure the PRICOM R-9100U. General Factory Default none (no password) AUTO Explanation Set up a password for the administrator. This password will be used for Telnet, Web page, and setup utility. Set up the LAN interface. Normally use in AUTO. If you see no blinking on the HUB after you turn on the PRICOM, change to appropriate type.
Users Manual RX Filter Mode DENY Specify the filter mode. Filter #0 Start Address Filter #0 End Address Filter #1 Start Address Filter #1 End Address Filter #2 Start Address Filter #2 End Address Filter #3 Start Address Filter #3 End Address 0.0.0.0 Specify the filter start Address. 0.0.0.0 Specify the filter end Address. 0.0.0.0 Specify the filter start Address. 0.0.0.0 Specify the filter end Address. 0.0.0.0 Specify the filter start Address. 0.0.0.0 Specify the filter end Address. 0.0.0.