SIGNAMAX Networks 065-1180 FiberPack Media Converter Rack Mount Chassis Signamax Connectivity Systems RS-232/422/485 to 100BaseFX Multimode / Singlemode Fiber Converter Model 065-1163F series U S E R ’ S G U I D E
Signamax Connectivity Systems RS-232/422/485 to 100BaseFX Multimode / Singlemode Fiber Converter Model 065-1163F series User’s Guide
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter FCC Warning This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter Trademarks Product names mentioned in this manual may be trademarks or registered trademarks of those products and are hereby acknowledged. • Ethernet is a trademark of Xerox Corporation. • Microsoft Windows Corporation. • Signamax TM Connectivity Systems is a trademark of Advanced Electronic Support Products, Inc.
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter T ABLE OF CONTENTS CHAPTER 1: INTRODUCTION… … … … … … … … ..1 PRODUCT OVERVIEW .................… … … … … … … . 1 FEATURES .................… … … … … … … … … … … … 3 SPECIFICATION.................… … … … … … … … .… .. 4 PACKAGE CONTENTS.................… … … … … … … . 5 CHAPTER 2: INSTALLATION… … … … … … … .… . 6 DTE & DCE SWITCH SETTING..........… … … … … … 7 CONNECTION TO DATA TERMINAL EQUIPMENT (DTE)… … … … .....
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter 1 INTRODUCTION Product Overview Thank you for selecting the Signamax RS-232/422/485 to 100BaseFX Media Converter. This converter is designed to provide a RS-232/422/485 point-t o-point connection over fiber optic cable where the connected devices employ a RS-232/422/485 interface.
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter (RS-232/422/485 to Multimode Fiber Converter, ST) (RS-232/422/485 to Multimode or Singlemode Fiber Converter, SC) Introduction 2
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter Features • Complies with EIA/TIA and IEEE standards • Supports 4-wire full-duplex asynchronous serial data transmission (RS-422/485) • Supports 2-wire half-duplex asynchronous serial data transmission (RS-485) • Supports serial port asynchronous data rates up to 115.2 Kbps • Extended distances up to 1.
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter Specifications Standards: IEEE 802.3u (100BaseFX Fast Ethernet); EIA/TIA RS-232E; EIA/TIA-574 Ports: 1x duplex fiber; ST Multimode (065-1163FST) 1x duplex fiber; SC Multimode (065-1163FSC) 1x duplex fiber; SC Singlemode (065-1163FSM) 1x 9-pin serial connector; D-sub, female Data Rates: Fiber: 100 Mbps Serial: 50 ~ 115.2 kbps (asynchronous). Max.
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter Power: AC power adapter; 12V DC @ 0.8A Frequency: 47Hz to 63Hz. Environment: Operating: Temperature: 32°F to 131°F (0°C to 55°C) Relative Humidity: 10% to 80%, non-condensing Non-Operating/Storage: Temperature: -13°F to 158°F (-25°C to 70°C) Relative Humidity: 5% to 90%, non-condensing Emissions: FCC Part 15 of Class A & CE approved Dimensions: 2.9 x 4.3 x 0.9 inches [W x D x H] (73.8 x 109.2 x 23.4 mm) Weight: 5.
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter Optical Data: Model Type Fiber (µm) Wavelength Connector Type MT 62.5/125 1300nm ST MC 62.5/125 1300nm SC SC 9/125 1310nm SC SC-30 9/125 1310nm SC TX PWR (min, max) -20, -14 dBm -20, -14 dBm - 20, -14 dBm -15, -7 dBm RX Sensitivity PWR Budget (min, max) 11, 17 dB Typical Distance -31 dBm 11,17 dB 2km -31 dBm 11,17 dB 20km -34 dBm 19, 27 dB 30km.
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter 2 INSTALLATION To ensure proper installation of the converter, please note the following procedures: • • • • • DB9 Female Connector Pin Assignment Serial Connection Connection to DTE Connection to DCE Connection to Fiber Optic Cable DB9 Female Connector Pin Assignment Pin 1 2 3 4 5 6 7 8 9 RS-232 RS-422/485 (Full4-wire duplex) (Full-duplex) DCD RX RX+ TX TX+ DTR GND GND DSR RTS RXCTS TXRI RS-485 2-wire (Half-duplex) **DATA B(+)
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter Serial Connection This converter features DIP switches on the rear panel that sets the unit to the correct type of cable configuration to support connection with a RS-232/422/485 device. For setting the control function of the serial port, see the table below: DIP 1** ON OFF Serial Connection RS-232 Console Data Communication NOTE: Default/factory setting is “ON” position.
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter Connection to Data Terminal Equipment (DTE) Console Mode 1. Ensure that DIP switch #1 is in the “ON” position. (Enables Console mode) 2. Set DIP switches #2, #3 and #4 according to wire type as indicated below: RS-232 4-wire (RS-422/485) 2-wire (RS-485) DIP 2 ON OFF DIP 3 OFF ON DIP 4 OFF OFF OFF OFF ON 3. Prepare TIA/EIA-574 compliant ‘cross-over’ shielded cables with DB-9 connectors. 4.
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter Data Communication Mode 1. Ensure that DIP switch #1 is in the “OFF” position. (Disables Console mode) 2. Set DIP switches #2, #3 and #4 according to the wire type, as indicated below: RS-232 4-wire (RS-422/485) 2-wire (RS-485) DIP 2 ON OFF DIP 3 OFF ON DIP 4 OFF OFF OFF OFF ON 3. Set DIP switch #7 to the “OFF” position for RS -232 application. (“ON” position for RS-422/485 applications). 4.
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter Connection to Data Communication Equipment (DCE) Data Communication Mode 1. Ensure that DIP switch #1 is in the “OFF” position. (Disables Console mode) 2. Set DIP switches #2, #3 and #4 according to the wire type, as indicated below: RS-232 4-wire (RS-422/485) 2-wire (RS-485) DIP 2 ON OFF DIP 3 OFF ON DIP 4 OFF OFF OFF OFF ON 3. Set DIP switch #7 to the “OFF” position for RS -232 applications.
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter Connection to Fiber Optic Cable When connecting fiber cable to the 100BaseFX port of the media converter, be sure the correct type – SC or ST connector is used. Follow the steps below to properly connect the fiber cable: 1. Remove and keep the SC/ST port’s rubber cover. When not connected to a fiber cable, the rubber cover should be replaced to protect the optics. 2. Check that the fiber terminators are clean.
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter 3 LED INDICATORS This converter has several LED indicators that enable quick identification of the status of the converter as well as what is happening across your network. Their functions are as follows: PWR Power: Green light indicates normal operation. LNK/ACT Link/Activity: Flashing green light indicates that the converter is receiving link pulses from compliant devices.
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter 4 Configuration There are two separate methods for configuring this media converter for use. In the first section of this chapter, the Command line Interface (CLI) or Menu-driven interface via the Console Port to set the device for connection to data terminal equipment in console mode will be defined. The second section will describe the CLI or Menu-driven via Telnet configuration.
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter password. After successful login, type the following command line to change the device IP address in CLI mode where xxx’s represent values between 0 and 254, and the user should enter their own IP address in this form. • set eth0 ip xxx.xxx.xxx.xxx 2. After entering the new IP address. The system will confirm whether the operation is successful. NOTE: Copy the new address down on a piece of paper.
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter proceed. 5. Select either the CLI User Interface or the Menu-driven Interface option by using the associated number key or using the TAB key and pressing ENTER. A Main Menu screen appears. Main Menu Configuration Options The figure below shows the Main Menu screen. From this screen the configuration options available provide the user to quickly access and adjust the media converter settings as required.
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter DHCP Configuration Menu DHCP (Dynamic Host Configuration Protocol) allows the converter to obtain an IP address from the DHCP server automatically. NOTE: A DHCP server must exist and be available in your local network prior to enabling the DHCP client. RS232 Transfer and Serial Port Configuration Menu The RS232 Transfer menu is applicable to all RS-232, RS-422, and RS -485 modes.
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter through a media converter, it is necessary to set up a connection between the local and remote media converter. The connection setup process involves the server waiting for a connection service request sent by the client. During this process, the default setting is AUTO mode wherein the system will determine which end is the server and which end is the client automatically.
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter Under the Serial Port Configuration heading, the field Operation Mode is a “read only” value indicating one of the following modes: Console, RS -232, RS -422, or RS-485. The mode is based on the DIP switches setting found on the rear panel of the media converter. Other fields that can be modified from this screen are: communication data baud rate, parity, word length, stop bits and flow control.
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter field and enter the IP address of the TFTP server in the IP address field to perform the upgrade. Load System Default The Load System Default command allows a user to restore factory default settings to the converter. From the Main Menu, highlight the Load System Default field and hit the key to execute.
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter with other devices with the same defaults. NOTE: Prior to following the instructions listed below for Remote Computer Login, ensure that a serial cable connection between the media converter and remote workstation exists. Remote Computer Login 1. The default Login name is “admin” with no preset password.
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter 4. Press ENTER and on the following screen, type the default username admin, leave the password field blank since there is no default value, and press ENTER to proceed. 5. Select the CLI User Interface option by using the associated number key or using the TAB key and pressing ENTER. A command prompt appears. NOTE: Type “?” or “help” to view full list of commands and explanations.
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter Command Definitions backup: Use this command to save configuration settings to file. exit: Type exit or logout and press ENTER to quit the program. help: To access help commands list. ping: Type ping followed by a space, and then the IP address of the device to send a test signal. If a response is received, then the device is connected. To view a full list of ping options, type ping and press ENTER.
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter communication is idle set xfer – the command is for RS232 configuration and data communication setting. The command syntax is as shown below: set xfer [arg_1 data_1] [arg_2 data_2] ... [arg_n data_n] [Argument List] idle........... Set idle time of serial port type… … … Set operation type (AUTO, SERVER or CLIENT) remote...... Set remote IP address port........... Set TCP port number baud......... Set baud rate of serial port parity.
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter and filename accurately. upgrade firmware: Use this command to load new versions of software for this console. For example: upgrade firmware firmware.bin Configuration xxx.xxx.xxx.
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter A APPENDIX A RS-232 Wiring Male-to-Female Wire (DTE->DTE): RS-232 (DTE) DB9 Female PIN 1 PIN 2 PIN 3 PIN 4 PIN 5 PIN 6 PIN 7 PIN 8 PIN 9 ? ? ? ? Ground ? ? ? ? PC-COM1 (DTE) DB9 Male PIN 1 PIN 3 PIN 2 PIN 6 PIN 5 PIN 4 PIN 8 PIN 7 PIN 9 Male-to-Male Wire (DTE->DCE): Converter DB9 Female PIN 1 PIN 2 PIN 3 PIN 4 PIN 5 PIN 6 PIN 7 PIN 8 PIN 9 ? ? ? ? Ground ? ? ? ? Appendix A DCE Device DB9 Female PIN 1 PIN 3 PIN 2 PIN 6 PIN 5 PIN
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter B APPENDIX B RS-422/485 4-Wire Definition Converter DB9 Female PIN 1 PIN 2 PIN 3 PIN 4 PIN 5 PIN 6 PIN 7 PIN 8 PIN 9 RS-422/485 Device ? ? A (RX+) B (TX+) ? ? C (RX-) D (TX-) RS-485 2-Wire Definition Converter DB9 Female PIN 1 PIN 2 PIN 3 PIN 4 PIN 5 PIN 6 PIN 7 PIN 8 PIN 9 RS-422/485 Device ? 1 (B+) ? 2 (A-) Appendix B 27
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter C APPENDIX C Application Examples • DTE to DTE DTE DTE 2km 62.5/ 125um FIBER 1200m RS-485 CABLE PC • RS-485 Converter Push-button set to DTE 1200m RS-232 CABLE RS-485 Converter push-button set to DTE PC DTE to DCE DTE 2km 62.
Signamax 065 -1163 F series RS-232/422/485 to 100BaseFX Media Converter D CONTACT INFORMATION SIGNAMAX CONNECTIVITY SYSTEMS An AESP Company 1810 N.E. 144th Street. North Miami, Florida 33181, U.S.A. Phone: 305-944-7710 Fax: 305-652-8489 Sales: 800-446-2377 Tech. Support: 800-446-2377, ext. 201 Http://www.signamax.com E-mail: info@signamax.com EUROPE AESP Ukraine. (UKRAINE) 2 Timiryazevskaya St. 47 252014 Kiev, Ukraine Phone: +380 44 296.53.57 Fax: +380 44 294.88.60 Http://www.aesp.com.