CARBON MONOXIDE DETECTOR WITH BUILT IN WIRELESS TRANSMITTER Installation and Operation Manual 3126052 Model # CO5-MC(US) 418 MHZ TRANSMITTER Document # 108136
GENERAL INFORMATION: Before installing detectors, please thoroughly read these installation instructions. For detailed information on detector spacing, placement, zoning, wiring, and special applications refer to current edition of the NFPA 72 National Fire Alarm and Signaling Code. NOTICE: These instructions should be left with the owner/user of this equipment. IMPORTANT: This detector must be tested and maintained regularly following NFPA 72 requirements. Test detector operation weekly.
WHAT TO DO IF THE CARBON MONOXIDE DETECTOR GOES INTO ALARM: WARNING: Activation of your CO alarm indicates the presence of Carbon Monoxide (CO) which can KILL YOU. If Alarm sounds: 1. Operate reset/silence button; 2. Call your emergency services (_____________________) (fire department or 911); 3. Immediately move to fresh air-outdoors or by an open door/window. Do a head count to check that all persons are accounted for.
and consult the manufacturers’ instructions, or contact the manufacturers directly, for more information about CO safety and this equipment. Make sure that motor vehicles are not, and have not been, operating in an attached garage or adjacent to the residence. IMPORTANT INFORMATION FOR THE USER: CAUTION: This alarm will indicate the presence of carbon mon oxide gas at the sensor. Carbon Monoxide gas may be present in other areas.
Carbon Monoxide Gas and its Detection This carbon monoxide detector is designed for indoor use only. Do not expose to rain or moisture. Do not knock or drop the detector. Do not open or tamper with the detector as this could cause malfunction. The detector will not protect against the risk of carbon monoxide poisoning if not properly installed. The detector will only indicate the presence of carbon monoxide gas at the sensor. Carbon monoxide gas may be present in other areas.
SYMPTOMS OF CO POISIONING: Carbon Monoxide (CO) is an insidious poison. Carbon monoxide bonds to the hemoglobin in the blood and reduces the amount of oxygen being circulated in the body. It is a cumulative poison. Even low levels of CO have been shown to cause brain and other vital organ damage in unborn infants with no effect on the mother.
SOURCES OF CARBON MONOXIDE: Home appliances used for cooking and heating are the most common household Carbon Monoxide sources. Vehicles running in an attached garage can also produce dangerous levels of CO. Burning any fossil fuel including gasoline, propane, natural gas, oil, and wood can produce Carbon Monoxide. It can be produced when any heating or cooking appliance is not installed properly, vented correctly, or malfunctioning.
2. 3. 4. Extended operation of unvented fuel burning devices (range, oven, fireplace, etc.). Temperature inversions which can trap exhaust gases near the ground. Car idling in an open or closed attached garage, or near a home. GENERAL DESCRIPTION: The CO5-MC(US) is a 3V battery powered Carbon Monoxide (CO) detector with a built in wireless transmitter intended for use with Silent Call 418MHz Medallion Series Silent Buddy Receiver.
IMPORTANT: The range and proper operation of any wireless device will vary depending on its surroundings. It is very important that each CO5-MC(US) detector is tested with each receiver intended for alarm. Detector Description • LIsted to UL Standard 2034 • CO sensitivity is evaluated to UL 2034 • Local sounder • Dual LED’s • Test/Hush button • Functional Gas Test • Surface mount to wall or ceiling • Optional drywall anchors included The CO5-MC(US) contains a piezoelectric horn which generates the ANSI S3.
During initial power-up, the red and green LEDs will blink together once every 10 seconds four times. It takes about 30 seconds for the detector’s CO sensor to stabilize (see Table 1). After power-up has completed and the detector is functioning normally, the green LED blinks once every 10 seconds. The LED indication must not be used in place of the tests specified under TESTING THE DETECTOR.
Hush feature: If required, the audible alarm can be silenced for five minutes by pushing the Test button. The red alarm light will continue to flash in temp-4 pattern. If carbon monoxide is still present after the 5-minute hush period, the audible alarm will sound. The hush feature will not operate at levels above 350 ppm (parts per million) carbon monoxide. Trouble feature: When the sensor is in a trouble condition. The red LED blinks once every five seconds.
BATTERY INSTALLATION AND REPLACEMENT: You can purchase a new 3 volt Panasonic CR123A or Duracell DL123A at many different local retail stores or directly from Silent Call Communications by calling 1-800-572-5227, or online at www.silentcall.com. To replace the battery: 1. Remove the detector from its mounting base by twisting the detector counterclockwise. Remove the battery and dispose of properly. 2. To ensure proper power-down sequence, wait a minimum of 20 seconds before installing new battery. 3.
TEST BUTTON CAR BO O ON R N M CTP TE DE HUSH N RM ST O TE DE T AL DI AD B C AU T I O N : N O S M AR KING TI AC O N AL K XI GREEN LED I PA N AL AR T DO NO M RED LED 5800CO-001-V0 Figure 1: CO5-MC(US) Wireless Carbon Monoxide Detector PROGRAMMING: The CO5-MC(US) CO Detector is preprogrammed with a unique address at the Factory. You will need to follow the MINI MR1214-MC programming instructions in order to program your CO detector with your receiver.
MOUNTING THE DETECTOR: First, determine the best location for the detector, one that provides proper carbon monoxide detection (see Figure 4 for suggested detection locations) and a strong wireless transmission path. Proper Carbon Monoxide Detection Location: On a wall location, the detector should be at least as high as a light switch, and at least six inches from the ceiling. In a ceiling location, the detector should be at least 12 inches from any wall.
• • Where dirt or dust could collect and block the sensor Where it could be knocked, damaged, or inadvertently removed Good Transmission Path: A good transmission path must be established from the proposed mounting location before permanently installing the detector. To check, perform the test described in the testing signal strength section. Mounting Procedure: Once a suitable location is found, mount the detector as follows: 1.
(INSTALLED) A CK LO B E R IN ALARM A T FEATURE) NOTE A CA RBO DO PA I N N M O N OXI D DETECTOR E L MA P G: WA R N I N O T M OV E K OT NOR M C N HUSH T A O ARM TEST L AL B B MOUNTING SLOT'S ELBOW. CLOCKWISE TO LOCK 5800CO-006-V0 Figure 2. Mounting the Detector 5800CO-003-V0 Figure 3.
DO NOT attach the detector to removable ceiling panels. Attach the detector across panel support as shown in Figure 3. CAUTION: Airborne dust particles can enter the detector. Manufacturer recommends the removal of detectors before beginning construction or any other dust producing activity. Carbon monoxide detectors are not to be used with detector guards unless the combination has been evaluated and found suitable for that purpose.
Tamper Protection: The CO5-MC(US) detector includes a tamper-resistant feature that prevents removal from the mounting base without the use of a tool. To engage the tamper-resistant feature, cut the small plastic tab located on the mounting base (Figure 2), and then install the detector.
REFERENCE TABLE 1 for LED indication Mode definitions. Using a 1/8 diameter tool press and release the Test /Hush button. If the Detector is operating properly you will hear 4 quick beeps followed by 5 seconds of silence, followed by 4 more quick beeps. Red Led Blinks once a second between Temporal patterns. After second beep CO detector will reset back to Normal (standby) mode. It may take up to 30 seconds for CO detector to properly reset and be ready to retest when programming Silent Call receivers.
rotating the detector or moving the detector to another location that provides proper reception. Also be sure that the detector has been programmed and tested to the receiver in use. FUNCTIONAL GAS TEST The CO5-MC(US) has a functional gas test mode which can be used to verify the detector’s ability to sense carbon monoxide gas. NOTE: Check with local codes and the AHJ to determine whether or not a functional gas test is desired for an installation.
MAINTENANCE: It is recommended to Test and visually inspect the CO alarm Once a week. Replace CR123A Battery at least once a year to ensure proper operation of all the CO5-MC(US) functions. Make Note of the Replace CO detector by Date. CO detector has a life span of six years max. Occasionally clean the outside casing with a clean dry cloth. Ensure that the holes on the front of the alarm are not blocked with dirt and dust. Do not paint, and do not use cleaning agents, bleach, or polish on the detector.
CO Technology Limitations: The CO5-MC(US) utilizes an electrochemical CO sensing element, and therefore has certain performance limitations. The CO sensing element has a typical life of 6 years from the date of manufacture, and while the product has a timer to create a trouble condition after 6 years of operating, the date code of the product, rather than the timer, should determine when the product is replaced.
FCC INFORMATION NOTICE: Unauthorized changes or modifications could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device maynot cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation of the device.
Specifications Power Source: One 3-volt CR123A Lithium Battery (included). (Replace with Panasonic CR123A or DURACELL DL123A) These batteries are available at local retail stores. You can also order Replacement Batteries Online at www.Silentcall.com. Audible Signal (temp 4 tone): 85 dBA min. in alarm (at 10ft) 2.3 inches (58 mm) Height: 5.3 inches (135 mm) (with mounting base) Diameter: 7 oz. (241 g) (without battery) Weight: Operating Ambient Temperature Range: 40° to 100°F (4.4° to 37.
CARBON MONOXIDE DETECTOR WITH BUILT IN WIRELESS TRANSMITTER Installation and Operation Manual 3126052 Model # CO5-MC 418 MHZ TRANSMITTER Document # 108123
GENERAL INFORMATION: Before installing detectors, please thoroughly read these installation instructions. For detailed information on detector spacing, placement, zoning, wiring, and special applications refer to local building and fire codes. NOTICE: These instructions should be left with the owner/user of this equipment. IMPORTANT: This detector must be tested and maintained regularly. Test detector operation weekly. The detector should be cleaned at least once a year.
WHAT TO DO IF THE CARBON MONOXIDE DETECTOR GOES INTO ALARM: WARNING: Activation of your CO alarm indicates the presence of Carbon Monoxide (CO) which can KILL YOU. If Alarm sounds: 1. Operate reset/silence button; 2. Call your emergency services (_____________________) (fire department or 911); 3. Immediately move to fresh air-outdoors or by an open door/window. Do a head count to check that all persons are accounted for.
and consult the manufacturers’ instructions, or contact the manufacturers directly, for more information about CO safety and this equipment. Make sure that motor vehicles are not, and have not been, operating in an attached garage or adjacent to the residence. IMPORTANT INFORMATION FOR THE USER: CAUTION: This alarm will indicate the presence of carbon mon oxide gas at the sensor. Carbon Monoxide gas may be present in other areas.
Carbon Monoxide Gas and its Detection This carbon monoxide detector is designed for indoor use only. Do not expose to rain or moisture. Do not knock or drop the detector. Do not open or tamper with the detector as this could cause malfunction. The detector will not protect against the risk of carbon monoxide poisoning if not properly installed. The detector will only indicate the presence of carbon monoxide gas at the sensor. Carbon monoxide gas may be present in other areas.
SYMPTOMS OF CO POISIONING: Carbon Monoxide (CO) is an insidious poison. Carbon monoxide bonds to the hemoglobin in the blood and reduces the amount of oxygen being circulated in the body. It is a cumulative poison. Even low levels of CO have been shown to cause brain and other vital organ damage in unborn infants with no effect on the mother.
SOURCES OF CARBON MONOXIDE: Home appliances used for cooking and heating are the most common household Carbon Monoxide sources. Vehicles running in an attached garage can also produce dangerous levels of CO. Burning any fossil fuel including gasoline, propane, natural gas, oil, and wood can produce Carbon Monoxide. It can be produced when any heating or cooking appliance is not installed properly, vented correctly, or malfunctioning.
2. 3. 4. Extended operation of unvented fuel burning devices (range, oven, fireplace, etc.). Temperature inversions which can trap exhaust gases near the ground. Car idling in an open or closed attached garage, or near a home. GENERAL DESCRIPTION: The CO5-MC is a 3V battery powered Carbon Monoxide (CO) detector with a built in wireless transmitter intended for use with Silent Call 418MHz Medallion Series Silent Buddy Receiver.
IMPORTANT: The range and proper operation of any wireless device will vary depending on its surroundings. It is very important that each CO5MC detector is tested with each receiver intended for alarm. Detector Description • Local sounder • Dual LED’s • Test/Hush button • Functional Gas Test • Surface mount to wall or ceiling • Optional drywall anchors included The CO5-MC contains a piezoelectric horn which generates the ANSI S3.
CO sensor to stabilize (see Table 1). After power-up has completed and the detector is functioning normally, the green LED blinks once every 10 seconds. The LED indication must not be used in place of the tests specified under TESTING THE DETECTOR.
Table 1: Detector LED Modes Green LED Red LED Sounder Normal (Standby) Blinks every 10 seconds Off Off Alarm/Test Off Blinks every 1 second Temporal 4 Pa ern† Low Ba ery Off Blinks every 45 seconds for 37 days Chirp every 45 sec beginning 7 days a er LED blinks, con nues 30 days Dectector Trouble Off Blinks every 5 seconds One Chirp every 45 seconds Dectector End-of-Life Off Blinks every 10 seconds One Chirp every 45 seconds Power Up Blinks every 10 secs †† (w/red LED) Blinks every 10 sec
Hush feature: If required, the audible alarm can be silenced for five minutes by pushing the Test button. The red alarm light will continue to flash in temp-4 pattern. If carbon monoxide is still present after the 5-minute hush period, the audible alarm will sound. The hush feature will not operate at levels above 350 ppm (parts per million) carbon monoxide. Trouble feature: When the sensor is in a trouble condition. The red LED blinks once every five seconds.
BATTERY INSTALLATION AND REPLACEMENT: You can purchase a new 3 volt Panasonic CR123A or Duracell DL123A at many different local retail stores or directly from Silent Call Communications by calling 1-800-572-5227, or online at www.silentcall.com. To replace the battery: 1. Remove the detector from its mounting base by twisting the detector counterclockwise. Remove the battery and dispose of properly. 2. To ensure proper power-down sequence, wait a minimum of 20 seconds before installing new battery. 3.
TEST BUTTON CAR BO O ON R N M CTP TE DE HUSH N RM ST O TE DE T AL DI AD B C AU T I O N : N O S M AR KING TI AC O N AL K XI GREEN LED I PA N AL AR T DO NO M RED LED 5800CO-001-V0 Figure 1: CO5-MC Wireless Carbon Monoxide Detector PROGRAMMING: The CO5-MC CO Detector is preprogrammed with a unique address at the Factory. You will need to follow the Silent Buddy MR1110-MC programming instructions in order to program your CO detector with your receiver.
MOUNTING THE DETECTOR: First, determine the best location for the detector, one that provides proper carbon monoxide detection (see Figure 4 for suggested detection locations) and a strong wireless transmission path. Proper Carbon Monoxide Detection Location: On a wall location, the detector should be at least as high as a light switch, and at least six inches from the ceiling. In a ceiling location, the detector should be at least 12 inches from any wall.
• • Where dirt or dust could collect and block the sensor Where it could be knocked, damaged, or inadvertently removed Good Transmission Path: A good transmission path must be established from the proposed mounting location before permanently installing the detector. To check, perform the test described in the testing signal strength section. Mounting Procedure: Once a suitable location is found, mount the detector as follows: 1.
(INSTALLED) A CK LO B E R IN ALARM A T FEATURE) NOTE A CA RBO DO PA I N N M O N OXI D DETECTOR E L MA P G: WA R N I N O T M OV E K OT NOR M C N HUSH T A O ARM TEST L AL B B MOUNTING SLOT'S ELBOW. CLOCKWISE TO LOCK 5800CO-006-V0 Figure 2. Mounting the Detector 5800CO-003-V0 Figure 3.
DO NOT attach the detector to removable ceiling panels. Attach the detector across panel support as shown in Figure 3 CAUTION: Airborne dust particles can enter the detector. Manufacturer recommends the removal of detectors before beginning construction or any other dust producing activity. Carbon monoxide detectors are not to be used with detector guards unless the combination has been evaluated and found suitable for that purpose.
Tamper Protection: The CO5-MC detector includes a tamper-resistant feature that prevents removal from the mounting base without the use of a tool. To engage the tamper-resistant feature, cut the small plastic tab located on the mounting base (Figure 2), and then install the detector. To remove the detector from the base once it has been made tamper resistant, use a small screwdriver to depress the square tamper release tab, located on the skirt of the mounting base, and turn the detector counterclockwise.
REFERENCE TABLE 1 for LED indication Mode definitions. Using a 1/8 diameter tool press and release the Test /Hush button. If the Detector is operating properly you will hear 4 quick beeps followed by 5 seconds of silence, followed by 4 more quick beeps. Red Led Blinks once a second between Temporal patterns. After second beep CO detector will reset back to Normal (standby) mode. It may take up to 30 seconds for CO detector to properly reset and be ready to retest when programming Silent Call receivers.
rotating the detector or moving the detector to another location that provides proper reception. Also be sure that the detector has been programmed and tested to the receiver in use. FUNCTIONAL GAS TEST The CO5-MC has a functional gas test mode which can be used to verify the detector’s ability to sense carbon monoxide gas. NOTE: Check with local codes and the AHJ to determine whether or not a functional gas test is desired for an installation.
MAINTENANCE: It is recommended to Test and visually inspect the CO alarm Once a week. Replace CR123A Battery at least once a year to ensure proper operation of all the CO5-MC functions. Make Note of the Replace CO detector by Date. CO detector has a life span of six years max. Occasionally clean the outside casing with a clean dry cloth. Ensure that the holes on the front of the alarm are not blocked with dirt and dust. Do not paint, and do not use cleaning agents, bleach, or polish on the detector.
CO Technology Limitations: The CO5-MC utilizes an electrochemical CO sensing element, and therefore has certain performance limitations. The CO sensing element has a typical life of 6 years from the date of manufacture, and while the product has a timer to create a trouble condition after 6 years of operating, the date code of the product, rather than the timer, should determine when the product is replaced.
IC INFORMATION NOTICE: Unauthorized changes or modifications could void the user’s authority to operate the equipment. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation of the device.
Specifications Power Source: One 3-volt CR123A Lithium Battery (included). (Replace with Panasonic CR123A or DURACELL DL123A) These batteries are available at many local retail stores. You can also order Replacement Batteries Online at www.Silentcall.com. Audible Signal (temp 4 tone): 85 dBA min. in alarm (at 10ft) 2.3 inches (58 mm) Height: 5.3 inches (135 mm) (with mounting base) Diameter: 7 oz. (241 g) (without battery) Weight: Operating Ambient Temperature Range: 40° to 100°F (4.4° to 37.
DÉTECTEUR DE MONOXYDE DE CARBONE AVEC TRANSMETTEUR SANS FIL INCORPORÉ Instructions d’installation et d’emploi 3126052 MODÈLE CO5-MC TRANSMETTEUR DE 418 MHZ Document # 108123
INFORMATIONS GÉNÉRALES : Avant l’installation de détecteurs, veuillez lire attentivement ces instructions d’installation. Pour des informations détaillées sur l’espacement des détecteurs, leur position, leur câblage et leurs applications spéciales, veuillez vous reporter aux codes du bâtiment et de lutte contre l’incendie locaux. REMARQUE: Ce manuel doit demeurer en la possession du propriétaire / de l’utilisateur de l’équipement. IMPORTANT: Ce détecteur doit être testé et entretenu.
QUE FAIRE SI L’ALARME DU DÉTECTEUR DE MONOXYDE DE CARBONE EST DÉCLENCHÉE : ADVERTISSEMENT: L’activation de votre alarme de CO indique la présence de monoxyde de carbone qui peut VOUS TUER. Si l’alarme se déclenche: 1. 1) Appuyez sur le bouton de réinitialisation/ silencieux; 2. 2) Appelez vos services d’urgence (___________________) (pompiers ou 911); 3. 3) Allez immédiatement à l’air frais à l’extérieur ou près d’une fenêtre/porte ouverte.
médiat de l’équipement. Prenez note de tout matériel à combustion non inspecté par le technicien, et consultez les instructions du fabricant, ou contactez le fabricant directement, pour en savoir plus sur la sécurité du CO et de cet équipement. Vérifiez qu’aucun véhicule motorisé n’est ou n’a été en marche dans un garage joint ou adjacent à la résidence. INFORMATIONS IMPORTANTES POUR L’UTILISATEUR : ADVERTISSEMENT: Cette alarme indique la présence de monoxyde de carbone au niveau du détecteur.
Le gaz monoxyde de carbone et sa détection Ce détecteur de monoxyde de carbone est conçu pour une utilisation à l’intérieur uniquement. Ne l’exposez pas à la pluie ou l’humidité. Ne faites pas tomber et ne heurtez pas le détecteur. N’ouvrez pas le détecteur et ne l’altérez pas car il risquerait de ne pas bien fonctionner. Le détecteur ne protège pas contre le risque d’empoisonnement au monoxyde de carbone s’il n’est pas correctement installé.
SYMPTÔMES D’EMPOISONNEMENT AU CO: Le monoxyde de carbone (CO) est un poison insidieux. Le monoxyde de carbone s’agglomère à l’hémoglobine dans le sang et réduit la quantité d’oxygène circulant dans le corps. Il s’agit d’un poison à effet cumulatif. Il a été montré que même des niveaux réduits de CO sont à l’origine de cancers du cerveau et de dommages à d’autres organes vitaux chez les enfants à naître sans effet sur la mère.
SOURCES DE MONOXYDE DE CARBONE: Les appareils domestiques utilisés pour la cuisson et le chauffage sont les sources les plus courantes de monoxyde de carbone domestique. Les véhicules en marche dans un garage attenant peuvent également produire des niveaux de CO dangereux. La combustion de tout combustible fossile comme l’essence, le propane, le gaz naturel, le pétrole et le bois peut produire du monoxyde de carbone.
2. Le fonctionnement prolongé d’appareils à combustion non ventilés (cuisinière, four, cheminée, etc.). 3. Des inversions de température susceptibles de piéger les gaz d’échappement près du sol. 4. La marche au ralenti d’un moteur de voiture dans un garage attenant ouvert ou fermé, ou à proximité d’une maison.
IMPORTANT: La portée et le bon fonctionnement de tout appareil sans fil dépendent de son environnement. Il est très important que chaque détecteur CO5-MC soit testé avec chaque récepteur devant servir d’alarme.
Lorsqu’il est allumé et que le détecteur fonctionne normalement, le voyant vert DEL clignote une fois toutes les 10 secondes. L’indicateur DEL ne doit pas être utilisé au lieu des tests mentionnés dans la rubrique relative au TEST DU DÉTECTEUR.
Tableau 1 : Modes du détecteur DEL Voyant DEL vert Voyant DEL rouge AverƟsseur sonore Normal (aƩente) Clignote toutes les 10 secondes Éteint Éteint Alarme/Test Éteint Clignote toutes les secondes Séquence T4 † Pile presque épuisée Éteint Clignote toutes les 45 secondes pendant 37 jours Émet un peƟt bruit toutes les 45 sec à compter de 7 jours après le DEL intermiƩent, conƟnue pendant 30 jours Problème de détecteur Éteint Clignote toutes les 5 secondes Émet un peƟt bruit toutes les 45 secon
Mode silencieux: Si nécessaire, l’alarme audible peut être mise en mode silencieux pendant cinq minutes en appuyant sur le bouton Test. Le voyant rouge d’alarme continuera à clignoter en suivant une séquence T4. S’il reste encore du monoxyde de carbone après le délai de silence de 5 minutes, l’alarme audible retentit. La fonctionnalité de silencieux ne fonctionnera pas à des niveaux de plus de 350 ppm (parties par million) de monoxyde de carbone.
INSTALLATION ET REMPLACEMENT DE LA PILE: Les piles 3 volts Panasonic CR123A ou DL123A peuvent être achetées dans différents magasins de détail locaux ou directement auprès de Silent Call Communications en appelant le 1-800-572-5227, ou en ligne à www.silentcall. com. Pour remplacer la pile : 1. 1. Retirez le détecteur de son support de montage en le faisant tourner dans le sens contraire des aiguilles d’une montre. Retirez la pile et éliminez-la comme il convient.
BOUTON DE TEST CA R BO O ON R N M CTP TE DE HUSH N RM ST O TE DE T AL DI AD B C AU TI O N : N SO M A R K IN G TI AC ON K AL XI VOYANT DEL VERT I PA N AL A T DO NO RM VOYANT DEL ROUGE 5800CO-001-V0 Figure 1: Détecteur de monoxyde de carbone sans fil CO5-MC PROGRAMMATION: Le détecteur de CO CO5-MC est préprogrammé à l’aide d’une adresse unique en usine.
MONTAGE DU DÉTECTEUR: Tout d’abord, déterminez le meilleur emplacement pour le détecteur, il doit permettre de bien détecter le monoxyde de carbone (voir la Figure 4 pour en savoir plus sur les emplacements suggérés pour la détection) et une bonne transmission du signal sans fil. Emplacement approprié pour la détection du monoxyde de carbone: Sur un mur, le détecteur doit être au moins à la hauteur d’un interrupteur d’électricité, et au moins à six pouces (15 cm) du plafond.
• • • • Dans ou sous un placard Dans un endroit où la circulation de l’air serait obstruée par des rideaux ou des meubles Dans un endroit où la poussière ou la saleté peuvent s’accumuler et obstruer le détecteur Dans un endroit dont il peut tomber, où il peut être endommagé ou retiré par inadvertance Transmission sans obstacle: On vérifiera que le signal peut être transmis à partir de l’emplacement d’installation proposé avant de l’installer de manière permanente.
VIS DE MONTAGE (INSTALLÉ) A LO CK B O C G: I WA R NI N O T M OV E K N AL ARM A L T N M O N OX D ET ECTOR PA I N CA RB O MA ONGLET ANTI-ALTÉRATION (COUPEZ LE PETIT ONGLET POUR ACTIVER LA FONCTIONNALITÉ ANTI-ALTÉRATION) I DE DO OT N OR L N H US H M R M T A E AR T EST P AL B REMARQUE SERVEZ-VOUS DE L’EMPLACEMENT DES VIS A PUIS FAITES A OU B EN FONCTION DES BESOINS, TOURNER LA BASE ET SERREZ LES VIS AU NIVEAU DU COUDE DE CHAQUE FENTE DE MONTAGE ENGAGEZ L’ENCOCHE AVEC L’ONGLE
N’ATTACHEZ PAS le détecteur à des panneaux amovibles du plafond. Attachez le détecteur sur le panneau comme le montre la Figure 3 ATTENTION: Les particules de poussière en suspension dans l’atmosphère peuvent entrer dans le détecteur. Le fabricant recommande de retirer les détecteurs avant de commencer des travaux de construction ou toute autre activité productrice de poussière.
Protection contre l’altération: Le détecteur CO5-MC est équipé d’une fonctionnalité résistant à l’altération qui empêche son retrait du support d’installation sans l’utilisation d’un outil. Pour installer la fonctionnalité anti-altération, coupez la languette de plastique située sur le support d’installation (Figure 2), et installez le détecteur.
TABLEAU DE RÉFÉRENCE 1 pour les définitions des modes d’indication DEL. À l’aide d’un outil de 1/8 de diamètre, appuyez et relâchez le bouton Test /Silencieux. Si le détecteur fonctionne correctement, vous entendez 4 bips rapides suivis par 5 secondes de silence, suivies par 4 bips plus rapides. Le voyant rouge clignote une fois par seconde entre les séquences. Après le deuxième bip, le détecteur de CO se remet en mode normal (attente).
meilleure. Vérifiez également que le détecteur a bien été programmé et testé en fonction du récepteur que l’on utilise. TEST DE GAZ FONCTIONNEL Le CO5-MC est équipé d’un mode de test de gaz fonctionnel qui peut permettre de vérifier la capacité du détecteur à déceler la présence de gaz monoxyde de carbone. REMARQUE : Consultez les codes locaux et l’autorité compétente pour déterminer si convient de procéder à un test de gaz fonctionnel pour une installation.
MAINTENANCE: On recommande de tester et d’inspecter visuellement le système d’alarme au CO une fois par semaine. Remplacez la pile CR123A au moins une fois par an pour garantir le bon fonctionnement de toutes les fonctions du CO5-MC. Prenez note de la date de remplacement du détecteur de CO. Sa durée de vie maximale est de six ans. Nettoyez occasionnellement le boîtier extérieur avec un chiffon propre et sec.
Limitations de la technologie CO: Le CO5-MC utilise un élément de détection électrochimique CO, et a donc certaines limites de performance. L’élément de détection de CO a une durée de vie type de 6 ans à compter de la date de fabrication. Il est programmé pour indiquer une alerte après six ans de fonctionnement, mais c’est le code de date du produit, plutôt que ce programme, qui doit déterminer le moment du remplacement du produit.
AVIS D’INFORMATION IC: Toute modification non autorisée pourrait annuler autorisation votre d’utiliser l’équipement. Cet appareil est conforme avec Industrie Canada exemptes de licence RSS ou les normes. Son fonctionnement est sujet aux deux conditions suivantes: (1) cet appareil ne doit pas émettre de brouillage nuisible, et (2) cet appareil doit accepter toute interférence reçue, y compris les interférences pouvant entraîner un fonctionnement indésirable du dispositif.
Specifications Source d’alimentation : Une pile au lithium de 3 volts CR123A (livrée avec l’appareil). (Remplacez-la par une pile Panasonic CR123A ou Duracell DL123A) Ces piles peuvent être achetées dans de nombreux magasins de détail locaux. Vous pouvez également commander des piles de rechange en ligne à www.silentcall.com. Signal audible (tonalité T4) 85 dBA min. en alarme (à 10 ft, 3 m) 2,3 pouces (58 mm) Hauteur: 5,3 pouces (135 mm) avec support de montage Diamètre: 7 oz.