Preface RUGGEDCOM WIN5158-AC-IS Installation Guide TBD RC1253-EN-01 Introduction 1 Installing the Device 2 Technical Specifications 3 Dimension Drawings 4 Certification 5
RUGGEDCOM WIN5158-AC-IS Installation Guide Copyright © 2016 Siemens Canada Ltd. All rights reserved. Dissemination or reproduction of this document, or evaluation and communication of its contents, is not authorized except where expressly permitted. Violations are liable for damages. All rights reserved, particularly for the purposes of patent application or trademark registration. This document contains proprietary information, which is protected by copyright. All rights are reserved.
RUGGEDCOM WIN5158-AC-IS Installation Guide Concord, Ontario Canada, L4K 5C7 iii
RUGGEDCOM WIN5158-AC-IS Installation Guide iv
RUGGEDCOM WIN5158-AC-IS Installation Guide Table of Contents Table of Contents Preface ............................................................................................................... vii Alerts ................................................................................................................................................ vii Related Documents ............................................................................................................................
Table of Contents RUGGEDCOM WIN5158-AC-IS Installation Guide Chapter 4 Dimension Drawings .......................................................................................... 27 Chapter 5 Certification ........................................................................................................ 29 5.1 Standards Compliance ............................................................................................................... 29 5.2 Agency Approvals ..........................
RUGGEDCOM WIN5158-AC-IS Installation Guide Preface Preface This guide describes the RUGGEDCOM WIN5158-AC-IS. It describes the major features of the device, installation, commissioning and important technical specifications. It is intended for use by base station installers and operators, and assumes readers have a working knowledge of WiMAX technologies and procedures. While some safety precautions are reviewed here, it is assumed that installers are trained in safe installation practices.
RUGGEDCOM WIN5158-AC-IS Preface Installation Guide Training Siemens offers a wide range of educational services ranging from in-house training of standard courses on networking, Ethernet switches and routers, to on-site customized courses tailored to the customer's needs, experience and application.
RUGGEDCOM WIN5158-AC-IS Installation Guide Chapter 1 Introduction Introduction The RUGGEDCOM WIN5158-AC-IS Outdoor Unit (ODU) Customer Premises Equipment (CPE) device is part of the RUGGEDCOM WIN family, a line of mobile WiMAX broadband wireless access systems based on the IEEE 802.16e mobile WiMAX standard. The RUGGEDCOM WIN5158-AC-IS is a high-performance, self-learning subscriber.
Chapter 1 Introduction RUGGEDCOM WIN5158-AC-IS Installation Guide Section 1.1 Feature Highlights Long Range The device has multiple built-in receivers to improve range and Non-Line-of-Sight (NLoS) performance. The system has the ability to leverage sub-channelization technology to balance links with high-power base stations. Robust Design The device is designed for mission critical applications in harsh environments with very high Mean Time Before Failure.
RUGGEDCOM WIN5158-AC-IS Chapter 1 Installation Guide Introduction Section 1.2 Configuration Ports and Indicator LEDs Connectors and LED indicators are found on the bottom of the device casing. RUGGEDCOM WIN5158-AC-IS 2 1 3 4 Figure 1: RUGGEDCOM WIN5158-AC-IS Connectors 2. ANT2 1. ANT1 3. Ground 4.
Chapter 1 RUGGEDCOM WIN5158-AC-IS Introduction Installation Guide LED Color Description RSSI: one LED is ON (least significant) Green RSSI < -90 RSSI: two LEDs are ON Green -85 < RSSI < -90 RSSI: three LEDs are ON Green -80 < RSSI < -85 RSSI: four LEDs are ON Green -75 < RSSI < -80 RSSI: five LEDs are ON Green -70 < RSSI < -75 RSSI: six LEDs are ON Green -65 < RSSI < -70 Older Hardware LEDs 1-7: Green LED 8: Red RSSI: seven LEDs are ON Latest Hardware LEDs 1-6: Green -20 < RSSI <
RUGGEDCOM WIN5158-AC-IS Chapter 1 Installation Guide Introduction Module Description Antenna or Antennas: Dual omni or polarization antennas supporting MIMO schemes. 4 2 1 3 Figure 2: RUGGEDCOM WIN5158-AC-IS CPE Block Diagram: External Antennas 1. Power Supply 2. RF 3. Base-Band 4. Antennas Outdoor Grounding System Verify the antenna or cable system is grounded. The CPE antenna installation must be as per Article 810 of the NEC.
Chapter 1 RUGGEDCOM WIN5158-AC-IS Introduction Installation Guide Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.
RUGGEDCOM WIN5158-AC-IS Installation Guide Chapter 2 Installing the Device Installing the Device This chapter describes how to install the device, including mounting the device, connecting power, connecting the antenna, and connecting the device to the network. DANGER! Electrocution hazard – risk of serious personal injury and/or damage to equipment.
Chapter 2 Installing the Device RUGGEDCOM WIN5158-AC-IS Installation Guide IMPORTANT! Install equipment in accordance with the electrical code relevant to the country of installation, such as: • the National Electrical Code (NEC), ANSI/NFPA 70 • the Canadian Electrical Code (CEC), Part 1, CSA C22.
RUGGEDCOM WIN5158-AC-IS Chapter 2 Installation Guide Installing the Device NOTE For detailed dimensions of the device, refer to Chapter 4, Dimension Drawings. The following sections describe the various methods of mounting the device, and how to install the mounting bracket: • Section 2.1.1, “Mounting the Device to a Pole” • Section 2.1.2, “Mounting the Device to a Wall or Tower” The RUGGEDCOM WIN5158-AC-IS ODU CPE mounting kit allows for pole or wall mounting.
Chapter 2 RUGGEDCOM WIN5158-AC-IS Installing the Device Installation Guide 2 3 1 2 8 9 10 2 4 61 5 7 5 6 Figure 3: Mounting the Antenna/Enclosure to a Large Pole 1. Pole Nut 2. Clamping Bracket 3. Mounting Bracket 4. M8-25 Hex Screw 8. M8-70 Hex Screw 9. M8 Spring Washer 10. M8 Flat Washer 5. M8 Flat Washer 6. M8 Spring Washer 7. M8 3 1 2 10 2 4 5 6 7 6 5 8 9 Figure 4: Mounting the Antenna/Enclosure to a Small Pole 1. Pole 2. Clamping Bracket 3. Mounting Bracket 4.
RUGGEDCOM WIN5158-AC-IS Chapter 2 Installation Guide 5. Installing the Device Tighten the screws connecting the clamping bracket to the mounting bracket. Make sure the screws are torqued to 14 N·m (10 lbf-ft). Section 2.1.2 Mounting the Device to a Wall or Tower Attach the device to any wall capable of carrying the device's weight. An outer wall on a roof or other high location to avoid interference from other buildings or trees is preferred.
Chapter 2 Installing the Device 8. RUGGEDCOM WIN5158-AC-IS Installation Guide Tighten the screws connecting the arm bracket to the device and mounting bracket. Make sure the screws are torqued to 24 N·m (17.7 ft. lb.). Section 2.2 Installing the Antenna To install the antenna, do the following: WARNING! Radiation hazard – risk of Radio Frequency (RF) exposure. This base station is compliant with the requirements set forth in CFR 47, section 1.
RUGGEDCOM WIN5158-AC-IS Chapter 2 Installation Guide 3. Installing the Device Position the device until the maximum RSSI link quality reading is achieved. A single RSSI LED indicates the device is at minimum synchronized with the base station. For information about the RSSI LED indicators, refer to Section 1.2, “Configuration Ports and Indicator LEDs”. If the device is not synchronized with the base station, make sure all parameters are configured properly.
Chapter 2 RUGGEDCOM WIN5158-AC-IS Installing the Device Installation Guide 1 2 38 mm (1.5 in) Figure 7: Cutting the Jacket 1. Wire Jacket 3. 2. Foil Fold the foil back over the wire jacket. 1 2 3 Figure 8: Folding Back the Foil 1. Foil 4. 2. Twisted-Pair Wires 3. Drain Wire Bend the drain wire back over the jacket. 1 2 3 Figure 9: Bending the Drain Wire 1. Foil 5. 14 2. Drain Wire 3. Twisted-Pair Wires Partially untwist each wire pair, making sure to retain a half twist at the end.
RUGGEDCOM WIN5158-AC-IS Chapter 2 Installation Guide Installing the Device Figure 10: Untwisting the Wire Pairs 6. Arrange the wires according to the following pin-out description: Pin Number Color 1 White/Orange ETH Data TP0+ 2 Orange ETH Data TP0- 3 White/Green ETH Data TP1+ Figure 11: CAT-5e PoE Cable Pin-Out 4 Blue 48 V TP2+ 1. Pin 1 5 White/Blue 48 V TP2- 6 Green ETH Data TP1- 7 White/Brown RTN (-) TP3+ 8 Brown RTN (-) TP3- 2 1 7. 2.
Chapter 2 RUGGEDCOM WIN5158-AC-IS Installing the Device Installation Guide 12. Trim away any excess foil or drain wire extruding from the strain relief. 13. Slide the connector components up to the plug body. 14. Insert the modular plug into the plug housing. 1 2 3 Figure 13: Assembling the Connector Components 1. PoE Plug 2. Plug Housing 3. Dust Cover 15. Align the latch with the LATCH slot. 16. Press the plug into the plug housing until it bottoms out. 17.
RUGGEDCOM WIN5158-AC-IS Chapter 2 Installation Guide Installing the Device A single output RJ45 connector provides 10/100 Base-T data and power to the outdoor unit over a Category 5e cable. This cable provides for the bi-directional transfer of data and signaling as well as a power feed to the outdoor equipment. NOTE The Category 5e Ethernet cable is not included. Refer to Section 3.5, “IDU to ODU Cable Specifications” for detailed technical specifications.
Chapter 2 RUGGEDCOM WIN5158-AC-IS Installing the Device Installation Guide Section 2.5 Connecting to a RUGGEDCOM RP100 or RP110 (AC Only) The RUGGEDCOM RP100 and RP110 are optional power injectors that can be ordered to power the RUGGEDCOM WIN5158-AC-IS. The RUGGEDCOM RP100 and RP110 meet a wider temperature and voltage range than the WIN1010. When the CPE is connected to a RUGGEDCOM RP100 or RP110, make sure there is a solid connection between the lightning protector and the CPE.
RUGGEDCOM WIN5158-AC-IS Chapter 2 Installation Guide Installing the Device Section 2.6 Installing the Device in Hazardous Locations An approved surge suppression unit is required when the base station is installed in a hazardous location. The WIN5158-AC-IS is certified for installation in Class I, Division II Groups A, B, C and D hazardous locations when installed using the Class I, Division II kit (P/N MKIT0090).
Chapter 2 RUGGEDCOM WIN5158-AC-IS Installing the Device Installation Guide 2. Using a CAT-5e cable, connect the PoE injector to the CPE. 3. Using a CAT-5e cable, connect the Ethernet switch to the PoE injector. CAUTION! The AC power cable must consist of 3 wires, be minimum 18 AWG, be less than 4.5 m (14.7 ft) long, and be safety certified according to national rules. 4. Connect the AC open-ended power cable to the Lambda PSU. Section 2.
RUGGEDCOM WIN5158-AC-IS Chapter 2 Installation Guide Installing the Device 2. Make sure the connection is secure and the cable extends below the connector to provide a path for water to flow away from the base station. 3. Starting as close to the base station as possible, stretch and wind rubber splicing or self-amalgamating tape around the connector and cable. Make sure there are no gaps. Continue wrapping until the tape is 25 mm (1 in) down the cable.
Chapter 2 Installing the Device RUGGEDCOM WIN5158-AC-IS Installation Guide Figure 20: Sealing Gaps with Putty Section 2.9 Configuring the CPE Once the CPE is installed and connected to the network, it must be configured. The RUGGEDCOM WIN5158AC-IS features a Web-based User Interface (UI) for all configuration management. For more information about configuring the base station, refer to the RUGGEDCOM WIN CPE User Guide associated with the device and the installed software release.
RUGGEDCOM WIN5158-AC-IS Chapter 3 Installation Guide Technical Specifications Technical Specifications The following sections provide important technical specifications related to the device: • Section 3.1, “Power Supply Specifications (AC Only)” • Section 3.2, “Power Consumption” • Section 3.3, “Operating Environment” • Section 3.4, “Mechanical Specifications” • Section 3.5, “IDU to ODU Cable Specifications” Section 3.
Chapter 3 RUGGEDCOM WIN5158-AC-IS Technical Specifications Installation Guide Parameter Range Ambient Relative Humidity 5% to 95% Ambient Storage Temperature -40 to 75 °C (-40 to 167 °F) Comments Non-condensing Section 3.4 Mechanical Specifications Parameter Value Dimensions Refer to Chapter 4, Dimension Drawings Weight 1.5 kg (3.3 lb) Enclosure Aluminum Ingress Protection IP67 Section 3.5 IDU to ODU Cable Specifications Special 4×2×24 AWG FTP Cat.
RUGGEDCOM WIN5158-AC-IS Chapter 3 Installation Guide Technical Specifications Insulation O.D.: 1.07 mm Color Code: Per TIA/EIA 568-B Overall Foil Shield: Yes Overall Shield Material: Aluminum/Polyester Foil Overall Foil Design: 100% Coverage Overall Drain-wire Material: Tinned Copper Overall Drain-wire Size: 24 AWG Overall Drain-wire Construction: Stranded Inner Jacket Material: UV resistant FR-PVC Inner Jacket Diameter: 6.
RUGGEDCOM WIN5158-AC-IS Installation Guide IDU to ODU Cable Specifications Chapter 3 Technical Specifications 26
RUGGEDCOM WIN5158-AC-IS Chapter 4 Installation Guide Dimension Drawings Dimension Drawings NOTE All dimensions are in millimeters, unless otherwise stated. Overall Dimensions (WIN5158-AC-IS-AC) 71.2 80.1 69.5 25.1 79.6 15.5 29.8 44.2 92.2 154 241.4 226 249 11 36 4.
Chapter 4 RUGGEDCOM WIN5158-AC-IS Dimension Drawings Installation Guide Overall Dimensions (WIN5158-AC-IS-DC) 98.3 97.9 15.5 71.2 44.2 11 154 241.3 226 253.7 36 92.
RUGGEDCOM WIN5158-AC-IS Chapter 5 Installation Guide Certification Certification The RUGGEDCOM WIN5158-AC-IS ODU CPE has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. • Section 5.1, “Standards Compliance” • Section 5.2, “Agency Approvals” • Section 5.3, “MIL-STD Ratings” • Section 5.4, “IEEE 802.16e Mobile WiMAX Compliance” • Section 5.5, “Environmental Type Tests” Section 5.
Chapter 5 RUGGEDCOM WIN5158-AC-IS Certification Installation Guide Agency Standards Comments FCC FCC Part 90 Approved CE ETSI EN 301489-1/4, ETSI EN 302 326-1/2/3 Approved IC RS197 Approved IC SRSP 301.7 issue 2 Approved ETSI ETS 300 019 Approved UL/CSA Class I Div II, UL 1604, CSA 22.2 No213-M1987 Approved ATEX Zone 2 EN60079-0, EN60079-15 Approved AREMA Designed to meet and exceed AREMA C&S Manual part 11.5.1 as applicable. Section 5.
RUGGEDCOM WIN5158-AC-IS Chapter 5 Installation Guide Certification Test Description Test Levels Duration: 16h IEC-60068-2-14 TEMP CHANGE -10 to 45 °C 0.5 °C/min Duration: 2 cycles IEC 60068-2-30 HUMIDITY (Cycling) 30°C 90-100% Duration: 2 cycles IEC 60068-2-18 WATER: Rain (intensity) 0.01m3/min, 90kPa, 30min IEC-60068-2-64 RANDOM ASD - 0.04 m²/s3³ Class 4M5 VIBRATION (4M5) IEC 529 (IP65/IP67) 12 -12 dB /oct Freq.
Chapter 5 RUGGEDCOM WIN5158-AC-IS Certification Installation Guide Test Description Test Levels Duration: 72h IEC-60068-2-2 HIGH TEMP 55 °C Duration: 72h IEC 60068-2-30 HUMIDITY (Cycling) 30°C, 90-100% Duration: 2 cycles IEC-60068-2-6 SINE Velocity: 5 mm/s VIBRATION Displacement: 1.