en 1. 1.1 1.2 1.3 1.4 1.5 2. 2.1 2.2 3. 4. 4.1 4.2 4.3 4.4 4.5 4.6 5. 6. 6.1 6.2 6.3 7. 7.1 7.2 Modification of Input-Output identification string 20 7.3 Alarm notification enabling ................................. 22 7.3.1 IN1 closed alarm...................................... 22 7.3.2 Temperature alarm.................................. 22 7.4 Digital I/O status................................................. 24 8. ENVIRONMENTAL COMPATIBILITY AND DISPOSAL ..... 25 English INTRODUCTION .................
en English 1. Introduction Thank you for choosing this product. Please read this manual carefully to optimize use of the TEL50.GSM. 1.1 Copyright Siemens S.p.A. All rights reserved. The reproduction, modification or transcription of this document without prior written authorization is forbidden except as allowed under the copyright laws. Copyright© 2005 1.2 Trademarks TEL50.GSM is a Siemens S.p.A. registered trademark. Building Technologies -1- TEL50.
1.3 Declaration of conformity Siemens S.p.A. Building Technologies Viale Piero ed Alberto Pirelli, 10 - 20126 Milano (MI) Italy declares on its sole responsibility that the following product: TEL50.GSM complies with the regulations in force with reference to the R&TTE 99/5/EC directive and, above all, with the following standards: Health and Safety (Art. 3.1 a) EN 60950 EMC (Art. 3.1 b) EN 301 489-1/-7 RF spectrum efficiency (Art. 3.2) EN 301 511, EN 300 607-1 Building Technologies -2- TEL50.
1.4 Warranty This product is guaranteed against any material and manufacture defects. SIEMENS reserves the right, at its own discretion, to repair or replace faulty products. The warranty is deemed null and void if the fault is caused by improper use or by an operating procedure that is not included in this manual. The warranty will not cover faults caused by: • improper and careless use • damage caused by atmospheric agents • acts of vandalism • material that is subject to wear and tear 1.
2. Instructions In order to use the product safely and efficiently, please read the following instructions carefully before use. The product may only be employed for the use for which it has been conceived and manufactured. Any other use shall be considered the user’s sole responsibility. 2.1 Safety instructions Installation, programming and commissioning should only be carried out by qualified operators; these operators must be physically and mentally capable of performing the task.
Precautions: Do not install and use the product in close proximity to electromedical equipment without checking that this is permitted. During operating, the product may cause interference to transceiver equipment such as televisions, radios, PCs. Move the product so that there is no more interference. Hearing aids or pacemakers or other personal medical devices may be subjected to interference when the device is in operation. Consult your doctor for further information.
2.2 Operating instructions 1. The SIM Card must always be inserted and removed when there is no power supply. If not, the SIM Card read interface inside the GSM module could be damaged. 2. Always disable the PIN code of the SIM card. If not, the TEL50.GSM cannot be enabled. Do this using a normal mobile phone. SIM card (non included) could be for voice traffic only. However we recommend using SIM cards that are also enabled for data traffic. 3.
3. General information The TEL50.GSM phone remote control has been designed for remote operation of electrical or electro-hydraulic equipment such as room thermostats, boilers, burners, heaters, zone valves, circulation pumps, irrigation systems, etc. It is particularly suitable for holiday home installations where there is no fixed telephone network. The remote control can only be used through the GSM mobile network.
4. Installation Comply with the permitted temperature and humidity conditions (see Technical Data). 4.1 Wall-mounting Mount the device on the wall or 3-module flush-mounted box (503 type) using the special holes in the rear part of the container. During installation, be careful not to damage the internal components. 4.2 Electrical connections To make the electrical connections, remove the plastic cover of the TEL50.GSM: when you have finished, remember to put the cover back into position.
Connecting terminals. + - + - Power supply input. Only use the supplied power supply. Use of incompatible power supplies may cause irreversible damage to the device. Check the correct polarity. OUT2 OUT1 1 1 2 IN 1 1 2 OUT1 - Relay output 1 Potential-free relay contact for control of special devices (boiler, zone valve, heater, etc.). Observe the max current rating of the electrical contacts indicated in the technical data.
230 V AC Power supply input: 12VDC - 1A L Button for local activation of relay outputs B1 + - - 1 N 2 3 4 5 TEMP TEL50.GSM IN 1 OUT 2 1 2 1 2 REV.... OUT 1 1 2 CI T1 T2 - + Alim. L + L SIM card holder L1 N1 M M1 S1 L1 N E1 V1 OUT2 OUT1 1 1 2 2 IN 1 1 2 TEMP 1 2 3 4 5 Legend Alim = Stabilized power supply 230/12VDC 1A CI = TEL50.GSM telephone remote control Relay output 2 N1= REV..
4.3 Connection of stilo antenna The TEL50.GSM is supplied with its own dual band stilo antenna with the following characteristics: PARAMETER CHARACTERISTICS Profile 900MHz band 1,800MHz band Impedance WSVR Type Radiation diagram on horizontal plane Radiation diagram on vertical plane Connector Dual-Band GSM 890-960MHz 1710-1,880MHz 50 ohm <= 1:1,5 Omnidirectional Circular @ ± 0.5dB ± 35° @ 3dB SMA (male) 4.4 Connection of external antenna (optional) In the top part of the TEL50.
Recommendations for use of fixed or external antenna You are advised to observe the following recommendations: • The antenna must be placed at least 2m from any electronic equipment, at least 15cm from any obstacles and in a position where there is good reception. • If malfunctioning or interference to the local electrical equipment occurs during use of the TEL50.GSM, reposition the device / antenna. • Do not use the stilo antenna if the TEL50.GSM is used in enclosed or particularly shielding environments.
4.6 Checking of indicator lamps The TEL50.GSM has 5 LED indicator lamps. Three of these can be seen on the front of the device and the other two are located in the lower part and can be seen through the plastic grid.
5. Technical data Power supply Average consumption Alarm input Temperature sensor input Length of temp.
6. Basic configuration With the factory configuration, the TEL50.GSM can already handle the following voice (DTMF tones) and SMS commands. In order to operate safely and correctly, the device must be correctly connected to the GSM network (see par. 4.6). Carefully check that this is the case during installation and before leaving the device’s final location. ABC 6.1 Commands via DTMF tones Ensure that the calling telephone is enabled to send DTMF tones (multifrequency).
When the “#” tone is received, if the command is effected, the sequence of corresponding beeps (ON or OFF) is generated. If the command is not recognized or is not applicable (for example, if an ON command is sent to an input “31#”), the ERROR tone is generated. If the “? ” tone is received, the OFF tone is generated as confirmation of the command. Call the telephone number for the TEL50.GSM and wait for the device to answer (a beep after the first ring).
SMS text SMS reply Action OUT1=1 OUT1=1 closes contact relay 1 OUT1=0 OUT1=0 opens contact relay 1 OUT2=1 OUT2=1 closes contact relay 2 OUT2=0 OUT2=0 opens contact relay 2 OUT1 OUT1=0 or OUT1=1 (*) queries the status of contact relay 1 – OUT1=0 contact open OUT1=1 contact closed OUT2 OUT2=0 or OUT2=1 (*) queries the status of contact relay 2 – OUT2=0 contact open OUT2=1 contact closed IN1 IN1=0 or IN1=1 (*) queries the status of alarm input - IN1=0 contact open IN1=1 contact closed (*) Note: with factory
7. Extended configuration Using the basic configuration already present, the user can customize device parametrization by changing some of the system parameters via SMS. Carefully note any changes made and keep them with these instructions in order to ensure that the device is correctly controlled even after a long period of time or by other qualified users. 7.
[USER] SMS command SMS reply Action USER USER01=3351234567.1 USER01=3351234567.1 User USER01 set as Administrator USER USER02=3471234567.2 USER02=3471234567.2 User USER02 set as User USER USER03=3291234567.3 USER03=3291234567.3 User USER03 set as Notify USER USER20=3201234567 USER20=3201234567 User 20 set as Notify USER USER01 USER01=3351234567.
7.2 Modification of Input-Output identification string In this section the User can modify the identification string (ALIAS) for the device inputs/outputs. If no changes are made, the factory settings are maintained. The defined alias will have a maximum length of 10 alphanumeric characters ( 0÷9, A÷Z ). Observe the syntax indicated below. Note that the characters “space (blank), +, -, _, etc”, are not included and, consequently, are not recognized by the device.
[ALIAS] SMS command ALIAS IN1 ALIAS OUT1 ALIAS IN1= ALIAS OUT1= SMS reply Action IN1=ALARM OUT1= BOILER IN1 deleted OUT1 deleted querying of IN1 input identification string querying of OUT1 output identification string cancels IN1 input identification string (resets IN1 string) cancels OUT1 output identification string (resets OUT1 string) Caution.
7.3 Alarm notification enabling The TEL50.GSM can handle the following alarms: - Contact IN1 closed alarm - Temperature threshold exceeded alarm 7.3.1 IN1 closed alarm This alarm may come from any device whose status needs to be monitored (eg. home alarm system, boiler burner block, etc.). A potential-free contact must be used. When the contact is closed, an SMS is sent to all the users on the USER list.
Example: SMS command allarme SMS reply Action ALARM=5 RESET=6 alarm threshold set to 5°C reset threshold set to 6°C ON TEMP ALARM=5 TEMP RESET=6 impostazione di fabbrica OFF 5 6 temp. 19 20 temp. allarme SMS command SMS reply Action TEMP ALARM=20 TEMP RESET=19 ALARM=20 RESET=19 alarm threshold set to 20°C reset threshold set to 19°C ON OFF Alarm notification is automatically enabled when the ALARM and RESET thresholds are set.
7.4 Digital I/O status In this section, the idle and/or operating condition of the digital input IN1 and relay outputs OUT1 and OUT2 can be redefined. The factory setting has the following conditions: - The alarm input IN1 is active high, ie.
8. Environmental compatibility and disposal This product has been developed and constructed using materials and processes that take account of environmental issues. Refer to the following notes for disposal of the product at the end of its service life or if it needs to be replaced: • • • • For disposal purposes, this product is classified as an electrical and electronic device: do not dispose of it as household waste especially as far as the printed circuit is concerned.
Building Technologies - 26 - TEL50.