Guaranty and Declaration Copyright SIGLENT TECHNOLOGIES CO., LTD All Rights Reserved. Trademark Information SIGLENT is the registered trademark of SIGLENT TECHNOLOGIES CO., LTD Declaration SIGLENT products are protected by patent law worldwide. SIGLENT reserves the right to modify or change parts of or all the specifications or pricing policies at company’s sole decision. Information in this publication replaces all previously corresponding material.
General Safety Summary Carefully read the following safety precautions to avoid any personal injury or damage to the instrument and any products connected to it. To avoid potential hazards, please use the instrument as specified. Use proper power cord Only the power cord designed for the instrument and authorized by local country could be used. Ground the instrument The instrument is grounded through the protective earth conductor of the power cord.
Keep product surfaces clean and dry. To avoid the influence of dust and moisture in the air, please keep the surface of the device clean and dry. Do not operate in wet conditions. In order to avoid short circuiting to the interior of the device or electric shock, please do not operate the instrument in a humid environment. Safety terms and symbols Terms on the product. These terms may appear on the product: Indicates direct injuries or hazards that may happen.
Contents Guaranty and Declaration ....................................................................................................................................... I General Safety Summary ........................................................................................................................................ II General Inspection ................................................................................................................... ..............................
Contents Inspect the shipping container Keep the shipping container or cushioning material until the contents of the shipment have been completely checked and the instrument has passed both electrical and mechanical tests. The consigner or carrier will be responsible for damages to the instrument resulting from shipment. SIGLENT will not provide free maintenance or replacement.
The Front Panel Adjust the supporting legs For benchtop operation, you may want to use the supporting legs. Adjust the supporting feet appropriately to tilt the RF signal source upwards. Figure 1- 1 Before adjusting Figure 1- 2 After adjusting Connect to AC power supply The RF signal source accepts 100-240V, 50/60/440Hz AC power supply. Please use the power cord provided in the accessory to connect the instrument to the power source as shown in the figure below.
Preparing for Use 1 2 3 4 9 8 7 6 5 5 Figure 1- 4 the Front Panel 5 Table 1 1 Front Panel Description 3 5 NO. Description NO.
The Front Panel Front panel function button Table 1 2 Function keys description Control Keys Description FREQ Set frequency, frequency offset, phase offset and other related parameters LEVEL Set level, level offset, ALC state, flatness and other parameters, power sensor display and control functions SWEEP Set sweep state, step sweep, list sweep, direction and other related parameters LF Set LF state, LF level, LF frequency and other related parameters MOD Set various modulation parameters (AM, FM
Digital keyboard The front panel of the RF signal source provides a numeric keypad (as shown below). The keyboard supports English uppercase and lowercase characters, numbers, and common symbols (including decimal points, spaces, and !, @, #,$, %, ^, &, *), mainly for editing the name of files or folders and setting parameters (refer to the "parameter setting" section). Control Keys 0 Digit 0 and space bar switch *...# In the English state, enter the special symbol !, @, #,$, %, ^, &, *.
Direction knob and keys operation 1. Direction knob In the non-parametric input state, turn the knob to move the focus frame in sequence. Press the knob in the function area to enter the next level menu bar. Press the knob in the parameter input area, the cursor will focus to a certain position, and then turn the knob to change the value. 2. Direction keys In the non-parametric input state, press the up, down, left and right direction keys to move the focus frame in sequence.
Front panel connectors 1. LF output 1 Output for the LF (low frequency) signal. This is a BNC connection. The output can also be configured to source the modulation waveform for FM and PM modulation types. 2. Radio frequency output terminal 2 RF signal output N-type connector with an impedance of 50 ohms.
Rear Panel 11 10 1 0 12 13 14 15 16 17 18 19 9 8 7 6 5 4 3 2 1 Figure 1- 7 Rear Panel SSG5000X Signal Generator 8
1. AC power input terminal The RF signal source can operate with AC power from 100 V - 240 V, at 45 Hz - 440 Hz. Please connect the RF signal source to the AC power supply with the supplied power cord. connector, it will use it as an external reference source. At this point the user interface status bar shows "Ext Ref".
High level (3.3 V): Indicates that the RF signal is being configured. Low level (0 V): Indicates that the RF signal is stable (effective). 14. Q_OUT Output the analog, in–phase component of I/Q modulation from the internal baseband generator when the internal IQ modulation mode is on. 10. TRIG IN/OUT When PULSE trigger mode is "Int ", the connector can be used to output the trigger signal.
1 2 3 4 Figure 1- 8 User Interface 11 SSG5000X Signal Generator
User Interface 1. Prompt status bar Display LOCAL (local), REMOTE (remote). When REMOTE is displayed, the instrument is being controlled by a remote computer and the front panel inputs will be locked. To unlock (LOCAL mode), press Esc/Close. EXT REF: EXT REF shows that the SSG is using an external 10 MHz reference. LF: Low frequency signal generator state. MOD: The modulation state. RF: The RF output state. SWEEP: The status of the sweep state.
4. Touch screen display area: Display the settings under each menu LF: LF output state and LF waveform displayed. Sine, Square, Sawtooth, Triangle and DC can be set up. ANALOG MOD: Modulation state. Amplitude modulation, frequency modulation, phase modulation, or pulse can be set. RF: RF output state. Frequency, level or RF Sweep can be set. IQ MOD: I/Q output state. IQ modulation can be set. UTILITY: System and file related parameters can be set. Power Sensor: Power sensor state.
Firmware Operation Check System Information Firmware Upgrade Pres Utility -> including: Follow this procedure to update the instrument firmware: System Info to view the instrument's system information, Startup Times 1. Download the firmware package from an official SIGLENT website. Model www.siglentamerica.com Software Version http://www.siglent.com/ens Hardware Version https://www.siglenteu.com Host ID 2. Extract and copy the .ADS file into the root directory of a USB stick.
Touch Operation The RF signal source provides a 5-inch capacitive touch screen to support various gesture operations, including: Click on the screen parameters or menu to edit the parameters. Left or right slide switches menus. Up and down slides the display menu. Help Information The built-in help system provides help information for each function and menu option on the front panel. Press UTILITY pop up to help. button and select help.
Remote Control The generator supports communication with compatible computers via USB, LAN, and GPIB-USB interfaces. By using these interfaces, in combination with programming languages and/or NI-VISA software, users can remotely control the signal generator. More information can be found in the SSG5000X Programming Guide available on the SIGLENT website. For More Product Information You can obtain the instrument information and installation status of all options through [UTILITY] System Info.
Contact SIGLENT America SIGLENT Technologies America, Inc 6557 Cochran Rd Solon, Ohio 44139 Tel: 440-398-5800 Toll Free:877-515-5551 Fax: 440-399-1211 info@siglent.com www.siglentamerica.com Headquarters SIGLENT TECHNOLOGIES CO., LTD. Blog No.4 & No.5, Antongda Industrial Zone, 3rd Liuxian Road, Bao’an District, Shenzhen, 518101, China. Tel:+ 86 755 3688 7876 Fax:+ 86 755 3359 1582 sales@siglent.com www.siglent.